Baltech 10089200A03B User Manual

Operation Manual

RFID Reader “IDE-XG-125-USB”
REVISION 2.0, 2013-12-04
Confidential information, all rights reserved.
Lilienthalstraße 27
85399 Hallbergmoos
Germany
Phone: +49 (811) 99 88 1- 0
FAX: +49 (811) 99 88 1- 11
e-mail: info@baltech.de
http://www.baltech.de/
Covered Variants:
10089-200
10089-2x
1-y1
IDE-XG-125-USB
1
“x“ and “y” shall represent any numerical number.
- 1 -

Introduction

The “10089-2XY” is a contactless desktop smart card USB reader and writer which supports all major 125 kH z family cards.

Mounting and Connection

The reader generates a magnetic field at 125 kHz frequency which could be influenced by any electrically conductive material close to the device. To ensure good performances and functionalities in terms of read range and reliability a minimum distance of 10cm from such materials is required. Mounting the unit directly to metal would result in a severe reduction of read range down to zero functionality. Care should be taken when testing the device after mounting at a problematic environment: Read ranges and performance vary from card to card and very much from card to tag or key-fob.
When mounting multiple readers, the distance between readers should be minimum 0.5 m in order to avoid degradation of performance due to interference.
To connect the device to a host system (a printer or a PC), please make sure that the system provides an USB socket intended for connection of the reader.

Operation

Whenever the device is connected to the USB-Host, it will switch on the internal antenna and periodically scan for a card. Once a card has been detected, the card number is read, the data converted and sent to the host system through the USB Interface. To enable the device to read cards, tags and key-fobs successfully, they should be placed centred above the reader.
- 2 -
Parameters
Descriptions
LEDs, Buzzer
Pin
Name
Type
Description
1
PWR
Power
5V Power Supply
2
D-
Output
USB-Data inverted
3
D+
Input
USB-data
4
GND
Power
Signal and Power Ground
Technical Features
RF-Characteristics
Interfaces
Power
Temperature
Humidity
Operated Frequencies 125KHz
Data transmissi on
modulation reader to card:
Data transmissi on
modulation card to reader:
Host USB: Full speed 2.0
Human
Supply [VDC] USB bus powered: 5 (±5%)
Consumption [W] 0.5 typ
Operating [°C] -20 to +65
Storage [°C ] -25 to +85
Operating[%]
Non Operating [%]
ASK
AM/Load modulation
20 to 80 relative humidity; non condensing
10 to 90 relative humidity; non condensing

Pinout 4-Pin USB-A plug and Signal Descriptions

- 3 -

General regulatory requirements

FCC ID OKY10089200A03B IC: 7657A- 10089200
NOTICE: This device complies with Part 15 of the FCC Rules and with Industry Canada licence­exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Changes or modifications made to this equipment not expressly approved by BALTECH AG may void the FCC authoriz ati on to oper at e this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protecti on ag ai nst harm ful i nterference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipm ent off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
- 4 -
Loading...