Analog Sensors
BAW M08EI-UAD15B-BP03
M 8
Sl = 0,5...1,5 mm
0...10V
shielded
Common Data
Mounting in steel shielded
Linearity range Sl mm 0,5...1,5
Rated operating distance Se mm 1
Repeat accuracy ± 8 µm
Linearity
Limit frequency (-3dB) 1000 Hz
Measuring velocity
Response time 0,5 ms
Temperature coefficient TK typ. -1 µm/K
in optimized range min. -0,5 µm/K
from +10...+50°C max. -2 µm/K
Max. non-linearity % ±3% from Ua max.
Max. working range shift mm ±0,1
Adjusting indication nein
Ambient temperature range °C -10...+70
IEC-Code |1A08SA1
Time delay before availability ms <1ms
≤ ± 30 µm
20 m/s
≤
Approvals
Utilization categories DC 13
Insulation class II
If not differently indicated,
all values by IEC 947-5-2
(DIN EN60947-5-2)
Specifications subject to change
Mechanical Data
Housing size mm cyl. M 8
Measurements BxHxT or DxT mm M8x1 x 51,5
Housing material stainless steel
Material of sensing face PBTP
Degree of protection IP IP67
Connection Cable
Cable type LifYY-O 3x0,14mm² 3m lang
Electrical Data
Current type DC
Wiring 3-Wire
Output signal 0...10V
Rated operational voltage V 24 DC
Rated insulation voltage Ui V 250 V AC
Ripple % <= 15% from Ue
Output resistance >2kOhm
No-load supply current mA <= 8
Short circuit protection yes
Protected against polarity rev
yes
Balluff GmbH
Postfach 1160
73761 Neuhausen
Telefon (07158) 173-0
Telefax (07158) 5010
04.06.2004 / Online-Information