Balluff BFIDU05 User Manual

Model:
BF-IDU05 Data Sheet
RFID Reader
Page 1 of 3
Operational Description
Electrical Data
Operating voltage Vs
21.6 .. 26.4 V DC
Current draw (at 24 V DC)
400 mA
Operating Frequency
902 .. 928 MHz
Operating channels (in MHz)
902.75 903.25 903.75 904.25 904.75 905.25 905.75
906.25 906.75 907.25 907.75 908.25 908.75 909.25
909.75 910.25 910.75 911.25 911.75 912.25 912.75
913.25 913.75 914.25 914.75 915.25 915.75 916.25
916.75 917.25 917.75 918.25 918.75 919.25 919.75
920.25 920.75 921.25 921.75 922.25 922.75 923.25
923.75 924.25 924.75 925.25 925.75 926.25 926.75
927.25
Maximum Transmit Power
36 dBm (4 W) EIRP1
Maximum Port Power
30 dBm2
Mechanical Data
Housing material: Aluminium, anodized Weight: 850 g Ambient temperature range: -20°C ... +55°C Device size: Length x Width x Height = 188 mm x 105 mm x 57 mm
1
Maximum Transmit Power is ensured by the software UHF Manager by consideration of cable loss and antenna gain. The UHF Manager is used to adjust the RFID reader through the mentioned controller.
2
Maximum Port Power is also limited by the software UHF Manager.
Model:
BF-IDU05 Data Sheet
RFID Reader
Page 2 of 3
Regulatory Notes
USA:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance voids the user's authority to operate this equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/TV technician for help.
Radiofrequency radiation exposure Information: This equipment complies with FCC and IC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with minimum distance of 50 cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un Environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 50 cm de distance entre la source de rayonnement et votre corps.
Ce transmetteur ne doit pas être place au même endroit ou utilise simultanément avec un autre transmetteur ou antenne.