This manual uses the following conventions:
"User" refers to anyone using a C827 reader.
"Reader" refers to the C827 reader.
"You" refers to the System Administrator or Technical Support person using this manual to
install, configure, operate, maintain or troubleshoot a C827 reader.
REFERENCE DOCUMENTATION
For further details refer to the Cobalt Dashboard™ Reference Manual, C-Macro Builder™
Reference Manual, and the ABx Command Protocol Reference Manual.
SERVICE AND SUPPORT
Datalogic provides several services as well as technical support through its website. Log on
to www.automation.datalogic.com and click on the links
PRODUCTS
Search through the links to arrive at your product page which describes specific Info,
Features, Applications, Models, Accessories, and Downloads including the Cobalt
Dashboard™ utility program, which allows system testing, monitoring, and configuration
using a PC. It provides Serial RS232 interface configuration.
SERVICE
- Overview
- Sales Network
- Helpdesk
- Material Return Authorization
- Warranty Extensions and Maintenance Agreements
- Listing of Subsidiaries,Repair Centers,Partners
PATENTS
This product is covered by one or more of the following patents:
US 5,621,199; JP 3,728,699.
indicated for further information:
iv
COMPLIANCE
This product is intended to be installed by Qualified Personnel only.
This product must not be used in explosive environments.
RADIO COMPLIANCE
ENGLISH
Contact the competent authority responsible for the management of radio frequency devices
of your country to verify any possible restrictions or licenses required.
For further information, refer to the web site:
http://ec.europa.eu/enterprise/sectors/rtte/
ITALIANO
Prendi contatto con l'autorità competente per la gestione degli apparati a radio frequenza del
tuo paese, per verificare eventuali restrizioni o licenze.
Ulteriori informazioni sono disponibili sul sito:
http://ec.europa.eu/enterprise/sectors/rtte/
FRANÇAIS
Contactez l'autorité compétente en la gestion des appareils à radio fréquence de votre pays
pour vérifier d'éventuelles restrictions ou licences. Pour tout renseignement vous pouvez
vous adresser au site web:
http://ec.europa.eu/enterprise/sectors/rtte/
DEUTSCH
Wenden Sie sich an die für Radiofrequenzgeräte zuständige Behörde Ihres Landes, um zu
prüfen ob es Einschränkungen gibt, oder eine Lizenz erforderlich ist.
Weitere Informationen finden Sie auf der Web Seite:
http://ec.europa.eu/enterprise/sectors/rtte/
ESPAÑOL
Contacta la autoridad competente para la gestión de los dispositivos de radio frecuencia de
tu país, para verificar cualesquiera restricciones o licencias posibles requerida.
Además se puede encontrar mas información en el sitio:
Web: http://ec.europa.eu/enterprise/sectors/rtte/
POWER SUPPLY
This device is intended to be supplied by a UL Listed or CSA Certified Power Unit with
«Class 2» or LPS power source.
FCC COMPLIANCE
v
Modifications or changes to this equipment without the expressed written approval of
Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference which may cause undesired
operation.
FCC ID : E36-0003
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
vi
GETTING STARTED
1
1 GETTING STARTED
1.1 INTRODUCTION
Datalogic Automation's passive read/write system is a complete family of field-proven
read/write Radio Frequency Identification products. The system consists of reader/writers,
antennas and controllers or bus interfaces, RF tags, and ancillary equipment. Tags can be
attached to a product or its carrier and act as an electronic identifier, job sheet, portable
database, or manifest. Tags are read and updated via a Datalogic Automation Reader/Writer
through any nonconductive material while moving or standing still.
The passive design of the Read/Write system uses the RF field from the antenna to power
the tag, eliminating the need for tag batteries. The passive read/write system is designed to
provide cost effective RFID data collection and control solutions to less demanding
automation and material handling applications.
The C827 Series Reader/Writer uses a standard limit switch type enclosure to house the
controller board. The C827 has an integrated antenna with vertical and horizontal read
orientations. The C827-03 features an 18 mm tubular remote antenna at the end of a 1 meter
cable. The C827-06 has a rectangular, 30 x 40 mm remote antenna at the end of a 1 meter
cable. The system uses the internationally recognized ISM frequency of 13.56 MHz to both
power the tag, and to establish a radio link to transfer the information.
The C827 Reader/ Writer is a stand alone unit that communicates to the host over an RS232
point-to-point interface. The C827 standard application program supports the well
established ABx protocol and includes all the command functions for efficient serial and RFID
communications.
1.2 UNPACKING AND INSPECTION
Unpack the Reader/Writer and save the original shipping carton and packing material in case
any item has to be returned to Datalogic Automation. Inspect each item carefully for evidence
of damage. If any item appears to be damaged, notify your Datalogic Automation
representative immediately.
Check that all of the following items are present:
This manual presents in Chapters 2, 3, and 4 the essential information required for installing,
connecting and powering the C827 Series. The following chapters explain the configuration
and operation of the C827 Series Reader/Writer.
1
2
C827 REFERENCE MANUAL
2 MECHANICAL SPECIFICATIONS
2.1 DIMENSIONS
Figure 2-1 shows the dimensions and mounting hole locations for the C827 Reader/Writer.
2
Figure 2-1. C827 dimensions and mounting hole locations
Loading...