Ballu BSZ-30H Service Manual

WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS
SERVICE MANUAL
BSZ-30H
No.TE100115
CONTENTS
1. IMPORTANT NOTICE ···································2
2. TECHNICAL SPECIFICATION ·····················3
3. OPERATION DETAILS ·······························4
4. WIRING DIAGRAM ············· 12
5. EXPLOSION VIEW ····························13
6. PARTS LIST ·············15
IMPORTANT NOTICE
This service manual is intended for use by individuals possessing adequate backgrounds of electrical, electronic and mechanical experience. Any attempt to repair the appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
The information, specifications and parameter are subject to change due to technical modification or improvement without any prior notice. The accurate specifications are presented on the nameplate label.
How to order spare parts
To have your order filled promptly and correctly, please furnish the following information:
1. Model No. with Indoor or Outdoor
2. No. in the Explosion View
3. Part Name
4. The quantity you ordered
TCL Air Conditioner Service ManualTCL Air Conditioner Service ManualTCL Air Conditioner Service Manual
Air Conditioner Service Manual
2
Air Conditioner Service Manual
3
Technical Specifications
Model No. BSZ-30H
Type Heat Pump Control type Remote Rated cooling capacity Btu/h 30000 Rated heating capacity Btu/h 32000 EER for cooling Btu/h.w 8.6 COP for heating W/W 2.84 Moisture removal Liters/h 2.5
High dB(A) 52 Med. dB(A) 48
Indoor noise level at cooling
Low dB(A) 45
Outdoor noise level dB(A) 62
Electrical Data
Power supply 220V~/50Hz
Voltage Range V
Cooling A 16.0
Rated current
Heating A 15.0
Cooling W 3500
Rated input
Heating W 3300
Refrigerating System
Refrigerant/Charge Gram R22/2050g
Type Rotary Model
----
LRA A ----
Compressor
MFG ----
Evaporator Louver fin and grooved tube type (ϕ7) Condenser Corrugated fin and grooved tube type (ϕ9.52) Expansion device Capillary tube Defrosting system Microcomputor controlled reverse system
Fan System
Indoor air circulation/Hi Cooling m3/h 1200/1200 Indoor fan type Cross flow
Cooling rpm 1300/1150/1000 Heating rpm 1300/1150/1001 Dry rpm 1000
Indoor fan speed H/M/L
Sleep rpm 1000 Indoor fan motor output W 50 Outdoor air circulation m3/h Outdoor fan type Propeller fan Outdoor fan speed rpm 850 Outdoor fan motor output W 100
Connections
Refrigerant coupling Flare type
Gas Inches 3/8 Connecting Pipe
Liquid Inches 5/8 Connecting Wiring Size x Core number Drainage Pipe O.D 16mm
Others
Suitable area m2 50~70
Indoor mm 1240x325x250 Net dimensions (W x H x D)
Outdoor mm 902x650x307
Indoor kg 18 Net weight
Outdoor kg 60
Indoor mm 1317×422×338 Packing dimensions (W x H x D)
Outdoor mm 1027x705x433
Indoor kg 23 Gross weight
Outdoor kg 66 Loading Capacity 40’/40’HC 111/135
4
Note: Each mode and relevant function will be further specified in following pages.
SLEEP
FAN
TIMER
SWING
ON/OFF
MODE
MID
SWING
AUTO
DRY FAN HEAT
COOL
FEEL
SLEEP
TIMER ON
HIGH
LOW
TMIER OFF
The remote controller transmits signals to the system.
Remote controller
1
2
4
3
5
6
7
8
8
4
MODE button
FAN SPEED control button
UP button (TOO COOL button)
DOWN button (TOO WARM button)
ON/OFF button
SLEEP button
VANE control button
TIMER button
Used to select the type of operation mode: Feel, Cooling, Dry, Fan and Heating(Only for Heat Pump).
Used to select the indoor fan motor speed: Auto, High, Mid and Low.
Used to increase the set room temperature
and time.
Used to decrease the set room temperature and time.
Used to set or cancel sleep mode operation.
Used to start and stop operation when pressed.
Used to adjust airflow direction.
Used to select TIMER operation.
Remote controller
6
2
5
3
7
1
11
Air Conditioner Service Manual
Operation Details
Remote Control
The remote controller is not presetted as Cooling Only Air Conditioner or Heat Pump by manufacturer. Each time after the remote controller replace batteries or is energized, the arrowhead will flashes on the front of
Heat or Cool on LCD of the remote controller. User can preset the remote controller type depending on the air conditioner type you have purchased as follows: Press any button when the arrowhead flashes on the front of Cool , Cooling Only is set. Press any button when the arrowhead flashes on the front of Heat , Heat Pump is set. If you don t press any button within 10 seconds, the remote controller is preset as Heat Pump automatically.
Note :
If the air conditioner you purchased is a Cooling Only one, but you preset the remote controller as Heat Pump, it doesn t bring any matter. But if the air conditioner you purchased is a Heat Pump one, and you preset the remote controller as Cooling Only, then you CAN NOT preset the Heating operation with the remote controller.
Air Conditioner Service Manual
5
Electronic controller:
1.Automatic mode
1) Initial RT determines the working mode and ST,the mode is determined effective only once unless
A/C shut-down then re-started. If from other modes switches to autoamatic mode (including mode
conversion after shutdown), it should be that the compress stop more than 3 min then temperature
judgement and automatic mode are conducted (it can conduct immediately from fan mode switched
to automatic, the indoor fan stops, three minutes later the response is made and start up). Within 3
min, the output as: Showing the room temperature, indoor fans starts (or anti-cold airflow), the
outdoor fan stops;
2) With memory controller, once being turned off or in case of an accidently power cut, the A/C is able
to retain and restore the original mode when being turned on or the power supply is resumed, if the
auto restart function activated. power-down after power-on; while if the auto restart fundction isn’t
activated, the A/C enters standby state.
Heat pump
Mode Initial RT Initial ST
Cooling
RT26 23
Dehumifying
26℃>RT20 18
Heating
RT20 23
Cooling-only
Mode Initial RT Initial ST
Cooling
RT26 23
Dehumifying
26℃>RT20 18
Ventilating
RT20
Under automatic mode (including from automatic converted into dehumidifying Dry mode), when the
temperature up and down signals from the remote controller is received, the setting temperature ST adjusts correspondingly to the current room temperature plus or minus 1, the automatic regulating temperature range is ± 2℃.
2Cooling mode
1) The control of the compressor a. When RT-ST≥1℃,the compressor is running. b. When RT-ST<-1℃,the compressor is off. c. When -1℃≤RT-ST<1℃, the compressor keeps its original state.
2) Outdoor fan motor and the compressor run simultaneously (except for defrosting).
3) The control of indoor fan motor:
a. Indoor fan motor can operate by automatic, low, middle, and high airflow speed circularly. b. Indoor fan motor’s the automatic airflow speed control Indoor fan motor can operate by automatic
as shown in Figure 1:
Hi
Mid
Lo
RT-ST 1℃ 2℃ 4
Figure 1 Cooling automatic airflow
When the temperature changes lead to changes in airflow speed, the switch can only be made
orderly, and every grade of air flow speed runs 1 minute at least.