Product Information Packet
VEM3212T
5HP,3450RPM,3PH,60HZ,182TC,3544M,OPEN,F1
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
Product Information Packet: VEM3212T - 5HP,3450RPM,3PH,60HZ,182TC,3544M,OPEN,F1
Part Detail
Revision: M Status: PRD/A Change #: Proprietary: No
Type: AC Elec. Spec: 35WGL285 CD Diagram: CD0005 Mfg Plant:
Mech. Spec: 35Z323 Layout: 35LYZ323 Poles: 02 Created Date: 04-28-2015
Base: N Eff. Date: 12-05-2018 Leads: 9#16
Specs
Catalog Number: VEM3212T
Enclosure: OPEN
Frame: 182TC
Frame Material: Steel
Output @ Frequency: 5.000 HP @ 60 HZ
Synchronous Speed @ Frequency: 3600 RPM @ 60 HZ
Voltage @ Frequency: 460.0 V @ 60 HZ
230.0 V @ 60 HZ
XP Class and Group: None
XP Division: Not Applicable
Agency Approvals: UR
CSA EEV
CSA
Auxillary Box: No Auxillary Box
Auxillary Box Lead Termination: None
Base Indicator: No Mounting
Bearing Grease Type: Polyrex EM (-20F +300F)
Insulation Class: F
Inverter Code: Not Inverter
KVA Code: M
Lifting Lugs: No Lifting Lugs
Locked Bearing Indicator: Locked Bearing
Motor Lead Quantity/Wire Size: 9 @ 16 AWG
Motor Lead Exit: Ko Box
Motor Lead Termination: Flying Leads
Motor Type: 3544M
Mounting Arrangement: F1
Power Factor: 89
Product Family: General Purpose
Pulley End Bearing Type: Ball
Pulley Face Code: C-Face
Pulley Shaft Indicator: Standard
Rodent Screen: None
RoHS Status: ROHS COMPLIANT
Blower: None
Shaft Extension Location: Pulley End
Page 2 of 10
Product Information Packet: VEM3212T - 5HP,3450RPM,3PH,60HZ,182TC,3544M,OPEN,F1
Current @ Voltage: 12.000 A @ 230.0 V
13.000 A @ 208.0 V
6.000 A @ 460.0 V
Design Code: A
Drip Cover: Drip Cover
Duty Rating: CONT
Electrically Isolated Bearing: Not Electrically Isolated
Feedback Device: NO FEEDBACK
Front Face Code: Standard
Front Shaft Indicator: None
Heater Indicator: No Heater
Shaft Ground Indicator: No Shaft Grounding
Shaft Rotation: Reversible
Shaft Slinger Indicator: No Slinger
Speed Code: Single Speed
Motor Standards: NEMA
Starting Method: Direct on line
Thermal Device - Bearing: None
Thermal Device - Winding: None
Vibration Sensor Indicator: No Vibration Sensor
Winding Thermal 1: None
Winding Thermal 2: None
Page 3 of 10