Product Information Packet
VEM3157T
2HP,1750RPM,3PH,60HZ,145TC,3526M,ODP,F1
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.

Product Information Packet: VEM3157T - 2HP,1750RPM,3PH,60HZ,145TC,3526M,ODP,F1
Part Detail
Revision: L Status: PRD/A Change #: Proprietary: No
Type: AC Elec. Spec: 35WGM496 CD Diagram: CD0005 Mfg Plant:
Mech. Spec: 35Z413 Layout: 35LYZ413 Poles: 04 Created Date: 04-24-2015
Base: N Eff. Date: 01-30-2018 Leads: 9#18
Specs
Catalog Number: VEM3157T
Enclosure: ODP
Frame: 145TC
Frame Material: Steel
Output @ Frequency: 2.000 HP @ 60 HZ
Synchronous Speed @ Frequency: 1800 RPM @ 60 HZ
Voltage @ Frequency: 460.0 V @ 60 HZ
230.0 V @ 60 HZ
XP Class and Group: None
XP Division: Not Applicable
Agency Approvals: UR
CSA EEV
CSA
Auxillary Box: No Auxillary Box
Auxillary Box Lead Termination: None
Base Indicator: No Mounting
Bearing Grease Type: Polyrex EM (-20F +300F)
Heater Indicator: No Heater
Insulation Class: F
Inverter Code: Inverter Ready
KVA Code: K
Lifting Lugs: No Lifting Lugs
Locked Bearing Indicator: Locked Bearing
Motor Lead Quantity/Wire Size: 9 @ 18 AWG
Motor Lead Exit: Ko Box
Motor Lead Termination: Flying Leads
Motor Type: 3526M
Mounting Arrangement: F1
Power Factor: 76
Product Family: General Purpose
Pulley End Bearing Type: Ball
Pulley Face Code: C-Face
Pulley Shaft Indicator: Standard
Rodent Screen: None
Blower: None
Shaft Extension Location: Pulley End
Page 2 of 10

Product Information Packet: VEM3157T - 2HP,1750RPM,3PH,60HZ,145TC,3526M,ODP,F1
Current @ Voltage: 2.900 A @ 460.0 V
5.800 A @ 208.0 V
5.800 A @ 230.0 V
Design Code: B
Drip Cover: No Drip Cover
Duty Rating: CONT
Electrically Isolated Bearing: Not Electrically Isolated
Feedback Device: NO FEEDBACK
Front Face Code: Standard
Front Shaft Indicator: None
Shaft Ground Indicator: No Shaft Grounding
Shaft Rotation: Reversible
Shaft Slinger Indicator: No Slinger
Speed Code: Single Speed
Motor Standards: NEMA
Starting Method: Direct on line
Thermal Device - Bearing: None
Thermal Device - Winding: None
Vibration Sensor Indicator: No Vibration Sensor
Winding Thermal 1: None
Winding Thermal 2: None
Page 3 of 10