![](/html/2c/2c27/2c27b749d4ca21e72c48eaa4984667f33f4d0f0c16e9f61dce4ebe405a862ab5/bg1.png)
Product Information Packet
RHM3112A
.75HP,1725RPM,3PH,60HZ,56H,3420M,OPEN,F1
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
![](/html/2c/2c27/2c27b749d4ca21e72c48eaa4984667f33f4d0f0c16e9f61dce4ebe405a862ab5/bg2.png)
Product Information Packet: RHM3112A - .75HP,1725RPM,3PH,60HZ,56H,3420M,OPEN,F1
Part Detail
Revision: M Status: INA/A Change #: Proprietary: No
Type: AC Elec. Spec: 34WG2100 CD Diagram: CD0007 Mfg Plant:
Mech. Spec: 34H323 Layout: 34LYH323 Poles: 04 Created Date:
Base: RS Eff. Date: 04-16-2012 Leads: 12#18
Specs
Catalog Number: RHM3112A
Frame: 56H
Output @ Frequency: .750 HP @ 60 HZ
Synchronous Speed @ Frequency: 1800 RPM @ 60 HZ
Voltage @ Frequency: 230.0 V @ 60 HZ
460.0 V @ 60 HZ
XP Division: Not Applicable
Agency Approvals: CSA
UR
Auxillary Box: No Auxillary Box
Auxillary Box Lead Termination: None
Base Indicator: Resilient
Bearing Grease Type: Polyrex EM (-20F +300F)
Blower: None
Current @ Voltage: 1.500 A @ 460.0 V
3.000 A @ 230.0 V
3.600 A @ 208.0 V
Inverter Code: Not Inverter
KVA Code: K
Lifting Lugs: No Lifting Lugs
Locked Bearing Indicator: No Locked Bearing
Motor Lead Quantity/Wire Size: 12 @ 18 AWG
Motor Lead Exit: Terminal Panel Or Lead Hole
Motor Lead Termination: Flying Leads
Motor Type: 3420M
Mounting Arrangement: F1
Power Factor: 60
Product Family: General Purpose
Pulley End Bearing Type: Ball
Pulley Face Code: Resilient Mount
Pulley Shaft Indicator: Standard
Rodent Screen: None
Shaft Extension Location: Pulley End
Shaft Ground Indicator: No Shaft Grounding
Design Code: B
Shaft Rotation: Reversible
Page 2 of 10
![](/html/2c/2c27/2c27b749d4ca21e72c48eaa4984667f33f4d0f0c16e9f61dce4ebe405a862ab5/bg3.png)
Product Information Packet: RHM3112A - .75HP,1725RPM,3PH,60HZ,56H,3420M,OPEN,F1
Drip Cover: No Drip Cover
Duty Rating: CONT
Electrically Isolated Bearing: Not Electrically Isolated
Feedback Device: NO FEEDBACK
Front Face Code: Resilient Mount
Front Shaft Indicator: None
Heater Indicator: No Heater
Insulation Class: B
Shaft Slinger Indicator: No Slinger
Speed Code: Single Speed
Motor Standards: NEMA
Starting Method: Direct on line
Thermal Device - Bearing: None
Thermal Device - Winding: None
Vibration Sensor Indicator: No Vibration Sensor
Winding Thermal 1: Automatic Thermal Overload
Winding Thermal 1 Location: SB
Page 3 of 10