Baldor MN806 User Manual

SOLID STATE
STARTER PARTS
BREAKDOWN BY PRODUCT LINE
MN806 Printshop 2000 7/96

Table of Contents

Control Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Section
Dynamic Brakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B
General Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G
Multipurpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G
Ramp Up/RampDown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .G
Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S
Torque Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S
This should be used as a guide to help identify parts primarily for older controls. Current products have a parts list in the manuals. The parts have been cataloged in MN805. This will allow a user to locally find parts like fuses, transformers, and circuit breakers we no longer stock.
Note: Older controls are often modified and may not have the original factory supplied parts.

Dynamic Brakes

There are 2 styles of brakes built by Baldor. Verify the type of brake first.
Manual: see PR802 Binder.
Brake
Voltage
7 - 208/230/460 VAC
AMP Size
0 - 8 AMPS 1 - 16 AMPS 2 - 30 AMPS 3 - 55 AMPS 4 - 135 AMPS
C - Control only
Enclosure Type
A - Open B - NEMA 1 C - NEMA 12 D - NEMA 4 P - PANEL
Old Style
B 7 1 C P
Custom Product
The “old style” brake has most parts still available. The major exception is the braking module ( A ) which is no longer available.
Manual: MN802.
New Style
Brake
UL Style
Voltage
AMP Rating
Control Only
Enclosure
B Q 7 1 6
0
C P
The New style brake parts list is covered in the brake manual. Please see the manual for detail parts information.
B-1
Old Style (Non UL) Spare Parts Size 0, 1 and 2
B
D
A Braking Module
This module is not available. If the module can not be repaired the brake must be replaced. Sizes 0, 1 and 2 have the SCRs in the module and can be replaced.
C Fuses
C
A
E
Mounted inside
Size 3, 4 and 5
B
E
B Control Transformer
Over a 15 year period many brands of transformers have been used., Control transformers are locally available. Baldor may stock a simular transformer. To check, get the VA, Voltage, of the existing transformer. See MN805.
C
A
D
Power Fuses Control Transformer
Size Baldor Buss Gould Baldor Buss Gould
0,1 FU50020 FWP0020 A70P30 FUS0005 FNM1/2 TRM 1/2
2 FU50030 FWP60 A70P60 FUS0005 FNM1/2 TRM 1/2 3 FU50045 FWP150 A70P150 FUS0005 FNM1/2 TRM 1/2 4 FUS0050 FWP350 A70P350 FUS0010 FNM1 TRM 1
Baldor still uses the control transformer fuses. All of these fuses should be locally available. There are 2 types of fuses. The large power fuses are in the fuse holder mounted on the panel. There are two
brands available, Buss and Gould. The second type of fuse is a single fuse for the control power transformer.
D Braking Contactor
Over a 15 year period several brands of contactors have been used. They are available locally. Baldor may stock a simular contactor. To check, get the part number of the existing device.
E Replacement SCRs/Diode and power cells
Sizes 0-3: The SCR and Diode are in the same package. Size 0, 1 and 2 are mounted in the module. The SCR/Diode in the size 4 are separate.
SCR/Diode Power Cell
Size 460 VAC 575 VAC 460 VAC 575 VAC
0/1/2 SCR0075 SCR0080
3 SCR085 SCR0087 BPC3A BPC3B
4
SCR0120 SCR0123
SCR055 SCR0060
BPC4A BPC4B
1 If the SCR/Diode are replaced an SCR kit is also required.
B-2

DEFINITE PURPOSE

Manual: MN830.
Part Numbering
TYPE OF CONTROL
D - Definite Purpose Control
VOLTAGE CODE
7 - 208/230/460 VAC 60 hz. 8 - 208/230/460/575 VAC 60 hz. 9 - 380/415 VAC 50 hz.
D
7
0
C
A
ENCLOSURE
A - Open B - NEMA 1 C - NEMA 12/3R P - Panel Mount
CONFIGURATION
C - Control only
AMP RATING
0 - 8 amp 1 - 16 amp 2 - 30 amp 3 - 50 amp 4 - 70 amp 5 - 135 amp
A Module (LCM)
*TYPE SIZE AMP 60Hz 50Hz
I 0,1,2 8,16,30
II 3,4 50,70 D8X D9X
III, IV 3,4,5 50,70,
B SCR/Power Cell(s)
SIZE AMP SCR/DIODE POWER CELL
SIZE 208-460VAC 575VAC
0,1 8,16 SCR0035 SCR0040
2 30 SCR0045 SCR0050 — 3 50 SCR0085 SCR0087 DO55B DO55B 4 70 SCR0150 SCR0150 D080B D080B
5 135 SCR0120 SCR0123 D160A D160B
SCR0055 SCR0060
Top number is diode.
• Requires a part (SCRKIT) for proper installation.
• Complete power cell D160A.
Power cell contains SCR/Diode and heatsink for one phase. The 50 and 70 power cell contains all 3 phases.
135
REPLACE ENTIRE
UNIT
L8X L9X
D MOV-All Sizes
INPUT VOLTAGE PAR T
208-460 VAC MOV505EL
575 VAC MOV620EL
E Thermostat
*TYPE SIZE AMP PART
III, IV 3,4,5 50,70,135 TSW0010
F Line Load Terminals
*TYPE SIZE AMP PART NUMBER
I––
II 3,4 50,70 TBK0155 III 3,4 50,70 TBK0155 IV 5 135 TBK0065
C Fans
* See page D2.
*TYPE SIZE AMP PART NUMBER
III 3,4 50,70 FAN0005 IV 5 135 FAN0005
G Control Terminals
*TYPE SIZE AMP PART NUMBER
III 3,4 50,70 TBK0180 BLK
IV 5 135 TBK0185 END PIECE
D-1
Definite Purpose Controls
Reference
8 AND 16 AMP
I
OPEN
II
F
A
G
B
F
30 AMP
8-70 AMP
NEMA 12/3R
III
G
F
E
B
F
E
A
C
IV
FF
G
A
EEE
C
50 AND 70 AMP
PANEL AND NEMA 1
PANEL AND NEMA 1
D-2
135 AMP
General Purpose/Ramp Up - Ramp Down
and non UL Versions of Multipurpose Control
The General Purpose (G controls) and the Ramp Up / Ramp Down (R controls) are no longer available. However, some parts are still available.
The first Multipurpose Softstarter used the same parts as the G and R controls except for the module. The current Multipurpose product line has a complete spare parts list in the manual.
Manual: see PR802 Binder.
Type of Control
G - General Purpose M - Multipurpose (Non UL) R - Ramp up / Ramp down
Voltage Code
1 - 208 60Hz 2 - 230 60Hz 3 - 380 50Hz 4 - 400 50Hz 5 - 460 60Hz 6 - 575 60Hz 7 - 208/230/460 60Hz 8 - 230/460/575 60Hz 9 - 220/380 50Hz
AMP Size
G and R M AMP Rating
0A 8 1B 16 2C 30 3D 55 –E 80 4 F 135 5 G 250 6 H 400 7 J 700
G 7 6 A B
Custom Panel
Enclosure
A - Open B - NEMA 1 C - NEMA 12 D - NEMA 4 E - NEMA 3R P - Panel Only
Configuration
A - Combination B - Non Combination C - Control Only G - Bypass Combination H - Bypass Non Combination J - Bypass Control Only
In the Soft Starter Binders (PR802) there are layout drawings, wiring diagrams and manuals.
G-1
CT1
CT1
CT2
General Purpose/Ramp Up - Ramp Down
and non UL Versions of Multipurpose Control
Size 2
Size 0, 1
A
Size 3 Size 4, 5, 6, 7
F
G
A
G
F
D
K
D
E
G
A
C
F
F
D D
J
H
B
J
G
C
B
H
J
A
K
G G
G-2
E E
E
A Control Module
The Control Module is no longer available. The Multipurpose module can be used as a replacement. For sizes 0, 1, 2 (G and R controls), a replacement control is required. For sizes 4-7 and D-J a replacement module can be used. For 60Hz applications use the MB8X, and for 50Hz applications use the MB9X. A conversion manual is included with each Multipurpose module.
B Circuit Breakers
The Circuit breakers used were Westinghouse and later on Square D. Baldor no longer stocks these breakers and we no longer have an OEM buying agreement from these manufactures. Westinghouse and Square D breakers should be locally available.
C Overload Relays
There were several brands of overload relays used in the G, R and M controls. If a new heater is required for the starter contact your team with the control size, the motor AMPS and the brand of overload that is installed.
D Relays
The plug in relays in the controls are very standard and are available locally. Baldor does stock most of the relays. It is common for relays to be added to controls by the end users.
To determine if the relays are available from Baldor. The following information is required.:
• What is the coil voltage of the relay?
• What is the number of pins or blades in the bottom of the relay?
• Are there pins or blades coming from the bottom of the relay?
• Is there a part number on the relay?
See catalog MN805.
E Fans
SIZES
G AND R M
3, 4 D, E, F Fan 0005
5, 6, 7 G, H, I Fan 0010
PART NUMBER
F Current Calibrators
The G and R modules require a current calibrator. The current calibrator is nothing more than a resistor that sets the current during starting. If the user needs to change this resistor (current calibrator). Contact your team with the motor current and the control size.
G-3
6 Power Cells and SCRs
CONTROL TYPE POWER CELL REPLACEMENT SCR AMP NON UL MAX SIZE G and R M VAC CAT. NO. CAT. NO.
8, 16 0, 1 A, B 460 SCR0005
575 SCR0010 466 SCR0015
30 20 C
575 SCR0020 460 PC1B SCR0025(3)
55 3 D
575 PC1B SCR0025(3) 460 PC2B SCR0130(3)
80 E
575 PC2B SCR130(3) 460 PC4A SCR0055(2)
135 4
F
575 PC4B SCR0060(2) 460 PC4A SCR0065(2)
250 5
G
575 PC4B SCR0070(2) 460 PC7B SCR0095(2)
400 6
H
575 PC7B SCR0095(2) 460 PC7B SCR0095(2)
700 7
J
575 PC7B SCR0095(2)
H MOVs
There are only two types of MOVs depending upon the voltage rating of the control.
208 - 460VAC 50 - 60Hz - MOV505EL 575VAC 60Hz - MOV620EL
J CT (Current Transformers)
There are two CT’s on some controls; a small one – CT1, and a larger doughnut type – CT2.
CT1 - CT6K1 (used on G and R sizes 3-7, M sizes D - J).
CT 2
G and R M CT2
4, 5, 6 F, G, H CTX0025
7 J CTX 0020
G-4
K Control Transformers
Control Transformers are locally available. Baldor stocks simular transformers byt may require panel modification to fit.
L Bypass Contactors
The bypass used for G and R controls have varied during the years. Currently Baldor is using ASEA or ABB contactors which were used for several years of production of the G, R and M controls. The ASEA/ABB contactors are normally stocked by Baldor. If the contactor is not a ASEA/ABB Baldor does not stock replacements. A replacement should be found locally.
Cross Over Chart
To convert an Old Style General Purpose, Ramp Up/Down, or Non UL Style Multipurpose, use the chart below. The last digits remain the same. The Multipurpose Soft Starter will be in a larger enclosure than the old control.
SIZE
PURPOSE UP/DOWN MULTIPURPOSE MULTIPURPOSE
0 G70** R70** MA7A** MA7-008-** 1 G71** R71** MA7B** MA7-016-** 2 G72** R72** MA7C** MA7-030-** 3 G73** R73** MA7D** MB7-055-**
4 G74** R74** MB7F** MB7-160-** 5 G75** R75** MB7G** MB7-250-** 6 G76** R76** MB7H** MB7-420-** 7 G77** R77** MB7J** MB7-840-**
** These digits remain the same.
GENERAL RAMP NON UL UL
Example #1:
General Purpose Starter G76AB is now MB7-420-AB.
MB7E** MB7-080-**
Example #2:
Non UL Multipurpose Starter MA7BAP is now MA7-016-AP.
G-5
K Control Transformers
Control Transformers are locally available. Baldor stocks simular transformers byt may require panel modification to fit.
L Bypass Contactors
The bypass used for G and R controls have varied during the years. Currently Baldor is using ASEA or ABB contactors which were used for several years of production of the G, R and M controls. The ASEA/ABB contactors are normally stocked by Baldor. If the contactor is not a ASEA/ABB Baldor does not stock replacements. A replacement should be found locally.
Cross Over Chart
To convert an Old Style General Purpose, Ramp Up/Down, or Non UL Style Multipurpose, use the chart below. The last digits remain the same. The Multipurpose Soft Starter will be in a larger enclosure than the old control.
SIZE
PURPOSE UP/DOWN MULTIPURPOSE MULTIPURPOSE
0 G70** R70** MA7A** MA7-008-** 1 G71** R71** MA7B** MA7-016-** 2 G72** R72** MA7C** MA7-030-** 3 G73** R73** MA7D** MB7-055-**
4 G74** R74** MB7F** MB7-160-** 5 G75** R75** MB7G** MB7-250-** 6 G76** R76** MB7H** MB7-420-** 7 G77** R77** MB7J** MB7-840-**
** These digits remain the same.
GENERAL RAMP NON UL UL
Example #1:
General Purpose Starter G76AB is now MB7-420-AB.
MB7E** MB7-080-**
Example #2:
Non UL Multipurpose Starter MA7BAP is now MA7-016-AP.
G-5