Product Information Packet
M7090T-I
75/100HP,1475/1780RPM,3PH,50/60HZ,405T
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.

Product Information Packet: M7090T-I - 75/100HP,1475/1780RPM,3PH,50/60HZ,405T
Part Detail
Revision: J Status: INA/A Change #: Proprietary: No
Type: AC Elec. Spec: 16WGW729 CD Diagram: CD0180 Mfg Plant:
Mech. Spec: 16M014 Layout: 16LYM014 Poles: 04 Created Date:
Base: RG Eff. Date: 02-28-2011 Leads: 9#4
Specs
Catalog Number: M7090T-I
Enclosure: TEFC
Frame: 405T
Frame Material: Iron
Output @ Frequency: 100.000 HP @ 60 HZ
75.000 HP @ 50 HZ
Synchronous Speed @ Frequency: 1800 RPM @ 60 HZ
1500 RPM @ 50 HZ
Voltage @ Frequency: 230.0 V @ 60 HZ
190.0 V @ 50 HZ
460.0 V @ 60 HZ
380.0 V @ 50 HZ
XP Division: Not Applicable
Agency Approvals: UL
CSA
Auxillary Box: No Auxillary Box
Auxillary Box Lead Termination: None
Front Face Code: Standard
Front Shaft Indicator: None
Heater Indicator: No Heater
Insulation Class: F
Inverter Code: Not Inverter
KVA Code: G
Lifting Lugs: Standard Lifting Lugs
Locked Bearing Indicator: Locked Bearing
Motor Lead Quantity/Wire Size: 9 @ 4 AWG
Motor Lead Exit: Ko Box
Motor Lead Termination: Flying Leads
Motor Type: 1676M
Mounting Arrangement: F1
Power Factor: 91
Product Family: General Purpose
Pulley End Bearing Type: Ball
Pulley Face Code: Standard
Base Indicator: Rigid
Pulley Shaft Indicator: Standard
Page 2 of 7

Product Information Packet: M7090T-I - 75/100HP,1475/1780RPM,3PH,50/60HZ,405T
Bearing Grease Type: Polyrex EM (-20F +300F)
Blower: None
Current @ Voltage: 218.000 A @ 230.0 V
200.000 A @ 190.0 V
109.000 A @ 460.0 V
100.000 A @ 380.0 V
Design Code: B
Drip Cover: No Drip Cover
Duty Rating: CONT
Electrically Isolated Bearing: Not Electrically Isolated
Feedback Device: NO FEEDBACK
Rodent Screen: None
Shaft Extension Location: Pulley End
Shaft Ground Indicator: No Shaft Grounding
Shaft Rotation: Reversible
Shaft Slinger Indicator: No Slinger
Speed Code: Single Speed
Motor Standards: NEMA
Starting Method: Direct on line
Thermal Device - Bearing: None
Thermal Device - Winding: Normally Closed Thermostat
Vibration Sensor Indicator: No Vibration Sensor
XP Temp Code: T3C
Page 3 of 7

Product Information Packet: M7090T-I - 75/100HP,1475/1780RPM,3PH,50/60HZ,405T
AC Induction Motor Performance Data
Record # 20775 - Typical performance - not guaranteed values
Winding: 16WGW729-R003 Type: 1676M Enclosure: XPFC
Nameplate Data
460 V, 60 Hz:
High Voltage Connection
Rated Output (HP) 100//75 Full Load Torque 295 LB-FT
Volts 230/460//190/380 Start Configuration direct on line
Full Load Amps 218/109//200/100 Breakdown Torque 965 LB-FT
R.P.M. 1775//1475 Pull-up Torque 292 LB-FT
Hz 60//50 Phase 3 Locked-rotor Torque 366 LB-FT
NEMA Design Code B KVA Code G Starting Current 726 A
Service Factor (S.F.) 1.15 No-load Current 30.2 A
NEMA Nom. Eff. 94.5 Power Factor 91 LinelineRes.@25ºC 0.0547Ω
Rating - Duty 40C AMB-CONT Temp. Rise @ Rated Load 64°C
Locked-rotor Power Factor 26
Rotor inertia 25.9 LB-FT2
Load Characteristics 460 V, 60 Hz, 100 HP
% of Rated Load 25 50 75 100 125 150
Power Factor 66 84 89 91 91 91
Efficiency 91.2 94.3 94.8 94.6 94.2 93.9
Speed 1793 1788 1784 1779 1774 1768
Line amperes 39.4 59.2 83.2 109 136 163
Page 4 of 7

Product Information Packet: M7090T-I - 75/100HP,1475/1780RPM,3PH,50/60HZ,405T
Performance Graph at 460V, 60Hz, 100.0HP Typical performance - Not guaranteed values