380.0 V @ 50 HZ
XP Division:Not Applicable
Agency Approvals:CSA
UL
Auxillary Box:No Auxillary Box
Auxillary Box Lead Termination:None
Front Face Code:Standard
Front Shaft Indicator:None
Heater Indicator:No Heater
Insulation Class:F
Inverter Code:Not Inverter
KVA Code:H
Lifting Lugs:Standard Lifting Lugs
Locked Bearing Indicator:Locked Bearing
Motor Lead Quantity/Wire Size:9 @ 6 AWG
Motor Lead Exit:Ko Box
Motor Lead Termination:Flying Leads
Motor Type:1472M
Mounting Arrangement:F1
Power Factor:88
Product Family:General Purpose
Pulley End Bearing Type:Sealed Bearing
Pulley Face Code:Standard
Base Indicator:Rigid
Pulley Shaft Indicator:Standard
Page 2 of 9
Product Information Packet: M7068T-I - 60/75hp,1450/1780rpm,3ph,50/60hz,365t
Bearing Grease Type:Polyrex EM (-20F +300F)
Blower:None
Current @ Voltage:85.000 A @ 460.0 V
Rodent Screen:None
Shaft Extension Location:Pulley End
Shaft Ground Indicator:No Shaft Grounding
Shaft Rotation:Reversible
Shaft Slinger Indicator:No Slinger
Speed Code:Single Speed
Motor Standards:NEMA
Starting Method:Direct on line
Thermal Device - Bearing:None
Thermal Device - Winding:None
Vibration Sensor Indicator:No Vibration Sensor
XP Temp Code:T3C
Page 3 of 9
Product Information Packet: M7068T-I - 60/75hp,1450/1780rpm,3ph,50/60hz,365t
AC Induction Motor Performance Data
Record # 17358 - Typical performance - not guaranteed values
Winding: 14WGW982-R006Type: 1472MEnclosure: XPFC
Nameplate Data
380 V, 50 Hz:
High Voltage Connection
Rated Output (HP)75//60Full Load Torque214 LB-FT
Volts230/460//190/380Start Configurationdirect on line
Full Load Amps170/85//164/82Breakdown Torque575 LB-FT
R.P.M.1780//1450Pull-up Torque271 LB-FT
Hz60//50Phase3Locked-rotor Torque361 LB-FT
NEMA Design CodeAKVA CodeHStarting Current596 A
Service Factor (S.F.)1.15No-load Current26.8 A
NEMA Nom. Eff.94.1Power Factor88LinelineRes.@25ºC0.0628Ω
Rating - Duty40C AMB-CONTTemp. Rise @ Rated Load59°C
S.F. AmpsTemp. Rise @ S.F. Load72°C
Locked-rotor Power Factor28
Rotor inertia13.6 LB-FT2
Load Characteristics 380 V, 50 Hz, 60 HP
% of Rated Load255075100125150S.F.
Power Factor56778588898989
Efficiency90.794.594.894.894.293.194.4
Speed1495149114871481147614691478
Line amperes33.947.363.982.310212394.1
Page 4 of 9
Product Information Packet: M7068T-I - 60/75hp,1450/1780rpm,3ph,50/60hz,365t
Performance Graph at 380V, 50Hz, 60.0HP Typical performance - Not guaranteed values
Page 5 of 9
Product Information Packet: M7068T-I - 60/75hp,1450/1780rpm,3ph,50/60hz,365t
AC Induction Motor Performance Data
Record # 20763 - Typical performance - not guaranteed values
Winding: 14WGW982-R006Type: 1472MEnclosure: XPFC
Nameplate Data
460 V, 60 Hz:
High Voltage Connection
Rated Output (HP)75//60Full Load Torque222 LB-FT
Volts230/460//190/380Start Configurationdirect on line
Full Load Amps170/85//164/82Breakdown Torque593 LB-FT
R.P.M.1780//1450Pull-up Torque257 LB-FT
Hz60//50Phase3Locked-rotor Torque342 LB-FT
NEMA Design CodeAKVA CodeHStarting Current608 A
Service Factor (S.F.)1.15No-load Current27.5 A
NEMA Nom. Eff.94.1Power Factor88LinelineRes.@25ºC0.0683Ω
Rating - Duty40C AMB-CONTTemp. Rise @ Rated Load63°C
S.F. AmpsTemp. Rise @ S.F. Load75°C
Locked-rotor Power Factor26
Rotor inertia13.6 LB-FT2
Load Characteristics 460 V, 60 Hz, 75 HP
% of Rated Load255075100125150S.F.
Power Factor57788588898889
Efficiency89.793.694.594.694.393.894.4
Speed1795179117861780177517671777
Line amperes34.948.86684.910512797
Page 6 of 9
Product Information Packet: M7068T-I - 60/75hp,1450/1780rpm,3ph,50/60hz,365t
Performance Graph at 460V, 60Hz, 75.0HP Typical performance - Not guaranteed values
Page 7 of 9
Product Information Packet: M7068T-I - 60/75hp,1450/1780rpm,3ph,50/60hz,365t
Page 8 of 9
Product Information Packet: M7068T-I - 60/75hp,1450/1780rpm,3ph,50/60hz,365t
Page 9 of 9
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.