![](/html/5f/5ff4/5ff43daf64735856974d8a66fc7d17dd98dcb517459e9bfc15c31ee38be25a39/bg1.png)
Product Information Packet
JMM7072T
5HP,3465RPM,3PH,60HZ,184JM,3634M,XPFC,F1
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
![](/html/5f/5ff4/5ff43daf64735856974d8a66fc7d17dd98dcb517459e9bfc15c31ee38be25a39/bg2.png)
Product Information Packet: JMM7072T - 5HP,3465RPM,3PH,60HZ,184JM,3634M,XPFC,F1
Part Detail
Revision: K Status: INA/A Change #: Proprietary: No
Type: AC Elec. Spec: 36WGY769 CD Diagram: CD0005 Mfg Plant:
Mech. Spec: 36E309 Layout: 36LYE309 Poles: 02 Created Date: 12-15-2010
Base: RG Eff. Date: 03-08-2016 Leads: 9#16
Specs
Catalog Number: JMM7072T
Enclosure: XPFC
Frame: 184JM
Frame Material: Steel
Output @ Frequency: 5.000 HP @ 60 HZ
Synchronous Speed @ Frequency: 3600 RPM @ 60 HZ
Voltage @ Frequency: 230.0 V @ 60 HZ
460.0 V @ 60 HZ
XP Class and Group: CLI GP D
XP Division: Division I
Agency Approvals: UL
CSA
Auxillary Box: No Auxillary Box
Auxillary Box Lead Termination: None
Base Indicator: Rigid
Bearing Grease Type: Polyrex EM (-20F +300F)
Blower: None
Inverter Code: Not Inverter
KVA Code: K
Lifting Lugs: No Lifting Lugs
Locked Bearing Indicator: Locked Bearing
Motor Lead Quantity/Wire Size: 9 @ 16 AWG
Motor Lead Exit: Ko Box
Motor Lead Termination: Flying Leads
Motor Type: 3634M
Mounting Arrangement: F1
Power Factor: 93
Product Family: General Purpose
Pulley End Bearing Type: Ball
Pulley Face Code: C-Face
Pulley Shaft Indicator: Tapped & Key
Rodent Screen: None
Shaft Extension Location: Pulley End
Shaft Ground Indicator: No Shaft Grounding
Current @ Voltage: 11.200 A @ 230.0 V
Shaft Rotation: Reversible
Page 2 of 10
![](/html/5f/5ff4/5ff43daf64735856974d8a66fc7d17dd98dcb517459e9bfc15c31ee38be25a39/bg3.png)
Product Information Packet: JMM7072T - 5HP,3465RPM,3PH,60HZ,184JM,3634M,XPFC,F1
5.600 A @ 460.0 V
Design Code: A
Drip Cover: No Drip Cover
Duty Rating: CONT
Electrically Isolated Bearing: Not Electrically Isolated
Feedback Device: NO FEEDBACK
Front Face Code: Standard
Front Shaft Indicator: None
Heater Indicator: No Heater
Insulation Class: B
Shaft Slinger Indicator: No Slinger
Speed Code: Single Speed
Motor Standards: NEMA
Starting Method: Direct on line
Thermal Device - Bearing: None
Thermal Device - Winding: Normally Closed Thermostat
Vibration Sensor Indicator: No Vibration Sensor
Winding Thermal 1: None
Winding Thermal 2: None
XP Temp Code: T2C
Page 3 of 10