![](/html/fa/facd/facd6a4ab71a2dee64de1f49825bffbacaefdf649f7c5af65268b1f11a3791cd/bg1.png)
Product Information Packet
JMM3155T
2HP,3450RPM,3PH,60HZ,145JM,3522M,OPSB,F1
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
![](/html/fa/facd/facd6a4ab71a2dee64de1f49825bffbacaefdf649f7c5af65268b1f11a3791cd/bg2.png)
Product Information Packet: JMM3155T - 2HP,3450RPM,3PH,60HZ,145JM,3522M,OPSB,F1
Part Detail
Revision: F Status: INA/A Change #: Proprietary: No
Type: AC Elec. Spec: 35WGT478 CD Diagram: CD0005 Mfg Plant:
Mech. Spec: 35NN833 Layout: 35LYNN833 Poles: 02 Created Date: 05-25-2010
Base: RG Eff. Date: 03-08-2016 Leads: 9#18
Specs
Catalog Number: JMM3155T
Enclosure: ODP
Frame: 145JM
Frame Material: Steel
Output @ Frequency: 2.000 HP @ 60 HZ
Synchronous Speed @ Frequency: 3600 RPM @ 60 HZ
Voltage @ Frequency: 208.0 V @ 60 HZ
230.0 V @ 60 HZ
460.0 V @ 60 HZ
XP Class and Group: None
XP Division: Not Applicable
Agency Approvals: UR
CSA
Auxillary Box: No Auxillary Box
Auxillary Box Lead Termination: None
Base Indicator: Rigid
Bearing Grease Type: Polyrex EM (-20F +300F)
Insulation Class: B
Inverter Code: Not Inverter
KVA Code: K
Lifting Lugs: No Lifting Lugs
Locked Bearing Indicator: Locked Bearing
Motor Lead Quantity/Wire Size: 9 @ 18 AWG
Motor Lead Exit: Ko Box
Motor Lead Termination: Flying Leads
Motor Type: 3522M
Mounting Arrangement: F1
Power Factor: 87
Product Family: General Purpose
Pulley End Bearing Type: Ball
Pulley Face Code: C-Face
Pulley Shaft Indicator: Tapped & Key
Rodent Screen: Included
RoHS Status: ROHS COMPLIANT
Blower: None
Shaft Extension Location: Pulley End
Page 2 of 10
![](/html/fa/facd/facd6a4ab71a2dee64de1f49825bffbacaefdf649f7c5af65268b1f11a3791cd/bg3.png)
Product Information Packet: JMM3155T - 2HP,3450RPM,3PH,60HZ,145JM,3522M,OPSB,F1
Current @ Voltage: 2.600 A @ 460.0 V
5.200 A @ 230.0 V
5.600 A @ 208.0 V
Design Code: B
Drip Cover: No Drip Cover
Duty Rating: CONT
Electrically Isolated Bearing: Not Electrically Isolated
Feedback Device: NO FEEDBACK
Front Face Code: Standard
Front Shaft Indicator: None
Heater Indicator: No Heater
Shaft Ground Indicator: No Shaft Grounding
Shaft Rotation: Reversible
Shaft Slinger Indicator: Shaft Slinger
Speed Code: Single Speed
Motor Standards: NEMA
Starting Method: Direct on line
Thermal Device - Bearing: None
Thermal Device - Winding: None
Vibration Sensor Indicator: No Vibration Sensor
Winding Thermal 1: None
Winding Thermal 2: None
Page 3 of 10