![](/html/68/681d/681d0e98fce68ab177a8b21031fd9034074aa85b82862d2b18cf6edad4b12350/bg1.png)
Product Information Packet
IDXM7014T
1HP,1760RPM,3PH,60HZ,143TC,3520M,XPFC,F1
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
![](/html/68/681d/681d0e98fce68ab177a8b21031fd9034074aa85b82862d2b18cf6edad4b12350/bg2.png)
Product Information Packet: IDXM7014T - 1HP,1760RPM,3PH,60HZ,143TC,3520M,XPFC,F1
Part Detail
Revision: K Status: PRD/A Change #: Proprietary: No
Type: AC Elec. Spec: 35WGM492 CD Diagram: CD0005 Mfg Plant:
Mech. Spec: 35N256 Layout: 35LYN256 Poles: 04 Created Date: 11-04-2013
Base: RG Eff. Date: 12-27-2018 Leads: 9#18
Specs
Catalog Number: IDXM7014T
Enclosure: XPFC
Frame: 143TC
Frame Material: Steel
Output @ Frequency: 1.000 HP @ 60 HZ
Synchronous Speed @ Frequency: 1800 RPM @ 60 HZ
Voltage @ Frequency: 460.0 V @ 60 HZ
230.0 V @ 60 HZ
XP Class and Group: CLI GP D; CLII GP F,G
XP Division: Division I
Agency Approvals: UR
CSA EEV
CSA
Auxillary Box: No Auxillary Box
Auxillary Box Lead Termination: None
Base Indicator: Rigid
Bearing Grease Type: Polyrex EM (-20F +300F)
Insulation Class: F
Inverter Code: Inverter Duty
KVA Code: L
Lifting Lugs: No Lifting Lugs
Locked Bearing Indicator: Locked Bearing
Motor Lead Quantity/Wire Size: 9 @ 18 AWG
Motor Lead Exit: Ko Box
Motor Lead Termination: Flying Leads
Motor Type: X3520M
Mounting Arrangement: F1
Power Factor: 71
Product Family: General Purpose
Pulley End Bearing Type: Ball
Pulley Face Code: C-Face
Pulley Shaft Indicator: Standard
Rodent Screen: None
RoHS Status: ROHS COMPLIANT
Blower: None
Shaft Extension Location: Pulley End
Page 2 of 10
![](/html/68/681d/681d0e98fce68ab177a8b21031fd9034074aa85b82862d2b18cf6edad4b12350/bg3.png)
Product Information Packet: IDXM7014T - 1HP,1760RPM,3PH,60HZ,143TC,3520M,XPFC,F1
Constant Torque Speed Range: 6
Current @ Voltage: 1.500 A @ 460.0 V
3.000 A @ 230.0 V
3.100 A @ 208.0 V
Design Code: B
Drip Cover: No Drip Cover
Duty Rating: CONT
Electrically Isolated Bearing: Not Electrically Isolated
Feedback Device: NO FEEDBACK
Front Face Code: Standard
Front Shaft Indicator: None
Heater Indicator: No Heater
Shaft Ground Indicator: No Shaft Grounding
Shaft Rotation: Reversible
Shaft Slinger Indicator: No Slinger
Speed Code: Single Speed
Motor Standards: NEMA
Starting Method: Direct on line
Thermal Device - Bearing: None
Thermal Device - Winding: Normally Closed Thermostat
Vibration Sensor Indicator: No Vibration Sensor
Winding Thermal 1: None
Winding Thermal 2: None
XP Temp Code: T3C
Page 3 of 10