Baldor EXPLOSION PROOF MOTORS Catalog

EXPLOSION PROOF MOTORS
NEW!
Explosion proof, 50 Hz, single and three phase
1/3 thru 1 Hp
Features:
· Steel band frame, cast iron endplates
· IP54 ingress protection
· 1.15 service factor on three phase
· Auto thermal overload (<1 Hp), normally closed thermostats (>1 Hp)
· Threaded lead inlet
111
InformationSingle phaseGeneral purpose Severe dutyLarge ACWashdown dutyExplosion proofPumpHVACFarm duty
Applications:
· Customer specified Division 1 hazardous areas
· Fixed speed operation
Hp RPM
Single Phase
1/3 1800 56C CXL050342A-50
1/2 1800 56C CXL050542A-50
3/4 1800 56C CXL050742A-50
1 1800 56C CXL05142-50
Three Phase
1/2 1800 56C CXM050542-57
3/4 1800 56C CXM050742-57
1 1800 56C CXM05142-57
(a) See notes on inside back ap.
Red catalog number indicates NEW product.
NEMA
Frame
Catalog
Number
XP Cls/ Grp
Tem p
Code
② ②
② ② ②
T3C XP1 14.22 35 59.5 110/2 20 2.6 2, 38
T3C XP1 15.22 45 62 110/220 3.6 2, 38
T4 XP1 15.17 52 70 110/220 4.8 2, 38
T3C XP1 16.05 56 68 110/220 6.2 2, 38
T3C XPM 14.2 2 36 73 230/400 1 38
T3C XPM 15.22 42 75.5 230/400 1.7 38
T3C XPM 15.22 45 74 230/400 2 38
Disc.
Sym.
“C”
Dim.
Aprx.
Wt. (lb)
Full Load
Eciency
Voltage
Full
Load
Amps
= Class I, Group D, Class II, Group F & G
Caution: Explosion-proof motors have a tight t bet ween mating parts to ensure the integrity of the explosion-proof enclosure. This can lead to an accumulation of
moisture inside the motors due to condensation. If internal condensation buildup is a concern for your XP motor application, select a motor that includes UL listed breather drain. These explosion-proof motors are not suitable for use with adjustable speed drives. Inverter Duty
®
explosion-proof motor s must be used.
Notes
(a)
NEW!