Baldor EM7081T-I-5 Product Information Sheet

Product Information Packet
EM7081T-I-5
50HP,3560RPM,3PH,60HZ,326TS,1264M,XPFC,F
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
Product Information Packet: EM7081T-I-5 - 50HP,3560RPM,3PH,60HZ,326TS,1264M,XPFC,F
Part Detail
Revision: J Status: PRD/A Change #: Proprietary: No Type: AC Elec. Spec: 12WGY735 CD Diagram: CD0006 Mfg Plant: Mech. Spec: 12T060 Layout: 12LYT060 Poles: 02 Created Date: 11-20-2013 Base: RG Eff. Date: 03-09-2020 Leads: 3#8
Specs
Catalog Number: EM7081T-I-5 Enclosure: XPFC Frame: 326TS Frame Material: Iron Output @ Frequency: 50.000 HP @ 60 HZ Synchronous Speed @ Frequency: 3600 RPM @ 60 HZ Voltage @ Frequency: 575.0 V @ 60 HZ XP Class and Group: CLI GP C,D XP Division: Division I Agency Approvals: UL
UR CSA EEV
CSA Auxillary Box: No Auxillary Box Auxillary Box Lead Termination: None Base Indicator: Rigid Bearing Grease Type: Polyrex EM (-20F +300F)
Inverter Code: Not Inverter KVA Code: K Lifting Lugs: Standard Lifting Lugs Locked Bearing Indicator: Locked Bearing Motor Lead Quantity/Wire Size: 3 @ 8 AWG Motor Lead Exit: Ko Box Motor Lead Termination: Flying Leads Motor Type: X1264M Mounting Arrangement: F1 Power Factor: 89 Product Family: General Purpose Pulley End Bearing Type: Sealed Bearing Pulley Face Code: Standard Pulley Shaft Indicator: Standard Rodent Screen: None Shaft Extension Location: Pulley End Shaft Ground Indicator: No Shaft Grounding
Blower: None
Shaft Rotation: Reversible
Product Information Packet: EM7081T-I-5 - 50HP,3560RPM,3PH,60HZ,326TS,1264M,XPFC,F
Current @ Voltage: 45.000 A @ 575.0 V Design Code: A Drip Cover: No Drip Cover Duty Rating: CONT Electrically Isolated Bearing: Not Electrically Isolated Feedback Device: NO FEEDBACK Front Face Code: Standard Front Shaft Indicator: None Heater Indicator: No Heater Insulation Class: F
Shaft Slinger Indicator: Shaft Slinger Speed Code: Single Speed Motor Standards: NEMA Starting Method: Direct on line Thermal Device - Bearing: None Thermal Device - Winding: Normally Closed Thermostat Vibration Sensor Indicator: No Vibration Sensor Winding Thermal 1: None Winding Thermal 2: None XP Temp Code: T3C