Product Information Packet
EJPM7144T-I-5
5HP,1750RPM,3PH,60HZ,184JP,0641M,XPFC,F1
Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
Product Information Packet: EJPM7144T-I-5 - 5HP,1750RPM,3PH,60HZ,184JP,0641M,XPFC,F1
Part Detail
Revision: F Status: PRD/A Change #: Proprietary: No
Type: AC Elec. Spec: 06WGX200 CD Diagram: CD0006 Mfg Plant:
Mech. Spec: 06H458 Layout: 06LYH458 Poles: 04 Created Date: 05-31-2013
Base: RG Eff. Date: 03-06-2018 Leads: 3#16
Specs
Catalog Number: EJPM7144T-I-5
Enclosure: XPFC
Frame: 184JP
Frame Material: Iron
Output @ Frequency: 5.000 HP @ 60 HZ
Synchronous Speed @ Frequency: 1800 RPM @ 60 HZ
Voltage @ Frequency: 575.0 V @ 60 HZ
XP Class and Group: CLI GP C,D
XP Division: Division I
Agency Approvals: CSA
CSA EEV
UL
UR
Auxillary Box: No Auxillary Box
Auxillary Box Lead Termination: None
Base Indicator: Rigid
Bearing Grease Type: Polyrex EM (-20F +300F)
Inverter Code: Not Inverter
KVA Code: J
Lifting Lugs: Standard Lifting Lugs
Locked Bearing Indicator: Locked Bearing
Motor Lead Quantity/Wire Size: 3 @ 16 AWG
Motor Lead Exit: Ko Box
Motor Lead Termination: Flying Leads
Motor Type: X0642M
Mounting Arrangement: F1
Power Factor: 79
Product Family: General Purpose
Pulley End Bearing Type: Ball
Pulley Face Code: C-Face
Pulley Shaft Indicator: Tapped & Key
Rodent Screen: None
RoHS Status: ROHS COMPLIANT
Shaft Extension Location: Pulley End
Blower: None
Shaft Ground Indicator: No Shaft Grounding
Page 2 of 10
Product Information Packet: EJPM7144T-I-5 - 5HP,1750RPM,3PH,60HZ,184JP,0641M,XPFC,F1
Current @ Voltage: 5.300 A @ 575.0 V
Design Code: B
Drip Cover: No Drip Cover
Duty Rating: CONT
Electrically Isolated Bearing: Not Electrically Isolated
Feedback Device: NO FEEDBACK
Front Face Code: Standard
Front Shaft Indicator: None
Heater Indicator: No Heater
Insulation Class: F
Shaft Rotation: Reversible
Shaft Slinger Indicator: No Slinger
Speed Code: Single Speed
Motor Standards: NEMA
Starting Method: Direct on line
Thermal Device - Bearing: None
Thermal Device - Winding: Normally Closed Thermostat
Vibration Sensor Indicator: No Vibration Sensor
Winding Thermal 1: None
Winding Thermal 2: None
XP Temp Code: T3C
Page 3 of 10