The Baldor Series Controls represent the latest technology in microprocessor
based motor controls. The user programmable parameters available in every
control provides the ability to customize the control to most any application.
Baldor has tried to ensure that the information in this manual is correct at the
time of printing. The information is subject to change without prior notice.
This document is copyright by Baldor and is supplied with the understanding
that it will not be reproduced or disclosed in whole or in part, without the
express permission of Baldor.
Conformity
This product is only for use in industrial applications as described in EN 60204
and VDE 0160. This means use DBSC100 in stationary ground based
applications only
within the meaning of “Safety law of appliance”, “EMC Law” or “Machine
directive”. It is the responsibility of the user to verify that the equipment the
DBSC 100 is used in complies with all applicable regulations.
The DBSC 100 Series AC Servo Control is intended for use in industrial
installations. These controls are designed for applications that require speed
control of three phase AC Servo motors.
The DBSC 100 conforms to the following standards:
. It is a component only and is not intended for immediate use
DIN VDE 0100
DIN VDE 01
DIN VDE 0160
DIN IEC 326
EN 60529
MN1229
10
Power installations with nominal voltages
Dimensioning of clearance tolerances.
Electronic equipment for use in electrical power
installations.
Design and use of printed circuit boards.
Degrees of protection provided by enclosure.
≤ 1000 VAC.
1–1
Section
Limited Warranty
For
a period of one (1) year from the date of
or replace without charge controls which our examination proves to be defective in
material
or workmanship. This warranty is valid if the unit has not been tampered
with by unauthorized persons, misused, abused, or improperly installed and has
been used in accordance with the instructions and/or ratings supplied. This
warranty is in lieu of any other warranty or guarantee expressed or implied.
BALDOR
removal),
or
property caused by items of our manufacture or sale. (Some states do not allow
shall not be held responsible for any expense (including installation and
inconvenience, or consequential damage, including injury to any person
exclusion or limitation of incidental or consequential damages, so the above
exclusion may not apply.) In any event, BALDOR’s total liability, under all
circumstances,
purchase
shall not exceed the full purchase price of the control. Claims for
price refunds, repairs, or replacements must be referred to BALDOR
all pertinent data as to the defect, the date purchased, the task performed by the
control,
and the problem encountered. No liability is assumed
such as fuses.
Goods
may be returned only with written notification including a BALDOR
Authorization Number and any return shipments must be prepaid.
original purchase, BALDOR will repair
with
for expendable items
Return
1–2
MN1229
Section
Safety Notice
This equipment contains high voltage. Electrical shock can cause serious or
fatal injury. Only qualified personnel should attempt the start-up procedure or
troubleshoot this equipment.
This equipment may be connected to other machines that have rotating parts or
parts that are driven by this equipment. Improper use can cause serious or
fatal injury. Only qualified personnel should attempt the start-up procedure or
troubleshoot this equipment.
PRECAUTIONS
WARNING: Do not touch any circuit board, power device or electrical
connection before you first ensure that power has been
disconnected and there is no high voltage present from
this equipment or other equipment to which it is
connected. Electrical shock can cause serious or fatal
injury. Only qualified personnel should attempt the
start-up procedure or troubleshoot this equipment.
WARNING: Be sure that you are completely familiar with the safe
operation of this equipment. This equipment may be
connected to other machines that have rotating parts or
parts that are controlled by this equipment. Improper use
can cause serious or fatal injury. Only qualified personnel
should attempt the start-up procedure or troubleshoot this
equipment.
WARNING: Be sure all wiring complies with the National Electrical
Code and all regional and local codes. Improper wiring
may result in unsafe conditions.
WARNING: Be sure the system is properly grounded before applying
power. Do not apply AC power before you ensure that all
grounding instructions have been followed. Electrical
shock can cause serious or fatal injury.
MN1229
1–3
Section
WARNING: Do not remove cover for at least five (5) minutes after AC
power is disconnected to allow capacitors to discharge.
Dangerous voltages are present inside the equipment.
Electrical shock can cause serious or fatal injury.
WARNING: Improper operation of control may cause violent motion of
the motor shaft and driven equipment. Be certain that
unexpected motor shaft movement will not cause injury to
personnel or damage to equipment. Peak torque of
several times the rated motor torque can occur during
control failure.
WARNING: Motor circuit may have high voltage present whenever AC
power is applied, even when motor is not rotating.
Electrical shock can cause serious or fatal injury.
Caution:To prevent equipment damage, be certain that the
electrical service is not capable of delivering more than
the maximum line short circuit current amperes listed in
this manual.
Caution:To prevent equipment damage, be certain that the input
power has correctly sized protective devices installed as
well as a power disconnect.
Caution:To prevent equipment damage, DO NOT connect a 24VDC
source to terminal strip X2 if the 24 Volt option is not
installed. If you apply 24VDC to X2 without the option, the
control will be damaged.
1–4
MN1229
Section 2
Specifications
Identification
DBSC 1XX - XXX - X
Digital
Baldor
Series
Servo Control
Code Input
A
B
E
F
Code
A
B
Code
A
B
Code
Blank
1
2
3
Control Options
Pulse & Direction with RS-232
Pulse & Direction with RS-422/RS485
Electronic Handwheel (Pulse Follower)
with RS-232
Electronic Handwheel (Pulse Follower)
with RS-422/RS485
Feedback Options
Standard Resolver
Encoder
Field Bus Options
None
CAN Bus
Input Control Options
Standard 230 V
1
15 V
AC 1O Input Power
Optional external 24 VDC Logic Input
(Customer Provided)
1
15 V
AC 1O Input Power and
External 24 VDC Logic Input
AC Input Power
Code Current
02052.5 Amps
5 Amps
MN1229
2–1
Section
General Specifications - 230VAC
DescriptionUnitDBSC102-AAADBSC105-AAA
Input Voltage Range
(230V
AC 1O Nominal)
Input FrequencyHz50/60 ±5%
Nominal Output Bus (Range)
Nominal Current (
Peak Phase Current (±10%); 2.5s