Balcrank 3331-019 Operation, Installation, And Maintenance Manual

Page 1
SERVICE BULLETIN SB3057
Rev D 4/12
®
RF ELECTRONIC
PRESET METER
Model 3331-019
Thoroughly read and understand this manual before installing, operating or servicing this equipment.
OPERATION, INSTALLATION,
MAINTENANCE AND REPAIR GUIDE
Page 2
Disclaimer
The user/purchaser is expected to read and understand the information provided in this manual, follow any listed Safety Precautions and Instructions and keep this manual with the equipment for future reference.
The information in this manual has been carefully checked and is believed to be entirely reliable and consistent with the product described. However, no responsibility is assumed for inaccuracies, nor does Balcrank Products, Inc. assume any liability arising out of the application and use of the equipment described.
Should the equipment be used in a manner not specied by Balcrank Products, Inc., the
protection provided by the equipment may be impaired.
Questions or Service Assistance
If you have questions regarding the product or this document contact:
Balcrank Products, Inc. 115 Reems Creek Rd. Weaverville, NC 28787
Telephone: (828) 645-4261 (800) 747-5300
Fax: (828) 658-0840 (800) 763-0840
On the Web: www.balcrank.com or call your local Balcrank Products, Inc. representative.
Product Identication Information
Record the product identication numbers from the nameplate here.
Model Number _______ Serial Number _____________ Tag Number _______________(if applicable)
Page 3
Table of Contents
DISCLAIMER.......................................................................................................Back of front cover
QUESTIONS or SERVICE ASSISTANCE............................................................Back of front cover
PRODUCT IDENTIFICATION INFORMATION....................................................Back of front cover
Table of Contents.................................................................................................................................
Explosions and Fire Hazards...................................................................................
Meter Hazards............................................................................................................
Designed for Special Fluids ....................................................................................
FCC Compliance..................................................................................................................................
METER OVERVIEW ...........................................................................................................................1
Meter Buttons.........................................................................................................................1
LCD Display ...........................................................................................................................2
METER INSTALLATION.....................................................................................................................2
Relieve System Pressure......................................................................................................2
Grounding..............................................................................................................................2
Flushing Procedure...............................................................................................................3
Apply Meter to Hose..............................................................................................................3
Apply Nozzle to Meter............................................................................................................4
METER OPERATION, RF MODE.......................................................................................................4
History Icon ...........................................................................................................................5
Error Codes............................................................................................................................6
METER OPERATION, EPM MODE....................................................................................................7
Manual Mode..........................................................................................................................7
Batch Mode............................................................................................................................7
Return to RF Mode.................................................................................................................8
OPERATING MODE FUNCTIONS .....................................................................................................9
Re-settable/Accumulated Totals...........................................................................................9
Emergency Override..............................................................................................................9
SERVICE ..........................................................................................................................................10
Low Battery .........................................................................................................................10
Changing the Battery ..........................................................................................................10
CHANGE FACTORY SETTINGS......................................................................................................11
Programming Verson 17 & Below..............................................................................11 & 12
Programming Verson 18 or higher............................................................................13 & 14
CALCULATE SCALE FACTOR .................................................................................................15
Absolute Scale Factor.........................................................................................................15
Chart of Scale Factors.........................................................................................................16
Sample Fluids, Viscosities and Scale Factors..................................................................16
Specications..................................................................................................................................17
Parts Drawings.......................................................................................................................18 to 20
Troubleshooting .............................................................................................................................21
Page 4
EXPLOSION and FIRE HAZARDS
Improper grounding, poor ventilation, open ames or sparks can cause a hazardous condition and result in an explosion or re and cause serious injury.
• Be sure the uid system is properly grounded. See your pump instruction manual for
details.
• If there is static sparking or if you feel an electric shock while using the meter, stop dis
pensing immediately. Identify and correct the problem before continuing.
• Provide fresh air ventilation. This will avoid the buildup of fumes from the uid being dis
pensed.
• Do not smoke while dispensing ammable uids.
• Keep the dispensing area free of debris including solvents, rags and spilled gasoline.
METER HAZARDS
Equipment misuse can cause the meter to rupture or malfunction and cause serious injury.
• This equipment is for professional use only.
• Read all instructions, tags and labels before operating the equipment.
• Use the equipment only for its intended purpose.
• Do NOT modify or alter the equipment.
• Do NOT leave equipment unattended while dispensing.
• Check equipment daily. Repair or replace worn or damaged parts immediately.
• Do NOT exceed the maximum working pressure level of the lowest rated system comp
nent.
• Use only extensions and nozzles that are designed for use with this equipment.
• Use only uids and solvents that are compatible with the equipment. Read all uid and
solvent manufacturer’s warnings.
• Tighten all uid connections before operating this equipment.
• Do NOT stop or deect leaks with hands, body, gloves or rags.
• Do NOT dispense towards any person or any part of the body.
• Do NOT place hands or ngers over the end of or into the dispense valve.
• Comply with all local, state, and federal re, electrical and safety regulations
• Use of this product in a manner other than specied in this manual may result in impaired
operation or damage to equipment.
This meter is designed specically to dispense antifreeze (ethylene glycol) solution, windshield wiper uid, brake uid and water based solution.
DO NOT USE FOR PETROLEUM PRODUCTS.
FCC CERTIFIED, PART 15, SUB-PART C
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired opera­tion.
FCC ID: GIF-RF2 KEYPAD
Page 5
METER OVERVIEW
The Electronic Preset Meter RF2 (EPM RF2) is equipped with RF (radio frequency) communications to communicate with a uid management system keypad to get authoriza­tion and dispense information. This is referred to in the manual as the RF2 Mode.
The meter can also be run as a standard EPM. This is referred to in the manual as the EPM
Mode. This is intended for start-up purposes or when the uid management system is not in
use.
Once a work order has been entered at the keypad, the operator simply pushes the button on the meter to start communications between the meter and the keypad. The meter
receives authorization from the keypad to unlock and the dispense batch quantity. When
the trigger is pulled the pre-set dispense batch quantity dispenses.
The meter automatically shuts off when the dispense batch quantity has been reached.
A “Top Off” feature allows additional uid to be dispensed and tracked after the batch quan­tity has been dispensed.
Upon completion of the dispense, the operator presses the button. The meter then
locks, prohibiting any unauthorized dispense of uid and the dispense quantity is sent to
the keypad.
Meter Buttons
Meter Display
Reset
Used to initiate RF2 communications from the meter to the Keypad.•
Used in EPM mode to clear the previous batch.• Used to reset the re-settable total dispensed while pressing the TOTAL button.•
Used to enter the dispense Batch quantity when in the EPM Mode. These buttons are NOT used in RF2 mode.
Total
Used to display the accumulated total of uid dis­pensed, as well as the re-settable total.
Auto
Used to enter and exit the manual or batch mode when in EPM mode. This button is NOT used in RF2 mode.
Shut-Off or Stop
Used to stop the ow through an Emergency Override.
1
Page 6
LCD Display
1
7 6 5 4
LCD Display
2
3
METER INSTALLATION
Relieve System Pressure
1. Turn off the power supply to the pump or close the shutoff valve.
2. Dispense any uid in the system into a
waste container by opening the meter(s).
3. Open all bleed-type master air valves
and uid meter(s) in the system.
4. Leave the meter(s) open until ready to
pressurize the system.
Grounding
1. Displays re-settable total, accumulated total and Scale Factor
2. Displays Unit of Measure
3. Arrows ash when RF communication is in
progress with the keypad
4. Preset Batch quantity
5. History Icon
6. AUTO is an indicator of being in EPM mode
7. Low Battery Icon
Pressurized Equipment
This equipment stays pressurized until the
pressure is manually relieved. To reduce the
risk of injury from uid spray from the meter
follow the Pressure Relief Procedures when you:
• Are instructed to relieve pressure
• Stop dispensing
• Check, clean, or service any system
equipment
• Clean or install nozzles
1. Grounding reduces the risk of static sparking. Ground all system components according to local, state, and federal codes. Consult the pump user’s manual and other system components to ground the following:
2. Pump: follow manufacturer’s recommendations
3. Air and Fluid Hoses: use only grounded hoses
4. Air Compressor: follow manufacturers recommendations
5. Fluid Supply Container: follow the local code
Explosion and Fire
Movement of uids through the dispensing
system creates static electricity. Static electricity can cause volatile fumes result-
ing in an explosion and re. The dispensing
system must be grounded.
2
Page 7
Flushing Procedure
NOTE: If the system has multiple dispense
positions, begin at the position farthest from the pump and move towards the pump.
If this installation is new or if the uid in the lines is contaminated, ush the
system before installing the meter(s).
1. Close uid dispense valves at every position.
2. Once the main uid outlet valve at the pump is closed, the air pressure to the pump motor is properly adjusted and the air valve is opened.
3. Slowly open the main uid valve.
4. Place the hose end in a waste container. Make sure hose is secure so no uid leaks during ushing.
5. Slowly open the dispense valve and allow enough uid to pass through it to ensure that
the system is clean.
6. Close the valve and repeat for all dispense positions.
Apply Meter to Hose
Close the drain valve before starting this procedure.
1. Attach a swivel to the meter. Apply thread sealant to the male end of hose. Recommended sealant is Loctite® 243.
Attach the hose
2. Insert the metal end of the hose into the swivel.
Tighten completely with an open ended, adjustable,
wrench.
NOTE: The threaded end of the meter always has female threads. The metal end of the hose must have male threads.
Apply thread sealant, Loctite® 243, or equivalent, to the male end.
The inlet and outlet swivel connections are either 1/2” NPT or 1/2” BSPP, depending on meter model.
3
Page 8
Apply Nozzle to Meter
1. On the opposite end, apply sealant to the
end of the nozzle. Recommended sealant
is Loctite® 243.
2. Thread the nozzle onto the meter. Screw it in rmly with an open ended, adjust
able, wrench (see caution below).
CAUTION
Do Not Over Tighten nozzle to handle. This may result in cracking
the handle housing.
3. Open all dispense position shut-off
valves. Start the pump to pressurize the
system.
4. Before use, to ensure accuracy, purge
all air from the uid lines and dispense
valve(s).
Attach the Nozzle
METER OPERATION, RF MODE
When the battery pack is attached to the meter, it automatically enters the RF Mode.
The trigger is in the locked-out position. No uid can be dispensed by the meter until a dis­pense order is received from the keypad.
1. Pressing the meter button causes communication to occur
Arrows
Batch Quantity
between the meter and the keypad.
• Two (2) arrows in the lower right
hand corner of the meter screen
ash. This indicates communication
is in progress between the meter and keypad.
2. When the communication is complete the trigger unlocks and the batch quantity is displayed
4
Page 9
3. Pull the trigger to the full, up, position to begin the uid ow. Release trigger once uid ow begins.
• The solenoid valve automatically locks the dispensing valve in the full open posi-
tion. The trigger falls back to the closed position.
• It is not necessary to continue to hold the trigger.
• After the batch quantity is dispensed, the ow automatically shuts off.
4. The user has the option to top off the tank after the batch quantity has been dispensed.
• To top off, pull the trigger to begin the ow.
• Release the trigger when the desired amount
has been dispensed.
Do NOT press button before topping off.
If button is pressed, the meter returns to a locked-out position and
does not allow additional uid to be
dispensed until a valid dispense order is received from the RF System.
5. Press the button when nished to complete the dispense order.
• The total quantity dispensed is transmitted to the RF2 system.
• The meter returns to the locked position.
• The meter is now ready to receive another dispense order from the RF2 system.
NOTE: If the original communication fails, the meter automatically attempts to communicate with the RF2 system by resending the Dispense Result three (3) times, 30 seconds apart.
6. If the meter is unable to communicate a dispense result, the History icon lights.
History Icon
The History icon indicates there is dispense result information that has not been communicated to the keypad to complete a work order.
To send the dispense result information to the keypad, press button to initiate communication.
History Icon
5
Page 10
Error Codes
The meter has several Error Codes that may be displayed. These provide indication, at the meter, that there is an error in communication between the meter and keypad.
F01 The meter has received an invalid response from the keypad.
• To clear the error, press the Reset button on the meter.
• Press the Reset button a second time to retry communications with the keypad.
F02 The meter has not received a response from the keypad during communications.
• To clear the error code, press the Reset button on the meter.
• To retry communications with the keypad, press the Reset button a second time.
• There may be an obstruction blocking the RF2 signal between the meter and keypad.
It may be necessary to change your physical location.
F04 There is a damaged cable assembly within the meter.
• This meter should be taken out of service.
• This meter may be used reliably in EPM Mode.
• RF2 Mode will exhibit erratic behavior.
SF0 (Scale Factor 0) The Scale Factor setting for the meter is set to 0.000.
• To input a valid Scale Factor for the meter follow the instructions in the Change Factory Settings section of this manual.
All other Error Codes are for factory purposes only.
• To clear the meter, press Reset.
6
Page 11
METER OPERATION, EPM MODE
The meter can be put in EPM Mode for start up purposes. Refer to the Supervisor’s Instruc­tion Manual for key sequence.
The AUTO icon displays, indicating the meter is in the EPM Mode. The solenoid valve unlocks and the meter can now be used as a Standard Preset Batch Meter.
NOTE: The keypad AUTO button is used to toggle between Manual Mode and Batch Mode.
Manual Mode
1. Pull the trigger to begin the ow.
2. The display shows the amount dispensed.
3. When the desired amount has been dispensed,
release the trigger to stop the ow.
4. Press button once to reset the counter
display to zero.
EPM Manual Mode
Batch Mode
To enter the Batch Mode from the Manual Mode press the meter button. The screen on the left appears. When in the Batch Mode, the batch quan­tity displays in the lower, right hand corner of the screen.
The meter is now in Batch Mode.
EPM Batch Mode
1. Change the batch size by pressing the , and/or buttons.
a) Press the 10 button to increase the batch amount in increments of 10 units. b) Press the 1 button to increase the batch amount in increments of 1 unit. c) Press the 0.1 button to increase the batch amount in increments of 0.1 units.
7
Page 12
2. Pull the trigger to begin the ow.
• The meter solenoid valve automatically
Batch
Size
locks the dispensing valve in the full open position. The trigger falls back to the closed position.
The meter always locks in the maximum open position.
• After the batch quantity is dispensed, the ow automatically shuts off.
NOTE: For RF2 and BATCH programming, the meter automatically shuts off if the trigger is
pulled and the meter does not sense any ow.
Also, in case of an emergency or to interrupt a batch, the meter is equipped with an Emergency Override. (See the Emergency Override section of this manual.)
3. The user has the option to top off the uid at the end of a batch.
• To top off the uid, pull the trigger to begin the ow and release it when the desired
amount has been pumped.
4. Press the button when nished. The display resets and the meter is now ready for
the next batch to be dispensed.
Return to RF Mode
To return to the RF Mode from the EPM Mode:
1. Press button twice. You’ll see the
Arrows
ashing arrows indicating the meter is
communicating with the RF2 System.
2. When communication is complete, the meter returns to the RF2 Mode and the trigger locks.
8
Page 13
OPERATING MODE FUNCTIONS
These functions operate the same in RF2 Mode and EPM Mode.
Re-settable/Accumulated Totals
The meter has two ow totalizers. One is Re-settable Total the other is Accumulated Total.
1. To see the Accumulated Total and the Re-settable Total:
• Press and hold the button to see the Accumulated Total.
• Continue holding the button.
• After three seconds the screen changes to the Re-settable Total.
2. Resettotal displays the total uid dispensed since the Resettable Total was last set back to zero.
3. Press the button while viewing Resettotal to
set it back to zero.
4. Release the button to return to the operating display.
Re-settable Total
NOTE: The Accumulated Total cannot be reset unless the user changes from English units to metric units or from metric to English units. (See the Change Factory Settings, Change Unit of Measure section of this manual).
Emergency Override
In case of an emergency or to interrupt a batch, the meter is equipped with an Emergency Override.
1. Press the red button to activate the Emergency Override. The override closes the
valve, immediately stopping uid ow.
2. Batching can continue after an Emergency Override by pulling up on the trigger.
9
Page 14
SERVICE
Low Battery
When the batteries need changing a progression of warnings appears on the meter screen.
First Warning: the Low Battery icon appears in the lower left corner of the display. That means the batteries are low and need to be changed when the icon appears.
Second Warning: Battery icon ashes. The battery
power is too low and meter functions are disabled.
Low Battery
Icon
Changing the Batteries
The battery compartment is located in the lower case on the underside of the trigger guard.
1. Turn the unit over.
2. Unscrew the two screws. Remove the battery door to expose the batteries.
3. Replace the old batteries. The meter takes 4 AA, alkaline, batteries.
NOTE: Battery polarity markings are inside battery compartment.
4. Dispose of used batteries properly, according to local regulations.
NOTE: Changing the batteries does not affect any of the programmed values or totals.
10
Page 15
CHANGE FACTORY SETTINGS
Each meter is calibrated at the factory for use with motor oil (see the Change Scale Factor section of this manual). The Unit of Measure is also selected prior to shipment.
Verify Firmware Version
1. The rmware version and code checksum can be displayed by
holding the and button at the same time.
2. The last two digits on the lower right are the rmware version.
3. Meters with version 17 and below use the procedure outlined in Programming Version 17 & below in this manual for changing of unit of measure, scale factor and enabling or disabling the EPM functionality.
4. Meters with version 18 or higher use the procedure outlined in Programming Version 18 or higher in this manual for changing of unit of measure, scale factor and enabling or disabling the EPM functionality.
Programming Version 17 & below
To change the factory settings:
Use a 5/32” Allen wrench or similar blunt tool.
1. Press the button to wake up the meter if the display is blank.
2. To enter the Programming mode turn the unit over. Press and hold down the “PROGRAMMING” key located in the access hole for 2 seconds (see picture on left).
3. After the display ashes, the Unit of
Measurement and Scale Factor are displayed.
4. The current Unit of Measurement will
be ashing when the programming
mode has been entered.
Location of access hole for PROGRAMMING Key
Change Unit of Measure
The meter comes with an option to choose 4 different Units of Measure.
Scale Factor Digits
1. The actual Unit of Measure is ashing
when the Programming Mode is entered.
Programming
Display
Unit of Measurement
11
2. Press the button to toggle between the four options; PT, QT, GAL, L.
3. When the desired unit of measure is
displayed, press the button. The
Unit of Measure icon stops ashing.
Page 16
4. If L, (Liters), is selected, the decimal point begins to ash.
• You now have the option to change the decimal point to either a period or a comma.
• To do this, press the button.
5. If no Scale Factor changes are necessary, refer to the Save Changes section of this manual.
Changing the Unit of Measurement from metric to English or from English to metric clears the Re-settable Total and Accumulated Total.
Change Scale Factor
Changing the Scale Factor changes the accuracy of the meter, potentially causing it to
overll or under ll. This has the potential to cause a mechanical breakdown.
Scale Factor Digits
1. Press the button to advance through the Scale Factor digits.
2. Press the button to change the selected number.
NOTE: All digits can be scrolled between 0 and 9
except the rst. It can only be scrolled from 0 to 1
or from 1 to 0.
Scale Factor Display
3. Press the button to advance to the next number in Scale Factor.
4. Repeat steps 2 and 3 for all ve digits in Scale Factor.
Save Changes
When you are nished programming these options, turn the unit over and press the
PROGRAMMING key.
1. Hold the PROGRAMMING key until the display ashes three times and goes blank.
2. Press the button to turn the meter display on.
Verify Changes
1. Verify Unit of Measure is correct.
2. Push and hold the button and button together, to verify that the Scale Factor is correct.
12
Page 17
Programming Version 18 or higher
To change the factory settings:
1. Push and hold at the same time the and buttons.
2. PrG will appear on the display.
3. Release the and buttons.
4. Then press and release in order the , , ,
and the buttons
5. The current unit of measure will now be ashing indicating that
you have entered the programming mode.
Change Unit of Measure
The meter comes with an option to choose 4 different Units of Measure.
Scale Factor Digits
1. The actual Unit of Measure is ashing when the
Programming Mode is entered.
2. Press the button to toggle between the four
Unit of
options; PT, QT, GAL, L.
Measurement
3. When the desired unit of measure is displayed,
Programming
Display
press the button. The Unit of Measure icon
stops ashing.
4. If L, (Liters), is selected, the decimal point begins to ash.
• You now have the option to change the decimal point to either a period or a comma.
• To do this, press the button.
5. If no Scale Factor changes are necessary, refer to the Save Changes section of this manual.
Changing the Unit of Measurement from metric to English or from English to metric clears the Re-settable Total and Accumulated Total.
13
Page 18
Change Scale Factor
Changing the Scale Factor changes the accuracy of the meter, potentially causing it to
overll or under ll. This has the potential to cause a mechanical breakdown.
Scale Factor Digits
1. Press the button to advance through the Scale Factor digits.
2. Press the button to change the selected number.
NOTE: All digits can be scrolled between 0 and 9 except
the rst. It can only be scrolled from 0 to 1 or from 1 to 0.
Scale Factor Display
3. Press the button to advance to the next number in Scale Factor.
4. Repeat steps 2 and 3 for all ve digits in Scale Factor.
5. If no other changes are necessary, refer to the Save Changes section in the manual.
EPM (MANUAL) Mode enable/disable
To disable or enable the EPM mode of the meter:
1. Press the button to advance to the AUTO icon on the display, there will be no
other icons ashing on the display.
2. Then press the button to toggle on and off the AUTO icon. When the icon is turned on the meter can be put in EPM mode through the special key sequence on the meter keypad. When the AUTO icon is turned off the key sequence is disabled and the meter cannot be put in EPM mode.
Save Changes
To Save Changes and exit the programming mode:
1. Push and hold at the same time the and buttons.
2. The display will ash 3 times and go blank.
3. Press the button and the display will turn back on.
Verify Changes
1. Verify Unit of Measure is correct.
2. Push and hold the button and button together, to verify that the Scale Factor is correct.
14
Page 19
CALCULATE SCALE FACTOR
A Scale Factor is a number used to adjust meter accuracy. The Scale Factor is set at the
factory using motor oil with a viscosity of 10W.
The primary use for Scale Factor recalibration is to batch uids with different viscosities. If the uid has a lower viscosity, more uid can slip past the meter gears without being detected. Changing the Scale Factor adjusts the meter to compensate for the loss.
The meter multiplies each pulse by the Scale Factor number to correct the accuracy when it
converts to the specied units. The reading is then always correct.
For an approximate Scale Factor for uids of different viscosities, consult the charts on the
next page.
NOTE: The meter’s original Scale Factor was written on the trigger when it was calibrated
at the factory. It may have been revised after eld installation. Use the Scale Factor
showing on the display, not on the trigger.
Changing the Scale Factor changes the accuracy of the meter, potentially causing it to
overll or under ll. This has the potential to cause a mechanical breakdown.
To view the current Scale Factor:
1. Press and hold the button and the button at the same time.
Absolute Scale Factor
For absolute Scale Factor, perform this test:
1. Run a measured amount of uid through the meter.
2. If the meter delivers 4.20 quarts and the display shows only 4.00 quarts, then the Scale
Factor needs to be adjusted.
3. Divide what the meter delivered (4.20) by what the display shows (4.00). You get an error factor of (1.05).
4. The existing Scale Factor is 1.0123, as shown in steps 1 and 2 in “To view the current Scale Factor”, above.
5. To calculate a new factor: 1.0123 (existing Scale Factor) x 1.05 (error factor) = 1.0629 (new Scale Factor).
6. Enter that number as described in the Change Scale Factor section of this manual.
NOTE: Use the Scale Factor showing on the display, not on the trigger.
15
Page 20
Chart of approximate Scale Factors for uids of different viscosities
Scale Factor
Scale Factor
Viscosity in Centistokes @ 65
o
Samples of Fluids, Viscosities and Scale Factors
Fluid Viscosity Scale Factor
1 Water/Anti-Freeze 5 1.044 2 Anti-Freeze 18 1.007 3 Brake Fluid 42 1.004 4 ATF 80 1.002 5 10W 140 1.000 6 80W-90 450 0.999 7 140W 1800 0.993
16
Page 21
Specications English Metric
Maximum Flow* 10 gpm 38 lpm Minimum Flow* 0.25 gpm 1 lpm Operating Pressure (Maximum) 1000 psi 67 bar Operating Pressure (Minimum) 5 psi .35 bar Operating Temperature (Maximum) 120o F 50o C Operating Temperature (Minimum) 20o F -5o C Accuracy - Oils +/- 0.5% +/- 0.5% Accuracy - Anti-Freeze +/- 1.5% +/- 1.5% 5-Digit LCD Display, 10 mm High x
5 mm wide Inlet and Outlet Connections 1/2” NPT 1/2” BSPP
Quarts, Pints, Gallons Liters
17
Page 22
ITEM# PART DESCRIPTION
1 Battery Holder Assembly 2 Bottom Case with Screws
18
Page 23
1
2
3
ITEM# PART DESCRIPTION Part Number
1 Rubber Boot 2 Display Assembly 3 RF Register Assembly
Not Shown Swivel, NPT, Special Fluids 832935
19
Page 24
2
1
ITEM# PART DESCRIPTION
3
1 Valve Assembly 2 Gear Service Kit with O-ring 3 Trigger Assembly
20
Page 25
TROUBLESHOOTING
Relieve the pressure prior
to checking or repairing the meter. Make sure all valves, controls and pumps are operating correctly.
Symptom Possible Cause Remedy
Battery Icon is displayed Batteries are low Replace batteries Display Blank Meter asleep
Push reset button
Loose battery connection
Batteries Dead
Meter does not latch for
Meter not in AUTO mode
batching
Meter not reset after prior batch
Low batteries
Slow or no uid ow Filter is clogged
Pump pressure is low
Remove battery pack and check battery connection/ Push reset button
Replace batteries/Push reset button
Press AUTO button and pro-
gram batch size
Press RESET button
Check for battery icon/ replace batteries/push RESET button
Clean or replace the lter in
the swivel nut
Turn up the pump pressure
Meter inaccurate Scale factor not correct for uid Enter program mode, check
Batch overruns program value
Foreign material is jamming
meter
Contact your local distributor for repair
and reset program factor
Pulse delay value set too low Enter program mode, reset
pulse delay to higher value
21
Page 26
For Warranty Information Visit:
www.balcrank.com
Balcrank® Products, Inc. 115 Reems Creek Road Weaverville, NC 28787 800-747-5300 800-763-0840 Fax www.balcrank.com
SERVICE BULLETIN SB3057 Rev D 4/12
Distributed by:
Revision Log:
New Release - 12/07 Rev. A - 8/08 Added programming instructions for version 18 and Updated Warranty Statement
Rev. B - 12/08 - Added caution about tightening nozzle on
page 4 Rev. C - 6/17 Added part number for swivel on pg. 19 Rev. D - 4/12 Updated warranty information