BALCO ILLUMITREAD 1531 Installation Instructions Manual

BALCO, INC. ILLUMITREAD
TM
PHOTOLUMINUMESCENT EXIT DOOR,
PANIC BAR, MODEL 1531
Installation Instructions
The following installation instructions are very important. Read them carefully, and be sure you understand them completely before you begin any work. Store this product in the horizontal position in a clean, dry location. Store this product in a protected area. Minimum light exposure level necessary to achieve photoluminescence of the signs is 1 Foot Candle.
Figure 1
Tools required :
This is a list of tools and materials recommended for use in the installation of these directional signs. These tools and materials are not provided by Balco, Inc. A. Clean Rags B.Tape Measure C. Isopropyl Alcohol D. Clean Bucket (for alcohol/water mix)
PROCEDURES:
These instructions are applicable to Exit Door, Panic Bars, model 1531. Install indoors only in a location not exposed to direct sunlight, liquid spray or temperatures outside the range of 50oF - 104oF (10oC - 40oC). Ensure temperature of both the directional sign and the surface to receive it is 60oF or higher at the time of installation. These panic bars are aluminum sheet to which photoluminescent coating is applied. The installer shall select the installation means suited to the substrate. STEP 1. Ensure that the surface to receive the directional sign is free of dust, oil and other contaminants. Wipe most aluminum, steel acrylic, polycarbonate, and painted/sealed substrates to receive the directional sign with a 50/50 solution of isopropyl alcohol and water. Routinely replace cleaning cloth to insure proper cleaning. Some glossy surfaces (certain paints and expanded rigid PVC board) may
Parts:
1. Directional Sign
benefit from slight scuffing with a mild abrasive pad prior to cleaning with the ispropyl alcohol/water mixture. Allow the alcohol/water solution used to clean the substrate to evaporate from the substrate prior to applying the directional sign.
oils or grease are present, a “degreasing” solvent such as 3M™ Prep Solvent 70, 3M™ Citrus Base Cleaner, mineral spirits, naphtha or similar solvents are suggested to cut the oil. This should always be followed with an isopropyl alcohol/water cleaning to help ensure that any residue or film is removed.
Follow the applicable MSDS instructions for handling, storage and use of whichever primer or solvent is selected.
STEP 2. Select the means of attachment. For Balco, Inc. Photoluminescent Exit Door, Panic Bars, an adhesive that the installer has determined to be
Where heavy
Balco, Inc., 2626 S. Sheridan, PO Box 17249, Wichita, KS 67217 P (316) 945-9328; F (316) 945-0789; www.balcousa.com
ESI1531
08/07/12
satisfactory for the sign installation may be used. As an alternative, VHB tape or a double-sided tape which the installer has determined to be suitable may be used to affix the signs to the substrate. In addition, mechanical fasteners may be used, if appropriate. The installer shall determine the anchorage to be used, based upon its suitability and the substrate to which the signs are affixed.
STEP 3. Select an exit door, panic bar. Place the selected panic bar into its installed position on the actuating bar or touchpad. Ensure that the panic bar is straight and in the proper position on the substrate.
NOTE: ENSURE THAT THE PROPER POSITION OF THE PANIC BAR HAS BEEN DETERMINED. ONCE THE PANIC BAR IS PRESSED ONTO THE SUBSTRATE, REPOSITIONING OF THE PANIC BAR WILL BE EXTREMELY DIFFICULT.
ESI1531 08/07/12 Page 2
Figure
STEP 4. Using the anchorage determined to be suitable, attach the panic bar to the substrate, see Figure 2.
NOTE: LIMIT CONTROL OF AMBIENT ILLUMINATION LEVEL FOR
CHARGING BALCO, INC. PANIC BARS TO AUTHORIZED PERSONNEL ONLY. EXTERNAL UNFILTERED FLOURESCENT (OR EQUIVALENT) ILLUMINATION MUST BE PRESENT ON THE SIGNS AT ALL TIMES OF BUILDING OCCUPANCY.
WARNING: MINIMUM ILLUMINATION TO CHARGE THE
PANIC BARS SHALL BE NOT LESS THAN 11 LUX (1 FOOTCANDLE) FOR ONE (1) HOUR. INSUFFICIENT AMBIENT ILLUMINATION WILL RESULT IN FAILURE OF THE PANIC BARS TO CHARGE AND TO PHOTOLUMINESCE.
Page 3 © 2012, Balco, Inc.
ESI1531
08/07/12
Balco, Inc. Photoluminescent Egress SystemsBalco, Inc. Photoluminescent Egress Systems
Balco, Inc. Photoluminescent Egress Systems
Balco, Inc. Photoluminescent Egress SystemsBalco, Inc. Photoluminescent Egress Systems
Operation, Cleaning and MaintenanceOperation, Cleaning and Maintenance
Operation, Cleaning and Maintenance
Operation, Cleaning and MaintenanceOperation, Cleaning and Maintenance
Facility Name:
Facility Location:
Operations/Maintenance Manager:
1. Introduction
Balco, Inc. photoluminescent exit path marking systems are illuminated using either natural or artificial light sources. The performance of the photoluminescent components is dependant upon the light exposure, both intensity and duration. The type of lighting in a facility and its brightness will determine the required duration of exposure to adequately charge the photoluminescent components to achieve desired performance.
2. Operation
A. MINIMUM ACTIVATION SOURCE TYPE: Fluorescent Illumination.
B. MINIMUM ILLUMINANCE AT TARGET: 1 foot candle (11 lux).
C. MINIMUM ACTIVATION DURATION: 60 minutes.
Ensure that the source lighting is controlled by authorized personnel only. Maintain adequate light level and duration to properly activate photoluminescent components.
3. Cleaning
Establish a regular inspection schedule for the photoluminescent components and clean them as needed to prevent dirt, etc. from inhibiting the performance of the components. Balco, Inc. recommends inspection at least once every year or after any particularly heavy use. Perform inspections in accordance with applicable local and national code requirements.
Photoluminescent components attached to floor assemblies may be cleaned by mopping, using high-pressure water (but not steam cleaning) or wiping with a clean damp cotton cloth. Use mild detergents to clean the photoluminescent components, if necessary. Mild dish washing detergents or laundry detergents are recommended. Do not use highly alkaline detergents, those having a ph >8, or acidic cleaners, those having a ph <5. Do not use abrasive cleaners. Photoluminescent components on walls or other assemblies or components may be cleaned using clean water and a clean sponge or a clean cotton cloth. Rinse after applying detergent solution. Wipe with a clean cotton cloth to dry.
4. Maintenance
Inspect exit path markings, obstacle markings and photoluminescent stair nosings for damaged components and to ensure that photoluminescent components remain properly attached to their substrate and that no loosening of anchors or delamination of photoluminescent components has occurred.
Replace damaged components. Tighten any loose anchors. Hand tightening is sufficient. Repair delaminated photoluminescent components. Contact the factory for repair recommendations. Delaminated photoluminescent components in stair nosings can result in a trip hazard and should be repaired immediately.
ESI1531 08/07/12
Page 4
WARRANTY POLICY
Balco, Inc. warrants to its purchasers that all products sold by it will be free from manufacturing and material defects. Any defective product will be replaced or repaired free of any charge, provided a claim is brought to our attention, in writing, within the established warranty period following the date of shipment by us and provided our examination shows the product has failed under the terms of this warranty. The established warranty period for exterior joint cover systems (Duraflex by a Balco Certified Installer. The established warranty period for grids and mats is two (2) years. The established warranty period for all other Balco, Inc. products is one (1) year. Balco, Inc. will not be responsible for installation costs involved in such repair or replacement. Balco, Inc. shall have no obligation under this warranty if owner subjects materials to improper conditions (refer to Balco's installation instructions) This is in lieu of all other warranties, expressed or implied, and is the sole warranty extended by Balco, Inc. Our liability under this warranty is limited to repair or replacement and does not include any responsibility for consequential or other damage of any nature. It is further agreed and understood that the price stated for the seller's products is consideration for the limitation of seller's liability hereunder.
REGISTERED TRADEMARKS: BALCO, INC. PATENT NUMBERS: "VINYLINES" "SAF-T-GLO" 5,782,044; 5,829,216; 5,832,678; "METAFLEX" "SAF-TEN BEVEL" 6,014,848; 6,115,980; 6,581,347; "SENTRY" "DURAFLEX" 6,942,419; 6,955,017; 6,962,026; "ILLUMI-TREAD" "METABLOCK" 7,104,717; 7,856,781; 7,946,784; "MICHAEL RIZZA COMPANY" 8,079,190; 8,245,471; 8,464,485;
TM)
is five (5) years provided the systems are installed
8,607,519; 8,601,760; 8,646,235; Fire Resistant Joint Covers Patents Pending