Balboa Water Group Quiet-Flo Air Switch PushButton Blower Control User Manual

Quiet-FloTM Heated Blower with On/Off Air Button
Line Voltage
Wiring Diagram
Air Switch Button
(13070-XX - basic style*)
8’ Water
Detect Cable
(99742)
(Optional)
Air Switch Quiet-Flo Blower
with 600W Heater
(8141-6220)
Blower Operation
Air switch operation:
1st Press: High speed.• 2nd Press: Med. speed.• 3rd Press: Low speed.• 4th Press: Wave Mode.• 5th Press: Off.• In Wave Mode, the blower starts at high speed, • reduces to low speed, then rises to high speed. Then the cycle resumes.
Optional Heated Quite-Flo Blower
Any time the blower turns on, the heater turns on with it.•
Specifications / Overview
120 VAC 60 Hz.• 30 minute timer.• Purge cycle. • 4 Modes of operation: • Speed 3: High speed. Speed 2: Med. speed. Speed 1: Low speed. Wave Mode: Speed diminishes to low, then returns to high (within 12 seconds). Control board mounted in blower housing.• If the main power is interrupted while the timer is • running, the system will return to standby mode when power is restored.
Timers
When the system motor is activated, a 30 minute timer is automatically started. Once the 30 minutes run-time has expired, any equipment automatically turns off.
When the blower is turned off, it waits for 15 minutes and then runs a two-minute purge cycle. A purge cycle is designed to remove standing water from the air system, which helps maintain a sanitary bath system.
* See catalog or call for air switch button options.