Bakers Pride Oven GDCO-G User Manual

BAKERSBAKERS
PRIDEPRIDE
INSTALLATION AND OPERATING INSTRUCTIONS
Cyclone SERIES
GAS CONVECTION OVENS
Models: BCO-G and GDCO-G
INTENDED FOR OTHER THAN HOUSEHOLD USE. RETAIN THIS MANUAL FOR FUTURE
REFERENCE. OVEN MUST BE KEPT CLEAR OF COMBUSTIBLES AT ALL TIMES.
IMPORTANT INSTRUCTIONS: After the gas supply has been connected to your unit, it is
extremely important to check piping for possible leaks. To do this, use soap and water solution or solutions that are expressly made for this purpose. DO NOT USE matches, candles,
!
flames, or other sources of ignition since these methods are extremely dangerous. Instructions to be followed in the event you smell gas should be posted in a prominent location. Obtain these instructions from your local gas supplier.
!
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and
!
!
!
This equipment has been engineered to provide you with year round dependable service when used according to the instructions in this manual and standard commercial kitchen practices.
+1 (800) 431-2745 US & Canada +1 (914) 576-0200 Phone sales@bakerspride.com E-Mail +1 (914) 576-0605 Fax www.bakerspride.com Web Address
liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the Installation, Operating and Maintenance Instructions thoroughly before installing or servicing this equipment.
WARNING: Initial heating of oven may generate smoke or fumes and must be done in a well-ventilated area. Overexposure to smoke or fumes may cause nausea or dizziness.
BAKERS PRIDE OVEN CO., INC.
30 Pine Street
New Rochelle, NY 10801
!
!
!
1
INDEX
I. INSTALLATION INSTRUCTIONS Section Item Page
A Receiving 2 B Set Up / Mounting 2 C Installation with Casters (Optional) 3 D Location & Minimum Clearances 4 E Gas Connections 4 F Electrical Connection 5 G Flue Connection Ventilation 5 H Burner Operation 5 I System Check Rotary Control 5 J Programming Menus 6
II. OPERATING INSTRUCTIONS
A General Instructions 6 B Operation Sequence Rotary Control 6
Cook only Rotary Control 6
I. INSTALLATION INSTRUCTIONS
A. RECEIVING
Section Item Page
Timed Cooking Rotary Control 6 Cook and Hold Rotary Control 7 Optional Steam Injection Rotary Control 7
To Cool Down the Oven Quickly 7 C Cleaning 7 D Servicing 8
Stacking Instructions 9
Leg Assembly Instructions 9
Wiring Diagrams 10
Helpful Hints 12
Troubleshooting Chart 12
Parts List & Exploded View 13
Warranty 16
Read the notice on the outside carton regarding damage in transit. Damage discovered after opening the carton is “CONCEALED DAMAGE.” Carrier must be notified immediately to send an inspector and to furnish forms for claims against the carrier.
When the oven arrives, it should consist of:
! A crate or carton containing your new oven (two for a stacked unit). ! A carton containing four 31” legs with mounting hardware (set of four 6” legs is supplied for stacked
installations).
! A carton containing a Flue Adapter and a Draft Hood. Optional: for Direct Venting (Not available for
European Community Countries).
B. SET UP / MOUNTING:
NOTE:
This appliance must be installed by competent personnel in accordance with the rules in force.
In the U.K., Corgi registered installers (including the regions of British Gas) undertake to work to safe and satisfactory standards. This appliance must be installed in accordance with the current Gas Safety (Installation and Use) Regulations and the relevant Building Regulations/IEE Regulations. Detailed recommendations are contained in the British Standard Codes of Practice B.S. 6172, B.S. 5440: Part 2 and B.S. 6891.
In MASSACHUSETTS: All gas products must be installed by a “Massachusetts” licensed plumber or gas fitter. Ventilation hoods must be installed in accordance with NFPA-96, current edition, with interlocks as described in that standard.
Your oven will be packed sitting on its bottom. The skid may be left under the oven for convenience in further handling. Unpack carefully, avoiding damage to the Stainless Steel front and/or trim. If concealed damage is found, follow the instructions detailed in Section A (Receiving). Keep the area around the ovens free and clear of combustible materials. Do not store any materials on top of or under any oven. The provision for adequate air supply to your oven for ventilation and proper gas combustion is essential. As a minimum, observe the clearances detailed in Section D (Location). Provide adequate ventilation and make up air in accordance with local codes. Servicing your oven is done through the front control panel and right side access cover. Ensure that these areas are kept unobstructed for easy access.
2
For a single unit: Refer to Figure 4
(1) Tilt Oven over to left-hand side and attach two 31” legs on the right-hand side with three ½” bolts and
washers. Tighten firmly.
(2) Using proper lifting equipment, lift up the left-hand side and attach two 31” legs on the left-hand side
the same way.
For a stack of two ovens: Refer to Figure 3
(1) Remove flue from bottom oven prior to stacking. When top oven is properly positioned on bottom
oven, re-install the flue back on the bottom oven.
(2) Tilt lower unit over to the left-hand side and position two 6” legs on the right side (one for front and
one for back), secure in place by using 4 bolts (3/8”-16) per leg. Tighten firmly.
(3) Using proper lifting equipment, lift up the left side of the unit and attach the other two legs in the same
way.
(4) Using the lifting equipment, raise the top oven to proper height and slide on top of the bottom oven.
Line up sides and front and fasten to each other at the rear of the units by using a mounting bracket supplied in the stacking kit.
To assemble an open rack stand: Refer to Figure 1
(1) Loosen 12 bolts (attaching 31” legs) slightly. (2) Remove 4 inner bolts, 1 from each of the 4 legs, place top right angle and top left angle underneath
and tighten these 4 bolts. (3) Insert “Open Rack Shelf” and tighten into place with eight 3/8-16 screws, washers and nuts. (4) Position “Rack Supports” and tighten in place using 4 each of flat washers and 5/16-18 Hex Nuts.
Fit the Standard Flue Diverter supplied into the hole in the top of the oven for under ventilation hood installation and secure with screws. For direct venting, Flue Adapter and Draft Hood must be placed into the hole on top of the oven.
C. INSTALLATION WITH CASTERS (OPTIONAL): Refer to Figure 4
Four casters (two with wheel brakes) and the mounting hardware are packed and included in the shipment if ordered. Install casters with wheel brakes on the front of the unit. Installation of the unit should be made with a connector that complies with the latest edition of the Standard for Connectors for Movable Gas Appliances ANSI Z21.69 in the USA (CAN CSA-6.16 in Canada) and a quick-disconnect device that
complies with the latest edition of the standard for quick disconnect devices for use with gas fuel ANSI Z21.41 in the USA (CSA 6.9 in Canada). Adequate means must be provided to limit the movement of the appliance without depending on the connector and any quick disconnect device or its associated piping to limit appliance movement.
The restraint should be attached to the rear legs of the oven on which casters are mounted. If disconnect of the restraint is necessary, the restraint should be immediately reconnected after the appliance has been returned to its originally installed position.
Figure 1
Open Style Support Leg Not Supplied With Kit
1 2 3
4
OPEN RACK STAND ASSEMBLY INSTRUCTIONS: BCO-G & GDCO-G
Assembly Instruction
1. Place undershelf (6) between legs & secure with 1/4-20 UNC screws (4), flat washers (3) & locknuts (2). The holes for mounting the wire racks should be toward the front of the oven.
2. Place open rack supports (1) between legs & secure with 1/4-20 UNC screws (4), flat washers (3) & locknuts (2).
3. Slide wire rack supports (5) into position using the holes in the undershelf (6) as a guide.
Item P/N Description Quan
5
6
1 21818222 Support, Open Rack 2 2 770504 Lock Nut 1/4-20 12 3 8519600 Washer, Flat 1/4” 12 4 8208200 Screw, 1/4-20 x 3/4” 12 5 21816807 Support, Wire Rack 2 6 21818231 Undershelf, Gas Oven 1
3
!
D. LOCATION AND MINIMUM CLEARANCES:
Move the oven to its final location keeping the minimum clearance from the back of the oven to the wall. This clearance is necessary for safe operation and to provide proper air flow to the burner chamber.
MINIMUM CLEARANCES FROM COMBUSTIBLE AND NONCOMBUSTIBLE CONSTRUCTION
!
!
E. GAS CONNECTION:
The ovens should not be installed on the same gas supply line with space heaters, boilers or other gas equipment with high intermittent demand.
CAUTION: Do not store combustible items or materials on racks.
Under Ventilation Hood Direct Venting RIGHT WALL 1” 1” LEFT WALL 1” 3” REAR WALL 3” 3”
Suitable for installation on combustible floor when installed with legs or casters provided.
CAUTION: Do not set the oven with its back flat against the wall. It will not operate properly unless there is at least three inches breathing space behind the oven
!
!
!
The installation of the oven must conform to the latest local codes or National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Installation Code, CAN/CGA-B149.2.
The appliance must be isolated from the gas supply piping system by closing its manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.45kpa). The appliance and its shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ½ psig (3.45kpa).
Use a pipe joint compound that is resistant to the action of liquefied petroleum gases when making gas connections. For Propane gas, use at least ½” (13 mm) pipe or tubing with a 5/8” (16 mm) inside diameter.
For Natural gas, use ¾” (19 mm) pipe. The gas pressure regulator is part of the combination valve and is adjusted to yield a pressure of 3.5” water column (9 mbar) for Natural Gas. If the oven is ordered for use on Propane Gas or Butane, the pressure regulator in the combination valve is preset at the factory to yield a pressure of 10” water column (25 mbar).
NOTE: No external regulator is required.
Gas supply pressure in the European Community countries should be as below.
Gas Type Supply Pressure Gas Type Supply Pressure
G20 20 mbar G30 30 or 50 mbar depending on country G25 25 mbar G31 30, 37, or 50 mbar depending on country G20/25 20/25 mbar
A separate shut-off valve for each oven must be provided. It should be as close as possible to the place where the gas line goes into the oven. It must be located such that it is easily accessible. When stacking with another oven, two shut-off valves, one for each of the two ovens, must be provided.
After the Gas Supply has been connected, it is extremely important to check all the piping for leaks. Use a soap and water solution or a product expressly made for this purpose. Do not use matches, candles or a flame and so forth to check leaks since these methods are extremely dangerous.
4
F. ELECTRICAL CONNECTION:
The oven, when installed, must be electrically grounded in accordance with local codes and/or the latest
edition of the National Electrical Code ANSI/NFPA No. 70 in the USA (Canadian Electrical Code CSA
Standard C22.1, Part 1 in Canada).
In Europe, the appliance must be connected by an earthen cable to all other units in the complete
installation and, thence, to an independent earth connection in compliance with EN 60335-1 and/or local
codes.
The electric motor, all the related switches, interior lights, and the timer/buzzer are all connected through
the 6-foot (1829 mm) power supply cord located at the rear of the oven. The supply cord must be plugged
into a properly grounded, three-prong receptacle. DO NOT CUT OR REMOVE THE GROUNDING PRONG
FROM THE PLUG.
Normal factory connections are made for 120 volts A.C., 60 hz, Service in USA and Canada or 240 volts
A.C., 50 hz service in European community countries. Other voltages can be supplied upon request.
Electrical characteristics of this unit can be found on the rating plate located on the right side of the unit.
This unit is provided with a permanently lubricated electric motor. A wiring diagram may be found on the
back of the service panel on the right-hand side and in this manual.
G. FLUE CONNECTION VENTILATION:
Installation under ventilation hood (standard):
If the oven is not vented directly and is installed under a ventilation hood, the unit is ready to be installed as
is. Local inspectors and ventilation specialists should be consulted so that the design and the installation of
the hood conform to local/municipal codes. In the U.K., follow ventilation requirements as detailed in B.S.
5440.
Optional direct venting (not available for European community countries):
If direct venting, a flue adapter and a draft hood are required to be installed. They prevent the flue gases
leaving the oven to be affected by the air pressure changes on the outside of the flue stack extending out of
the building. The flue pipe from the draft hood must not run downwards at any point from the oven to the final
outlet. It should always slant slightly upwards. For best results, is should rise straight up. The venting
system shall be in accordance with the National Fuel Gas Code, ANSI Z223.1 / NFPA 54 and or the CSA
B149.1, Natural Gas and CSA B149.2, Propane Installation Codes, and local codes.
NOTE: DO NOT PUT A DAMPER IN THE FLUE AND DO NOT CONNECT A BLOWER DIRECTLY TO
THE FLUE.
If the flue runs directly to the free air outside the building, use a wind deflector or a UL listed vent cap at the
end of the pipe. Termination of the vent must be at least two feet above the highest part of the roof within ten
feet. REF: AGA CATALOG NO. XH0474.
H. BURNER OPERATION:
The oven burner flame should always have a blue appearance. This indicates a good mixture of air and gas.
When using LP gas, the flame will have a blue-yellow appearance. There may be intermittent yellow-orange
flame noticed. This is caused by dust particles burning in the flame.
I. SYSTEM CHECK- ROTARY CONTROL:
(1) Open the oven door. (2) Turn Selector Switch to “HI.” The indicator light near Selector Switch and oven light will
illuminate.
(3) Close the door. Oven lights will go off and fan will run. Make sure fan is rotating clockwise
looking from front.
5
Loading...
+ 11 hidden pages