GPE506 Gas Griddle Range, Electric Static Oven - 900mm.
GPE56 Gas Griddle Range, Electric Convection Oven - 900mm.
GPE508 Gas Griddle Range, Electric Static Oven - 1200mm.
GPE58 Gas Griddle Range, Electric Convection Oven - 1200mm.
Gas Conversion and Specifications ......................................................... 22
Conversion Procedure
Gas Specifications
Replacement Parts List ........................................................................... 26
Introduction
We are confident that you will be delighted with your BLUE SEAL Gas Griddle Range - Electric Oven and it
will become a most valued appliance in your commercial kitchen.
To ensure you receive the utmost benefit from your new Blue Seal appliance, there are two important
things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well
spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance,
contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your question.
CE Only:
These instructions are only valid if the country code appears on the appliance. If the code does not
appear on the appliance, refer to the supplier of this appliance to obtain the technical instructions for
adapting the appliance to the conditions for use in that country.
This appliance is for professional use and is only to be used by qualified
persons.
Only authorised service persons are to carry out installation, servicing or gas
conversion operations.
Components having adjustments protected (e.g. paint sealed) by the
manufacturer should not be adjusted by the user / operator.
DO NOT operate the appliance without the legs supplied fitted.
Caution
2
Specifications
Model Numbers Covered in this Specification
GPE506 Gas Griddle Range, Electric Static Oven - 900mm.
GPE56 Gas Griddle Range, Electric Convection Oven - 900mm.
GPE508 Gas Griddle Range, Electric Static Oven - 1200mm.
GPE58 Gas Griddle Range, Electric Convection Oven - 1200mm.
General
A commercial heavy duty, fully modular, gas fired griddle / electric oven range using a thermostatic
burner system on the griddle and fitted with 3 bar even heat aluminised steel burners with full pilot
and flame failure protection and piezo ignition to each burner.
All UK models and optional Non UK models are fitted with an overtemp device which isolates the gas
supply to burners should gas control system or thermostat malfunction, thus preventing overheating
of the griddle.
the
The griddle uses a 20mm thick griddle plate with
option of either ribbed or chromed mirror plate
options and is available in either 900 mm or 1200mm griddle size.
With a heavy duty, high efficiency electric static or convection oven options, fitted with a 900mm,
6.5 kW electric static oven and a 6.6 kW Convection Oven created for compact modular kitchens.
Both ovens are fitted with 4.5 kW bottom elements and 2.0 kW top element. The Convection Oven
is fitted with a 100W oven fan motor.
The appliance is built to facilitate easy cleaning and maintenance with all parts being front accessible
once appliance is installed.
* - Measure burner operating pressure at gas control valve outlet test point with one burner
operating at ‘High’ setting. Operating pressure is ex-factory set, through the appliance
regulator and not to be adjusted, apart from when converting between gases, if required.
(Refer to ‘Gas Conversion’ section for details).
(*) Measure burner operating pressure at at gas valve outlet test point with burner
operating at 'High Flame' setting.
NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
(**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Gas supply connection point is located 130mm from right hand side of appliance, 32mm from rear,
655mm from floor and is entered from beneath appliance. An optional underside connection is
available.