Bakbar GP513-B Installation Manual

INSTALLATION AND OPERATION MANUAL
GAS GRIDDLE
GP513 GP514 GP516 GP518
For use in GB & IE
229284-18
MANUFACTURED BY
Moffat Limited
Rolleston 7675 New Zealand
INTERNATIONAL CONTACTS
AUSTRALIA
Moffat Pty Limited Web: www.moffat.com.au E.Mail: vsales@moffat.com.au Main Office: (tel) +61 (03) 9518 3888
(fax) +61 (03) 9518 3838
Service: (tel): 1800 622 216 Spares: (tel): 1800 337 963 Customer Service: (tel): 1800 335 315 (fax): 1800 350 281
CANADA
Serve Canada Web: www.servecanada.com E.Mail: info@servecanada.com Sales: (tel): 800 551 8795 (Toll Free) Service: (tel): 800 263 1455 (Toll Free)
NEW ZEALAND
Moffat Limited Web: www.moffat.co.nz E.Mail: sales@moffat.co.nz Main Office: (tel): 0800 663328
UNITED KINGDOM
Blue Seal Web: www.blue-seal.co.uk E.Mail: sales@blue-seal.co.uk Sales: (tel): +44 121 327 5575
(fax): +44 121 327 9711 Spares: (tel): +44 121 322 6640 (fax): +44 121 327 9201 Service: (tel): +44 121 322 6644 (fax): +44 121 327 6257
UNITED STATES
Moffat Web: www.moffat.com Sales: (tel): 800 551 8795 (Toll Free)
(tel): +1 336 661 1556 (fax): +1 336 661 9546 Service: (tel): 800 858 4477 (Toll Free) (tel): +1 336 661 1556 (fax): +1 336 661 1660
REST OF WORLD
Moffat Limited Web: www.moffat.co.nz E.Mail: export@moffat.co.nz
The reproduction or copying of any part of this manual by any means whatsoever is strictly forbidden unless authorized p reviously in writing by the manufacturer.
In line with policy to continually develop and improve its products, Moffat Ltd. reserves the right to change the specifications and design without prior notice.
© Copyright Moffat Ltd. December 2014.
Contents
Blue Seal Gas Griddle
GP513 Gas Griddle, 450mm. GP514 Gas Griddle, 600mm. GP516 Gas Griddle, 900mm. GP518 Gas Griddle, 1200mm.
Introduction ............................................................................................. 2
Specifications ........................................................................................... 3
Model Numbers Covered in this Specification General Gas Supply Requirements Gas Connection
Dimensions ................................................................................................ 6
Installation .............................................................................................. 10
Installation Requirements Unpacking Location Clearances Assembly Gas Connection Commissioning
Operation ................................................................................................. 13
Operation Guide Description of Controls Lighting Pilot Burner Lighting Main Burner Turning ‘Off’ Main Burner Re-Setting Overtemp Device (All UK and Optional Non-UK Models)
Cleaning and Maintenance ...................................................................... 16
General After Each Use Daily Cleaning Weekly Cleaning
Fault Finding ............................................................................................ 19
Gas Conversion and Specifications ......................................................... 20
Conversion Procedure Gas Specifications
Replacement Parts List ........................................................................... 25
Introduction
We are confident that you will be delighted with your BLUE SEAL GAS GRIDDLE, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new BLUE SEAL GAS GRIDDLE, there are two important things you can do.
Firstly:
Please read the instruction book carefully and follow the directions given. The time taken will be well spent.
Secondly:
If you are unsure of any aspect of the installation, instructions or performance of your appliance, contact your BLUE SEAL dealer promptly. In many cases a phone call could answer your questi on.
CE Only:
These instructions are only valid if the country code appears on appliance. If code does not appear on appliance, refer to supplier of this appliance to obtain technical instructions for adapting appliance to conditions for use in that country.
Warning
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY
DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS APPLIANCE.
INSTRUCTIONS LOCATION. THIS INFORMATION SHALL BE OBTAINED BY CONSULTING THE LOCAL GAS SUPPLIER.
TO BE FOLLOWED IN THE EVENT THE USER SMELLS GAS ARE TO BE POSTED IN A PROMINENT
Warning
Warning
GREAT CARE MUST BE TAKEN BY THE OPERATOR TO USE THE EQUIPMENT SAFELY TO GUARD IT AGAINST RISK OF
FIRE.
 T  I
 DO NOT

HE APPLIANCE MUST NOT BE LEFT ON UNATTENDED.
T IS RECOMMENDED THAT A REGULAR INSPECTION IS MADE BY A COMPETENT SERVICE PERSON TO
ENSURE CORRECT AND SAFE OPERATION OF YOUR APPLIANCE IS MAINTAINED.
STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.

This appliance is for professional use and is only to be used by qualified persons.

Only authorised service persons are to carry out installation, servicing or gas conversion operations.

Components having adjustments protected (e.g. paint sealed) by the manufacturer should not be adjusted by the user / operator.

DO NOT operate the appliance without the legs supplied fitted.
Caution
2
Model Numbers Covered in this Specification
GP513 - B Gas Griddle 450mm wide Bench Model. GP513 - CB Gas Griddle 450mm wide with Cabinet Base. GP513 - LS Gas Griddle 450mm wide on Leg Stand.
GP514 - B Gas Griddle 600mm wide Bench Model. GP514 - CB Gas Griddle 600mm wide with Cabinet Base. GP514 - LS Gas Griddle 600mm wide on Leg Stand.
GP516 - B Gas Griddle 900mm wide Bench Model. GP516 - CB Gas Griddle 900mm wide with Cabinet Base. GP516 - LS Gas Griddle 900mm wide on Leg Stand. GP516 - RB Gas Griddle 900mm wide with Refrigerated Base.
GP518 - B Gas Griddle 1200mm wide Bench Model. GP518 - CB Gas Griddle 1200mm wide with Cabinet Base. GP518 - LS Gas Griddle 1200mm wide on Leg Stand. GP518 - RB Gas Griddle 1200mm wide with Refrigerated Base.
General
Specifications
A commercial heavy duty, fully modular, gas fired griddle using a thermostatic burner system and fitted with aluminised steel burners with full pilot and flame failure protection and piezo ignition. It uses a 20mm thick griddle plate with the option of either ribbed or chromed mirror plate options.
All UK Models and optional Non-UK models are fitted with an overtemp device which isolates the gas supply to the burners should the gas control system or thermostat malfunction, thus preventing overheating of the griddle.
The Griddle is constructed as a hob unit and is available in 4 options, on Leg Stand (-LS), Bench Mount (-B), Cabinet Base (-CB) or with Refrigerated Base (RB) models (RB Models available for GP516 and GP518 Models only).
3
Specifications
Gas Supply Requirements
- Australia
Input Rating (N.H.G.C.) Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.90 kPa 0.85 kPa 0.90 kPa 2.6 kPa 2.5 kPa 2.6 kPa Gas Connection ¾” BSP Male
GP513 GP514 GP516 GP518 GP513 GP514 GP516 GP518
40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr
Natural Gas
LP Gas (Propane)
- New Zealand Only:
Input Rating (N.H.G.C.) Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 0.90 kPa 0.85 kPa 0.90 kPa 2.6 kPa 2.5 kPa 2.6 kPa Gas Connection ¾” BSP Male
GP513 GP514 GP516 GP518 GP513 GP514 GP516 GP518
40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr
Natural Gas
LP Gas
- UK Only:
Category: II Flue Type: A
(20, 37).
2H3P
1.
Natural Gas (G20)
Propane (G31)
GP513 GP514 GP516 GP518
Heat Input (nett) 10.5 kW 13.3 kW 21 kW 28.5 kW 10.5 kW 13.3 kW 21 kW 28.5 kW Gas Rate (nett) 1.11 m3/hr 1.41 m3/hr 2.22 m3/hr 3.02 m3/hr 0.81 kg/hr 1.03 kg/hr 1.63 kg/hr 2.21 kg/hr Supply Pressure 20 mbar 37 mbar Burner Operating Pressure (*) 8.2 mbar 8.5 mbar 8.2 mbar 26 mbar Gas Connection
3
GP513 GP514 GP516 GP518
/4” BSP Male
* - Measure burner operating pressure at gas control valve outlet test point with burner operating at
‘High’ setting. Operating pressure is ex-factory set, through the appliance regulator and not to be adjusted, apart from when converting between gases, if required. (Refer to ‘Gas Conversion’ section for details).
For Refrigeration Cabinet Specifications refer to Refrigeration Cabinet Installation and Operation Manual supplied with appliance.
4
- All Other Markets
Specifications
Input Rating (N.H.G.C.) 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr Supply Pressure 1.13 - 3.40 kPa 0.75 - 1.50 kPa
Burner Operating Pressure (*) 0.90 kPa 0.85 kPa 0.90 kPa Gas Connection ¾” BSP Male
GP8450 GP8600 GP8900 GP8120 GP8450 GP8600 GP8900 GP8120
Natural Gas Town Gas (**)
0.45 kPa
GP513 GP514 GP516 GP518 GP513 GP514 GP516 GP518
Input Rating (N.H.G.C.) 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr 40 MJ/hr 53 MJ/hr 80 MJ/hr 108 MJ/hr Supply Pressure 2.75 - 4.50 kPa 2.75 - 4.50 kPa
Burner Operating Pressure (*) 2.6 kPa 2.5 kPa 2.6 kPa 2.6 kPa 2.5 kPa 2.6 kPa Gas Connection ¾” BSP Male
LP Gas (Propane) Butane
(*) NOTE:
 (*) Measure burner operating pressure at at gas valve outlet test point with burner
operating at 'High Flame' setting.
 NAT, LPG & Butane Only - Operating pressure is ex-factory set and is not to be adjusted,
unless when converting between gases, if required.
 (**) TOWN GAS Only - Adjust burner operating pressure using adjustable gas regulator
supplied.
 Refer to ‘Gas Conversion and Specifications' section in this manual for further details.
Gas Connection
Bench Models
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand side, 32mm from rear, 55mm from floor and is reached from rear of appliance. (Refer to ‘Dimensions’ section).
Connection is ¾" BSP male (For all other models).
All Other Models
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand side, 32mm from rear, 655mm from floor and is reached from beneath appliance. (Refer to ‘Dimensions’ section).
Connection is ¾" BSP male (For all other models).
5
Dimensions
Dimensions for Bench Models
GP513 - B
GP514 - B
= Rating Plate Location for
R
this option.
GP516 - B
GP518 - B
R
6
Dimensions
Dimensions for Cabinet Base Models
GP513 - CB
GP514 - CB
= Rating Plate Location for
R
this option.
GP516 - CB
GP518 - CB
R
7
Loading...