B-Air 2820 CFM Instruction Manual

Page 1
OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLE-SHOOTING
Instruction Manual
READ AND SAVE THESE INSTRUCTIONS
“Your company address here”
"Your company name here"
Page 2
Table Of Contents
Important Safety Instructions
Motor Specifications & Electrical Requirements
Grounding Instructions
Introduction
Product Features
Unpacking & Checking Of Contents
Operating Instructions
Maintenance
Cleaning
User Servicing Instructions
Lubrication
Storage & Transportation
Servicing
Limited Warranty
Parts List
Specifications
Troubleshooting
Warranty Registration
3
4
4
5
5
6
6
6
6
6
7
7
7
7
8
9
10
11
DATE: May 2018 FILENAME: “Your company name here”_MANUAL_FINAL
“Your company name here”
Page 3
IMPORTANT SAFETY INSTRUCTIONS
Your SAFETY is of utmost importance. Please stay alert, use your common sense and know how this air mover works at all times. While reading through this manual, please note these IMPORTANT safety signal words:
ATTENTION!
Read all safety rules carefully before attempting to operate the “Your com­pany name here”. Please retain this manual for future reference. NEVER operate this unit when flammable materials or vapors are present
_
electrical devices produce arcs or sparks which may cause a fire or an explosion. NEVER operate this unit unattended.
WARNING!
To reduce the risk of fire, electric shock or injury:
Observe the following warnings that appear on the motor housing of your “Your company name here”:
• Read and understand this manual and all labels on the Air Mover before operating the product.
• Use product only as described in this manual.
• To reduce the risk of electric shock, do not expose to rain, immerse in or use in standing water. Store indoors only.
• Use only with GFCI-protected outlets.
• When storing or transporting, do not stack air movers more than 5 units high.
• Do not use an extension cord with this air mover.
• Electrical appliances can ignite flammable vapors or dust. Do not use near combustible liquids, gases or dusts.
• Do not leave plugged into outlet when not in use or when servicing. Turn off before unplugging.
• To reduce the risk of stirring up and inhaling toxic vapors, do not use near toxic or hazardous materials.
• Never operate with safety grills removed.
• This unit has an automatically-operated protective device which may shut down the unit during operation. Unplug before servicing or cleaning.
• Do not use with solid state speed control device.
DANGER: indicates a hazardous situation, which WILL result in death or serious injury, if not avoided.
CAUTION:
• For dusty operations, wear dust mask.
• Do not move or carry air mover when it is operating
• Only operate on a level and stable surface to prevent it from falling and possibly causing injury or damage to unit.
WARNING!
To reduce the risk of electric shock, connect only to a GFCI protected outlet. Do not expose to water.
WARNING!
TO REDUCE THE RISK OF TIP-OVER DURING STORAGE OR TRANSPORT, STACK UP TO 5 UNITS HIGH ONLY.
CAUTION:
• This fan has an automatic motor shutoff device. It may restart without notice. To reduce the risk of injury, unplug before servicing.
• Do not use an extension cord with this fan.
WARNING: indicates a hazardous situation, which COULD result in death or serious injury, if not
avoided. CAUTION: indicates a hazardous situation, which COULD result in minor or moderate injury, if not avoided.
• Do not allow to be used as a toy. Close attention is necessary when used by or near children.
• Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
• Do not use with damaged cord, plug or other parts.
• Call customer service if your air mover is not working as it should, has missing parts, has been dropped, damaged, left outdoors or dropped into water.
• Do not pull or carry by cord, use cord as handle, close a door on cord, or pull cord around sharp edges or corners. Keep cord away from heated surfaces.
• Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
• Do not handle plug, switch or the air mover with wet hands.
• Do not put any object into air intake openings.
• Keep hair, loose clothing, fingers and all parts of the body away from openings and moving parts.
• Direct air discharge only at work area. Do not direct air at bystanders.
3
“Your company name here”
Page 4
Motor Specifications & Electrical Requirements
This “Your company name here” has a 2-speed, 115-volt, 60 Hz induction motor with a grounding conductor. Thermally protected, it will automatically shut down if overheated. The motor will re­start automatically once cooled, for as long as it is plugged into a power source.
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This air mover is equipped with an electric cord having an equipment grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.
Grounding Instructions
The “Your company name here” must be grounded. Should it malfunction or break down, grounding provides a path of least resistance for electric current and reduces the risk of elec­tric shock. This appliance is equipped with a cord that has an equipment-grounding conductor and a grounding plug. The plug must be inserted into a properly installed and grounded outlet, in accordance with all local codes and ordinances.
CORDS
• Use three-pronged adapters that are UL and CE approved and with Ground Fault Circuit Interrupter (G.F.C.I.).
• Do not use cords that show any kind of wear or damage.
• Cords are not covered by warranty.
WARNING! The Total amperage of the “Your company name here” plus all other devices plugged into the receptacle must not exceed 12 amps.
WARNING! Improper connection
of the equipment-grounding conductor can result in the risk of an electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance. If plug does not fit the outlet, have a proper outlet installed by a qualified electrician.
NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electrical Code.
4
“Your company name here”
Page 5
Introduction
Designed to move large volumes of air, the “Your company name here” can be used for drying wet carpet, furniture and floors and may also be used for ventilation.
Product Features
The “Your company name here” is perfect for use in commercial plumbing and janitorial projects.
While the “Your company name here” is lightweight, mobile and easy to transport, nothing is sacrificed in terms of air moving effectiveness. This is a unit that can be left on overnight for days until the job is completed and dry. Note: This unit cannot be left unattended for any amount of time.
As the ”Your company name here” draws only 4.5 amps at its highest setting, it is among the
BALANCED CARRYING HANDLE WITH CORD WRAP
PRIVATE LABEL AREA (OPTIONAL)
INTAKE GRILL
2 SPEED POWER SWITCH
EXHAUST OUTLET
OPERATIONAL
POSITIONS
5
“Your company name here”
Page 6
Unpacking & Checking Of Contents
Unpack your “Your company name here” carefully and inspect if all parts are intact. If any of the parts are missing or damaged, please call 800-242-1378.
Operating Instructions
This “Your company name here” requires NO ASSEMBLY. The “Your company name here” is packaged and ready to be put to work.
The “Your company name here” is intended to be used for drying carpet spills, drying surfaces such as bathroom floors, ventilating as well as circulating air.
1. Place the unit on the surface that needs to be dried.
2. Plug the unit into a grounded outlet .
3. Select the desired speed and position (0º, 45º or 90º].
Maintenance
Cleaning
User Servicing Instructions
WARNING: As with all electrical equipment, the unit must be disconnected
from power before servicing or cleaning.
WARNING: To reduce the risk of injury from the air mover accidentally starting, unplug power cord before cleaning. The outside of the unit may be cleaned with a damp cloth to remove any dust or residue.
WARNING: Be sure to disconnect power supply before attempting to service or remove any components. Do not attempt to service your air mover beyond what is described in the user manual. For all other servicing, follow instructions in the Warranty section.
1. Before each use, inspect the unit for damage, blocked inlets and exhaust and for foreign material buildup.
2. When the “Your company name here” is turned on, inspect the unit for excessive vibration. In the event of excessive vibration or if the fan wheel rubs against the rotomolded housing, immediately turn off the unit and have a certified technician inspect the unit.
6
“Your company name here”
45º Angle
Walls
90º Angle
Ceiling and Ventilation
Horizontal
Floors and Carpet
Page 7
Lubrication
NO LUBRICATION IS NECESSARY. The motor is equipped with lifetime lubricated bearings.
Storage & Transportation
1. Before storing your air mover, it should be cleaned.
2. Wrap the power cord around the carry handle on top of the unit to keep it untangled.
3. If you have more than one unit, store units by stacking. Do not stack more than 5 units high.
4. Never operate unit while on its side or while stacked.
5. THE “Your company name here” SHOULD BE STORED INDOORS.
Servicing
In order to receive service or replacement parts under warranty, you must: a. Call “Your company name here” for an RMA (Return Merchandise Authorization Number) b. Have your proof of purchase ready. Upon inspection, we will advise you of the repairs needed and the cost (if applicable). “Your company name here” will issue repair or replacement parts depending on warranty.
Limited Warranty
Warranty covers against defects in material and craftsmanship under normal intended use to original purchaser for a term of two (2) years from original date of purchase including parts, labor and one-way shipping. Housing is covered for a term of five (5) years from date of original purchase.
IMPORTANT!
Warranty does not cover signs of misuse, including (but not limited to) rough handling, abuse, tampering, improper voltage use and unauthorized maintenance or repairs.
CAUTION:
Do not operate this air mover while stacked on top of each other. Do not stack more than 5 units high.
7
“Your company name here”
Page 8
Parts List
1. Housing --------------------------
2. Motor --------------------------
3. Capacitor ------------------------
4. Fan ------------------------------
5. Air Intake Grill (M) ---------------
6. Switch Cover --------------------
7. Air Intake Grill (F)------------------
8. Air Exhaust Grill ------------------
9. Switch ---------------------------
10. Power Cord ----------------------
11. Rubber Feet ----------------------
12. Nut 5mm -------------------------
13. Screw 5x20mm ------------------
14. Screw 4x12mm ------------------
15. Screw 4x18mm ------------------
16. Screw 6x14mm ------------------
17. Screw 4x10mm ------------------
18. Washer 6mm --------------------
19. Screw (L) 6x20mm --------------
20. Screw 6x8mm ------------------
------------- X1
------------- X1
------------- X1
------------- X1
------------- X1
------------- X1
------------- X1
------------- X1
------------- X1
------------- X1
------------- X4
------------- X6
------------- X6
------------- X4
------------- X7
------------- X4
------------- X4
------------- X1
------------- X1
------------- X1
8
“Your company name here”
Page 9
SPECIFICATIONS
Motor 1/2 HP Amps L 2.8 / H 4.5 AMPS Speeds 2 / Positions 2: 0º, 45º, 90º Certification C-ETL-US Stackable 5 units Voltage 115V Cycle 60Hz Max Static Pressure 2.5” Weight Net 25 Lbs (28 Lbs with box) Size (LxWxH) 22.5” x 20” x 13” Wheel Speed (RPM) L 1520 / H 1700 Attached Cord 25’ (FT) 18 AWG Available Colors
9
“Your company name here”
Page 10
TROUBLESHOOTING
PROBLEM
Unit Not Running
Running But Making Loud, Grating Noise
Excessive Vibration
Blower Wheel Not Turning
Unit Runs But Shuts Off On Overload
POSSIBLE CAUSE
a) Switch is OFF b) No Power
c) Bad Outlet
d) Faulty Switch e) Faulty or Broken Motor Wire or Cord
a) Severe Jolting Causing Blower Wheel To Rub Against Housing
b) Severe Jolting Deformed Housing
a) Severe Jolting Caused Motor Shaft To Bend; Unit Is Out Of Balance b) Damaged Blower Wheel Blade c) Build Up Of Dirt On One Side Of Blower Wheel
a) Blower Wheel Jammed Against Housing
b) Broken/Loose Capacitor Wire; Failed Capacitor c) Damaged Housing Is Pressing On Blower Wheel
a) Failing Motor Bearings; Internal Electrical Fault In Motor b) Obstruction In Intake Grill/Exhaust Grill
SOLUTION
a) Turn Switch On b) Plug Unit In; Check Circuit Breaker c) Check Outlet/Change To Another Outlet d) Replace Switch* e) Use Volt/Amp Meter to Check On Continuity; Replace Faulty Motor Wire or Cord*
a) Remove And Replace Damaged Motor Or Motor Mounts*, If Needed b) Replace Blower Wheel Or Damaged Housing*
a) Remove And Replace Motor*
b) Replace Blower Wheel* c) Clean Blower Wheel Blades
a) Remove And Replace Damaged Motor Mounts*; Replace Blower Wheel, If Needed* b) Replace Capacitor Wire/ Motor, If Needed* c) Replace Housing/Unit, If Needed*
a) Replace Motor*
b) Remove Obstruction
*For these issues, please contact factory for further instruction/assistance.
10
“Your company name here”
Page 11
BY MAIL
Please complete, mail or fax your product registration card.
For multiple units, please list serial numbers on a separate sheet. This warranty card and your bill of sale must be presented for warranty service.
Company name
Contact name Title
Street address
City State Zip
Phone Fax
Email
Product serial number Date of purchase
Purchase from
Thank y f yr pchase.
B-AIR.COM
ONLINE
Please fill out and submit your warranty form at:
www.b-air.com/register
Warranty Registration
Warranty Registration
BY MAIL
“Your company name here”
Page 12
MAIL TO
SENDER ADDRESS HERE
AFFIX STAMP HERE
550 South Ayon Ave. Azusa, CA 91702 1-877-800-BAIR (2247) Fax: (626) 385-3307 Email: info@b-air.com Website: www.b-air.com
B-AIR.COM
“Your company address here”
“Your company address here”
“Your company name here”
Loading...