Badger Meter BIN User Manual

Ellipse® Pitot Tube Meter
BIN Meter
PTT-UM-00520-EN-02 (April 2014)
User Manual
Ellipse® Pitot Tube Meter, BIN Meter
CONTENTS
Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Location Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Flow Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Page ii April 2014
User Manual
1. The primary station can be installed in any position on vertical or horizontal lines. However for best result, on horizontal liquid lines where the risk of air/gas entrapment in the meter tubing is prevalent, install the element with the head under the horizontal centerline. For horizontal air or gas lines the head should be above the center line to prevent condensation.
2. Leave the protective caps in place to protect the valves against construction debris, dust, paint, and other contaminants. Close the valves after installation to prevent leakage on startup.
3. For pipes 2…6":
a. Pipes 2", 2-1/2", 3", 3-1/2" and 4", drill a 3/8" hole into pipe.
b. Pipes 5" and 6", drill a 7/16" hole.
c. Weld the coupling to the pipe in line with the hole.
d. Pass the probe through the packing gland and insert it into the pipe through the coupling. Tighten hex nut to
the coupling.
e. Push the probe until it touches the opposite side of the pipe and tighten hex nut of the packing gland.
6. For pipes 8…24" with double support:
a. Pipes measuring 8" and 10": Drill a 1/2" hole on side where reading will be taken and 13/32" on other side.
Pipe measuring 12": Drill a 5/8" hole on side where reading will be taken and 17/32" on other side. Pipe measuring 14" and 16": Drill a 7/8" hole on side where reading will be taken and 25/32" on other side. Pipe measuring 18", 20" and 24": Drill a 1-1/8" hole on side where reading will be taken and 1-1/16" on other side.
b. Weld a coupling to the pipe in line with the hole making sure it is in line with opposite hole.
c. Pass the probe through the packing gland and insert it into the pipe through the coupling. Tighten hex nut to
the coupling.
d. Push the probe through the pipe until it passes through opposite hole to ensure alignment.
e. Withdraw probe and weld other coupling to the pipe.
f. Push the probe through the packing gland until it enters other hole and is flush with outside wall of the pipe and
tighten hex nut of the packing gland.
g. Install the plug into the coupling.
Page 3 April 2014
Ellipse® Pitot Tube Meter, BIN Meter

LOCATION INSTRUCTIONS

NUMBER OF NOMINAL PIPE DIAMETERS
DISTANCES ARE EXPRESSED IN
THROTTLED VALVE OR REGULATOR
27
FLOW
Regulator or
Partially Closed
Valve
11
6
2
5
FLOW
Straightening
Vane
CHANGE IN PIPE SIZE
49
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
FLOW
10
4 6
6
4
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
2
FLOW
64
TWO ELBOWS IN DIFFERENT PLANES
4
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
FLOW
10
4
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
5
2
5
FLOW
Straightening Vane
424
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
4
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
TWO ELBOWS IN THE SAME PLANE
49
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
4
4
FLOW
9
5
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
2
FLOW
311
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
3
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
FLOW
Straightening Vane
FLOW
Straightening Vane
Straightening Vane
A SINGLE ELBOW
7
3 Preso
5
3
2
Straightening Vane
FLOW
2
FLOW
FLOW METERS
DEBITMETERS MEDIDOR DE FLUJO
3
Preso
FLOW METERS DEBITMETERS MEDIDOR DE FLUJO
Figure 1: Location instructions
Page 4 April 2014

FLOW CURVES

ANNULAR ROUND
User Manual
24"
20"
18"
14"
12" 16"
(For other sizes consult factory)
0 00
0
2
WATER 60° F SCH. 40 PIPE
2 3 4 5 6 78 9 1
0
0
0
0
2 3 4 5 6 78 9 1
0
0
0
1".75".5" 2" 2.5"1.5"1.25" 3" 4" 5" 6" 8" 10"
NOMINAL PIPE SIZE - SCHED. 40.
: BIN
100
90
80
70
60
50
40
30
20
O
2
10
9
8
7
6
5
4
3
2 3 4 5 6 7 8 9 1
0
0
USGPM
0
2
.3 .4 .5 .6 .7.8 .9 1 2 3 4 5 6 78 9 1
∆P – INCHES OF H
1
.9
.8
.7
.6
.5
.4
.3
.2
Page 5 April 2014
ANNULAR ROUND
Ellipse® Pitot Tube Meter, BIN Meter
24"
20"
18"
14"
12" 16"
0 0000
2
AIR, 100 PSIG, 70° F
2 3 4 5 6 78 9 1
0
0
0
0
0
1".75".5" 2" 2.5"1.5"1.25" 3" 4" 5" 6" 8" 10"
NOMINAL PIPE SIZE
100
: BIN
90
80
70
60
50
40
30
20
O
2
2 3 4 5 6 78 9 1
0
0
0
0
2 3 4 5 6 7 8 9 1
0
0
0
0
0
2 3 4 5 6 78 9 1
SCFM
10
9
8
7
6
5
4
3
2
3 4 5 6 78 9 1
∆P – INCHES OF H
1
.9
.8
.7
.6
.5
.4
Page 6 April 2014
.3
.2
0
24"
ANNULAR ROUND
20"
18"
14" 12" 16"
User Manual
2 3 4 5 6 78 9 1
0
0
0
AIR, 14.7 PSIA, 70° F
2 3 4 5 6 78 9 1
0
0
0
0
0
0
NOMINAL PIPE SIZE
: BIN
1".75".5" 2" 2.5"1.5"1.25" 3" 4" 5" 6" 8" 10"
100
90
80
70
60
50
40
30
20
O
2
10
9
8
7
6
5
4
3
2 3 4 5 6 7 8 9 1
0
0
0
SCFM
2 3 4 5 6 78 9 1
0
0
2
∆P – INCHES OF H
1
.9
.8
.7
.6
.5
.4
.3
.2
2 3 4 5 6 78 9 1
0
1
Page 7 April 2014
Control. Manage. Optimize.
PRESO is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0 Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503 Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411 Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836 China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 Legacy Document Number: 10-PTT-UM-00349
Loading...