Badger Meter AHL-GD - Hot Tap, High Pressure User Manual

Page 1
Ellipse® Pitot Tube Meter
SCH/WALL
MOD/β
DIA/ID
CAP
TAG
FLOW METERS
W/O
AHL-GD Dierential Pressure Flow Meter
PTT-UM-00327-EN-02 (April 2014)
User Manual
Page 2
Ellipse® Pitot Tube Meter, AHL-GD Dierential Pressure Flow Meter
CONTENTS
Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Pipe Orientation and Sensor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Installation Instructions, Single Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation Instructions, Double Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Location Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Flow Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Page ii April 2014
Page 3
INTRODUCTION
Impact Velocity Sensing Holes
The Preso patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement devices. This differential pressure flow meter is designed with a series of ports facing the upstream velocity pressures, as well as flow sensing ports strategically located ahead of the trailing edge flow separation.
The multi-ported, self-averaging flow element consists of an elliptical shape with two independent flow sensing chambers. The impact velocity sensing holes (high pressure) are located along the leading edge and the true static sensing holes (low pressure) are on the exterior probe side. Model AHL-GD comes with instrument shutoff valves with provisions to accept a transmitter or direct indicating meter.
SPECIFICATIONS
Applications Air, liquids and gases
Pipe Sizes 2…72 in. (50…1829 mm)
Pressure 800 psi (5515 kPa) maximum
Temperature 800° F (426° C) maximum
Accuracy ±0.75% of reading
Turndown Ratio 17:1 with no vacuum effect
T-type head, 316 SS 1/4 in. or 1/2 in. FNPT connection
CS 3000 lb. thread fitting, ASTM A105
316/316L SS Ellipse sensor
Instrument valves (2 per sensor), 1/4 in. or 1/2 in., CS
316 SS ID tag with wire
Standard Components
Reynolds Number
Resonance
150 lb. 316/316L SS sensor flange
CS packing chamber with molythane or graphite packing gland
CS packing chamber flange, 150 lb. with SS cap
316 SS isolation ball valve, NPT threaded
CS threaded nuts and bolts
CS nipples, schedule 40
Greater than 75,000 maintains most accurate flow measurements
Less than 75,000 consult factory for estimated results
Less than 0.8 but greater than 1.2. If greater than 0.8, use double support. System shutdown is required when the double support option is used. Select larger diameter ellipse to avoid double support.
Table 1: AHL-GD specifications
User Manual
True Static Sensing Holes
Figure 1: AHL-GD Ellipse pressure sensing holes
Page 3 April 2014
Page 4
Ellipse® Pitot Tube Meter, AHL-GD Dierential Pressure Flow Meter
with Proper Bleeding
Lock Nuts
FLOW
PIPE ORIENTATION AND SENSOR MOUNTING
H L
FLOW METERS W/O
MOD/β DIA/ID
SCH/WALL
CAP DP TAG
Field Weld
FLOW
FLOW
FLOW METERS W/O
MOD/β DIA/ID
SCH/WALL
CAP DP TAG
10° 10°
Air, Gas, or Liquid
FLOW
FLOW METERS W/O
MOD/β DIA/ID
SCH/WALL
CAP DP TAG
H L
Figure 2: Horizontal pipe installation
Field Weld
Liquid
MOD/β DIA/ID CAP DP TAG
FLOW METERS W/O
SCH/WALL
5° Max
10° 10°
.
or
Field Weld
Liquid, Air and Gas
Note: Illustration represents installation for downward ow.
Figure 3: Vertical pipe installation and sensor alignment
5° Max.
F L
W
O
FLOW METERS
W/O
SCH/WALL
MOD/β
DIA/ID
CAPDPTAG
Sensor Alignment
Note: Probe alignment applies to all horizontaland vertical installations.
Page 4 April 2014
Page 5
User Manual
Field Weld
INSTALLATION INSTRUCTIONS, SINGLE SUPPORT
1. Choose the proper location to install the AHL-GD Dierential Pressure Flow Meter using AGA/ASME standards (or equivalent). Refer to the location diagrams Figure 2, Figure 5 and Figure 6.
2. Grind the surface of the pipe where the AHL-GD Dierential Pressure Flow Meter is to be inserted to provide a clean area for welding.
3. Weld the supplied thread-o-let to the pipe using standard codes for your application (1/16 in. weld gap recommended). Take care to protect the threads during the welding process.
4. Install the close nipple by threading it into the weld connector. Next, install the supplied 3-piece isolating ball valve.
5. Mount the high pressure drilling machine onto the ball valve. Open the ball valve. Drill a hole through the pipe wall according to Table 2.
Model/Sensor Weld Connector Drill Bit
AHL-GD (7⁄8 in.) 1-1/4 in. 1-1�8 in.
AHL-GD (1-1/4 in.) 1-1/2 in. 1-3�8 in.
Table 2: Single support drill bit size
OTE:N There is no need for a drilling machine if it is not a hot tap installation or if the system is not pressurized.
6. Having drilled through the pipe, withdraw the drill bit through the isolating ball valve. Once the drill bit has been withdrawn, close the ball valve and dismantle the drilling machine. Ensure that there is no leakage at the valve and close nipple connections. The ball valve is to remain completely closed until step 9.
7. Install the cage nipple assembly and packing gland with the threaded rods assembly by threading it into the isolating ball valve. Align the arrow on the sensor head with the direction of ow. See Figure 4 and Figure 5.
8. Install the instrument valves (optional) at the pressure connections located on the AHL-GD Dierential Pressure Flow Meter sensor head. Ensure that the valves are fully closed before proceeding.
FLOW
H L
FLOW METERS W/O
MOD/β DIA/ID
SCH/WALL
CAP DP TAG
H L
FLOW METERS W/O
SCH/WALL
FLOW
Figure 4: Flow indication arrow
9. Open the isolating ball valve. Insert the AHL-GD Dierential Pressure Flow Meter sensor into the pipe until it reaches the opposite pipe wall. This should be done by turning the threaded insertion rods clockwise using a wrench.
10. Connect the instrument lines to the sensor head valves. In turn, connect these lines to a gage or transmitter.
Page 5 April 2014
Page 6
Ellipse® Pitot Tube Meter, AHL-GD Dierential Pressure Flow Meter
INSTALLATION INSTRUCTIONS, DOUBLE SUPPORT
1. Follow steps 1 through 6 in the single support section. At 180° from and on the same plane as the previously drilled hole, grind the surface of the pipe to provide a clean area for welding. Drill a hole and de-burr, especially on the inside of the pipe. The hole used for the double support should be sized according to Table 3.
Model/Sensor Weld Connector Drill Bit
AHL-GD (7⁄8 in.) 1/8 in. 3/8 in.
AHL-GD(1-1/4 in.) 1 in. 7⁄8 in.
Table 3: Double support drill bit size
2. Weld the double support thread-o-let making sure that it is centered with the drilled hole (1/16 in. weld gap recommended).
3. Install the AHL-GD Dierential Pressure Flow Meter sensor through the two holes. Make sure that the double support pin passes through the guide ring. See Figure 5.
Ellipse Sensor
Double Support Pin
Guide Ring
Figure 5: Double support installation
4. Align the arrow located on the sensor head in the direction of ow as shown in Figure 4.
5. Ensure that the AHL-GD Dierential Pressure Flow Meter is in the correct orientation and spans the inside of the pipe. Tighten the threaded insertion rods until the sensor reaches the other end of the pipe.
6. Install the plug into the end of the double support thread-o-let. Tighten the plug to prevent leakage.
Page 6 April 2014
Page 7
User Manual
MOD/ DIA/ID CAP DP TAG
MOD/ DIA/ID CAP DP TAG
MOD/β DIA/ID CAP DP TAG
MOD/ DIA/ID CAP DP TAG
MOD/β DIA/ID CAP DP TAG
MOD/β DIA/ID CAP DP TAG
MOD/ DIA/ID CAP DP TAG
MOD/ DIA/ID CAP DP TAG
MOD/ DIA/ID CAP DP TAG
MOD/β DIA/ID CAP DP TAG
LOCATION INSTRUCTIONS
Accuracy is affected by the piping configurations due to the disturbances of the flow profile. A fully developed symmetrical flow profile is achieved with the minimum upstream and downstream recommended lengths.
DISTANCES ARE EXPRESSED IN
NUMBER OF NOMINAL PIPE DIAMETERS
THROTTLED VALVE OR REGULATOR
27
FLOW
Regulator or Partially
Closed Valve
11
6 5
2
FLOW
H L
FLOW METERS W/O
β
SCH/WALL
H L
FLOW METERS W/O
β
SCH/WALL
4
4
Preso
Preso
TWO ELBOWS IN DIFFERENT PLANES
H L
FLOW METERS W/O
SCH/WALL
FLOW
10
FLOW
5
H L
FLOW METERS W/O
SCH/WALL
5
2
424
Preso
4
Preso
CHANGE IN PIPE SIZE TWO ELBOWS IN THE SAME PLANE
49
H L
FLOW METERS W/O
SCH/WALL
FLOW
4
10
64
H L
FLOW METERS W/O
β
SCH/WALL
2
FLOW
Straightening Vane
Straightening Vane
Preso
Preso
49
H L
FLOW METERS W/O
MOD/β DIA/ID
SCH/WALL
CAP DP TAG
FLOW
4
10
64
H L
FLOW METERS W/O
MOD/β DIA/ID
SCH/WALL
CAP DP TAG
2
FLOW
Straightening Vane
3
Preso
Preso
A SINGLE ELBOW
5
2
H L
FLOW METERS W/O
SCH/WALL
2
H L
FLOW METERS W/O
β
SCH/WALL
FLOW
37
Preso
3
Preso
4
2
Straightening Vane
11
9
FLOW
FLOW
β
5
β
Straightening Vane
H L
FLOW METERS W/O
SCH/WALL
H L
FLOW METERS W/O
SCH/WALL
3
Preso
3
Preso
FLOW
Straightening Vane
Figure 6: Location instructions
Page 7 April 2014
Page 8
FLOW CURVE
INCHES OF H
ANNULAR ELLIPS
10 in. CURVES ARE FOR SCHEDULE 40 PIPE
12 in. AND ABOVE ARE FOR SCHEDULE STANDARD PIPE
100000
12" 16" 20"
2" 2.5" 3.5"3" 4" 5" 6" 8" 10" 14" 18" 24" 30"
WATER 60 °F
2 3 4 5 6 7 8 9
10000
2 3 4 5 6 7 8 9
1000
2 3 4 5 6 7 8 9
USGPM
100
90
100
80
70
60
50
®
E
40
30
20
9
10
8
O
7
2
6
5
4
3
2
Figure 7: Pressure drops
1
.9
.8
.7
∆P –
.6
.5
.4
.3
.2
2 3 4 5 6 7 8 9
10
2 3 4 5 6 7 8 9
NOTE:
2…
1
Control. Manage. Optimize.
PRESO is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0 Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503 Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411 Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836 China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 Legacy Document Number: 10-PTT-UM-00301