Transmitters
Model 330 Programmable Relay Control
OVERVIEW
The Model 330 is a compact, programmable relay control
transmitter capable of converting the signal from a Badger Meter
flow sensor into a flow switch.
With an onboard microcontroller and digital circuitry, the Model
330 is programmed using a Windows® based computer program.
This eliminates the need to set dip switches or potentiometers and
produces precise, accurate and drift free control of the relay outputs.
In addition to accepting the Badger Meter square wave signal, the
Model 330 can accept other pulse and sine wave inputs.
The compact cast epoxy body measures 1.75" (44 mm) x 2.75"
(70mm) x 1.5" (38mm) and can easily be mounted to panels, DIN
rails or enclosures. With multiple inputs, ease of use and a variety of
enclosures, the Model 330 is a powerful, competitively priced relay
control device.
APPLICATIONS
Combined with a flow sensor the Model 330 can be used in a variety
of "Flow Switch" applications.
• Flow/no flow indicator
• High flow/low flow alarm monitor
• Booster pump control
• Multiple pump staging
• Leak control
Figure 1: Model 330 dimensions
FEATURES
Relay Output The Model 330 output is a pair of single pole
Selectable Alarm
Type
Programmable
Set & Release
Points
Programmable
Time Delays
Latch Feature The latch maintains the relays in the
Remote Reset Remote reset allows all the control
Alarm Status Using the Windows software, the actual
relays, one normally open and one normally
closed. Both relays act in unison to the
programmed parameters.
The Model 330 can be programmed as
a high flow alarm where the relays are
energized when the flow rate exceeds the
set point, and/or as a low flow alarm where
the reverse is true and the relays energize
when the flow rate falls below the set point.
The set point—the flow rate where the
relays are energized—is programmed
independently from the release point— the
flow rate where they are de-energized. This
adjustable deadband prevents relay chatter
and control cycling.
This feature provides a time delay between
crossing the set or release point and
energizing or de-energizing the relay. This
feature allows surges in the flow to dampen
out before the control circuit reacts.
energized state until manually reset, even
when the alarm condition has been satisfied.
parameters of the Model 330 to be reset by
an external signal.
flow rate status of relays and time delay
counters can be observed, providing great
diagnostic tools.
XMT-DS-01631-EN-02 (July 2015)
Product Data Sheet
Programmable Local Relay Control
330
W / DIN rail Mounting Clips04
Transmitters, Model 330 Programmable Relay Control
SPECIFICATIONS
Power
Power Supply Options 12…28V AC RMS, 200mA max 12…40V DC, 100mA max
Flow Sensor Input
All Sensors Excitation voltage 3 wire sensors: 9.1 V DC 500 Ω source impedance
Pulse Type Sensors
Signal Amplitude 2.5V DC threshold
Signal Limits Vin < 35V (DC or AC peak)
Frequency 0…10 kHz
Pull-up 2 kΩ
Sine Wave Sensors
Signal Amplitude 10 mV p-p threshold
Signal Limits Vin < 35V (DC or AC peak)
Frequency 0…10 kHz
Relay 1 form A, 1 form B
Contact Ratings 5A @ 30V DC 5A @ 125V AC 5A @ 250V AC
Time Delay 1…9999 second delay between flow point and relay actuation
Transient Suppression Designed to withstand a 5000 volt, 1/2 microsecond, 100 kHz ring wave
Sensor Calibration
Badger Meter Sensors Use K and Offset values provided in sensor owner's manual
Other Sensors Check with factory
Units of Measure
Flow Measurement Rate gpm, gph, I/sec, I/min, I/hr, ft3/sec, ft3/min, ft3/hr, m3/sec, m3/min, m3/hr
Programming Requires computer running Windows 7, XP or Vista
Operating Temperature –25…70°C –20…158°F
Storage Temperature –40…85°C –40…185°F
Weight 4.8 oz with headers installed
Accessories A301 programming kit with cable and software
EXAMPLE: 330 - xx
Figure 2: Model 330 ordering matrix
Figure 3: Optional enclosure (330-02 and 330-03)
Control. Manage. Optimize.
Data Industrial is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous
research, product improvements and enhancements, Badger Meter reserves the right to change product or system specications without notice, except to the extent an
outstanding contractual obligation exists. © 2015 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400
México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882
Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuen | Germany | +49-7025-9208-0
Europe, Middle East Branch Oce | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Oce #C209 | Dubai / UAE | +971-4-371 2503
Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411
Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01
Asia Pacic | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836
China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412
Legacy Document Number: DTB-015-01