Recordall® Turbo Series Meters
Models 160 (1-1/2"), 200 (2"), 450 (3"), 1000 (4"), 2000 (6"),
3500 (8"), 5500 (10"), 6200 (12"), 6600 (16") & 10000 (20")
RTS-UM-00380-EN-09 (January 2015)
User Manual

Recordall® Turbo Series Meters
RTS-UM-00380-EN-09Page ii January 2015

User Manual
CONTENTS
Scope of this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Related Literature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Unpacking and Inspection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Preinstallation Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installing the Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Maintenance Equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Periodic Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Shutdown Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Calibration Check and Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Accuracy Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Servicing Parts and Assemblies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Removing the Meter Head. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Removing the Local Register or Encoder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Removing the Measuring Element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Removing the Magnet Carrier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Removing the Straightening Vanes/Nose Cone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Removing the Calibration Mechanism. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Inspecting the Rotor and Bearings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Reinstalling the Turbo Meter Head Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Placing the Meter Back in Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
1-1/2" to 12" Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
16" and 20" Meters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
RTS-UM-00380-EN-09 Page iii January 2015

Recordall® Turbo Series Meters
RTS-UM-00380-EN-09Page iv January 2015

Scope of this Manual
SCOPE OF THIS MANUAL
This manual contains installation, operation and maintenance procedures for the Badger Meter® Recordall® Turbo Series
meters with magnetic drives. To ensure efficient operation of the meters, read and understand the instructions in this manual.
Retain the manual in a location where it is readily available.
PRODUCT INFORMATION
Product Description
The Recordall Turbo Series meters use proven design features such as thrust-compensated rotor geometry, direct drive
magnetic coupling, and dual outboard rotor bearings to achieve high accuracy over a broad flow range. Extended product
service life is achieved at higher levels of accuracy, in addition to lower meter maintenance costs. The Turbo meters are
available in 1-1/2", 2", 3", 4", 6", 8", 10", 12", 16" and 20" sizes.
Incorporating unitized construction with corrosion-resistant assemblies, the basic components of the Recordall Turbo Series
consist of the housing and the completely removable measuring element. The meter housing and cover plate are lead-free
bronze (1-1/2" to 10" sizes). The 12" to 20" meter housings are cast iron with a heat fused epoxy coating. The measuring
element is constructed of high-impact strength thermoplastics. Recordall Turbo Series meters are also equipped with an
integral calibration mechanism for in-line accuracy calibration.
In the operation of a turbo meter, water flows through the straightening vanes and a nose cone at the inlet side of the meter
so that the swirling effect of upstream piping is minimized. The water then strikes the rotor blades, causing the rotor to turn. A
downstream nose cone includes straightening vanes to limit the downstream effects of flow profile distortions. Optional NPT
test ports are provided for field performance testing.
Motion of the rotor is transferred by means of a worm drive to a vertical shaft driving a gear set, which transmits the rotation
to the meter's registration device. The direct drive magnetic coupling provides accurate flow registration during line surges,
and allows the permanently sealed register to be easily removed to facilitate in-line service.
Accessories
Meters and encoders are compatible with Badger Meter AMR/AMI meter reading systems and other approved reading
technologies. AMR/AMI solutions are available for all Recordall Turbo Series meters. All reading options can be removed from
the meter without disrupting water service. Badger Meter encoders provide years of reliable, accurate readings for a variety of
applications and are also available pre-wired to Badger Meter approved AMR/AMI solutions. See details at
www.badgermeter.com.
A strainer is recommended to provide optimal flow conditioning and protection for the measuring element. An integral
strainer is available as an option for 1-1/2" through 4" meter sizes. The stainless steel strainer is built into the inlet end
and includes a removable cover plate to permit easy access for routine cleaning. External strainers are available in sizes 2"
through 12".
Related Literature
• The Recordall Turbo Series Meters Product Data Sheet contains information on operating principle, meter construction,
materials, tolerances and specifications.
• The Recordall Turbo Series Meters Parts List contains illustrations of parts, part numbers, and part descriptions.
RTS-UM-00380-EN-09 Page 5 January 2015

Product Information
Safety Information
The installation of the Recordall Turbo Series meter must comply with all applicable federal, state, and local rules, regulations,
and codes.
Failure to read and follow these instructions can lead to misapplication or misuse of the meter, resulting in personal injury and
damage to equipment.
Unpacking and Inspection
To avoid damage in transit, Badger Meter Recordall Turbo Series meters are shipped to the customer in special shipping
containers. Upon receipt of shipment, be sure to follow these unpacking and inspection procedures:
OTE:N If damage to a shipping container is evident upon receipt of a meter, request that a representative of the carrier be
present when the meter is unpacked.
a. Carefully open the shipping container, following any instructions that may be marked on the container. Remove all
cushioning material surrounding the meter and carefully lift the meter from the container. Keep the container and
all packing material for possible use in reshipment or storage.
b. Visually inspect the meter and applicable accessory devices for any signs of damage such as scratches, loose or
broken parts or other physical damage that may have occurred during shipment.
OTE:N If damage is found, request an inspection by carrier’s agent within 48 hours of delivery. Then file a claim with the
carrier. A claim for equipment damaged in transit is the responsibility of the customer.
RTS-UM-00380-EN-09Page 6 January 2015