Life shouldn't stop when it's time to pump. That's why we've created a breast pump that gives
you more control over when and where you use it.
We know the pumping journey can feel lonely and isolating, and we’re here to make it just a
little bit easier. If you have any questions, please reach out at 844-744-PUMP (7867) or email us
at help@babyation.com.
We also invite you to join our online community at Babyation.com where we pull back the
curtain on parenthood with interviews, tips, and candid stories from the trenches.
Charge your breast pump ........................................................................................................................... 18
Breast shield assembly ................................................................................................................................ 19
Milk container placement and preparing to pump ..................................................................................... 19
Pairing your breast pump to Babyation’s feeding app ............................................................................... 22
Breast shield placement .............................................................................................................................. 24
Inserting the breast shield into the molded pad ........................................................................................ 24
Prepping for single pumping ....................................................................................................................... 25
Prepping for double pumping ..................................................................................................................... 25
To start pumping ......................................................................................................................................... 25
Adjusting speed and suction ....................................................................................................................... 27
Pausing the pump ....................................................................................................................................... 30
Stopping the pump ..................................................................................................................................... 31
At the end of the pumping session ............................................................................................................. 32
At the end of the pumping day ................................................................................................................... 35
The following symbols are used throughout the Babyation user manual, packaging, labeling, app, and on
the power adapter. Here’s a guide to refer to throughout your pumping journey. They’re like emojis for
real life.
6
Intended Use, Population, Contraindication
Intended use and population: The Babyation breast pump system is a powered suction device to be
used be lactating women in the hospital or home setting to express and collect milk from their breasts.
The Babyation breast pump system can be used by multiple users.
Contraindication: There are no known contraindications for the Babyation breast pump.
7
Important Safeguards
To avoid health risk and reduce risk of injury
Please read all instructions before using this product! We suggest doing this before a 3am pumping
session hits and it’s hard to see straight.
• While the breast pump system can be used by multiple users, each user must use her own
breast pump kit. Breast pump kits are personal care items intended for use by a single user and
should not be shared between users.
• Always unplug the system immediately after use, except when charging.
• Do not place or store product where it can fall or be pulled into a tub, sink, or other wet
location. Do not run water over breast pump enclosure. Do not use an electrical device that has
been exposed to water or other liquids.
• Do not use near flammable materials.
• Never operate an electrical device if it has a damaged cord or plug, is not working properly, or if
it has been dropped or damaged. If damage is found, immediately discontinue use and contact
Babyation at 844-744-PUMP (7867) or help@babyation.com.
• Use only the power adapter provided to power the unit and recharge the battery. If you need
another one, please purchase a Babyation power supply intended for use with this model.
• Loose tubing and cables may present a strangulation hazard. Keep all tubing and cables away
from children.
• If you are a mother who is infected with Hepatitis B, Hepatitis C, or Human Immunodeficiency
Virus (HIV), pumping breast milk will not reduce or remove the risk of transmitting the virus to
your baby through your breast milk.
• Do not use the pump while operating a motor vehicle.
• This device cannot be serviced or repaired. Do not repair yourself. Do not modify the device.
• Never use a damaged device. Inspect all components prior to use and replace damaged or worn
accessories.
• Use the breast pump only for its intended use as described in this manual.
• Replace tubing every 24 hours as described in this manual.
• Clean and sanitize breast shield and milk collection devices prior to first use. Do not clean or
sanitize your tubing.
• Clean breast shields after every use.
• Use only Babyation accessories with your Babyation breast pump system.
• The internal rechargeable battery is not replaceable. Do not attempt to service the battery.
• The Babyation device contains heat-generating components that could cause temperatures
above ambient. The device has been tested to ensure excessive heating does not occur.
8
• In order to disconnect the pump from external power, unplug the power adapter from the wall
socket. Ensure that the adapter remains accessible at all times in case it becomes necessary to
disconnect external power.
• While some discomfort may be felt when first using a breast pump, using a breast pump should
not cause pain.
• Wash hands thoroughly with soap and water before touching breast pump, kit, breasts, and
avoid touching the inside of the milk containers or lids.
• Use only drinking-quality tap or bottled water for cleaning your breast pump and parts.
• Ensure all parts are completely dry before use. Do not store wet or damp parts as mold may
develop.
• Do not try to express with suction that is too high, causing discomfort or pain. The pain, along
with potential breast and nipple trauma, may decrease milk output.
• Make sure tubing is not kinked or pinched while pumping.
• Ensure tube does not get pinched when closing lid.
• Using a breast pump on an aircraft is not recommended. The cabin pressure may affect the
breast pump’s performance.
• The breast pump can use Bluetooth® technology. Please follow your air carrier rules if using the
portable electronic pump when flying.
• For best battery life, try not to fully discharge the battery. If you are going to store the pump for
an extended period, be sure to fully charge the pump prior to storing. Continue to top off the
charge every several months.
• Plastic milk containers and parts become brittle when frozen and may break when dropped.
• The milk sensor will only work if the inside of the pump enclosure and outside of the bottle
exteriors are kept dry.
• Do not puncture the breast shield diaphragm. Keep the breast shield diaphragm away from
sharp objects.
• Breast shield parts should be completely dry before use.
9
• Discontinue pump use immediately and contact Babyation support if milk is seen in the suction
tube.
• Take care not to drop the pump. (But you knew that!)
• Do not store any other items in the pump lid besides the items that came with the device.
• Close enclosure lid when not in use to keep dust, lint, and dirt out of the system. Contamination
may reduce the effectiveness of the pump.
• Keep enclosure out of direct sunlight. This will make the display easier to read, will prevent
overheating of your milk, and will prolong the life of internal components.
• The breast shields should be replaced every 6 months.
• Keep the phone close to the breast pump to ensure the best Bluetooth® connectivity.
Connectivity issues may arise if the breast pump is used around other Bluetooth® devices.
• The expected operating life of this pump is approximately two years.
• The milk level sensor is accurate to a quarter of a fluid ounce.
10
Product Description
The Babyation breast pump system is a multi-user electric breast pump that you can use on either one
breast or both breasts simultaneously (single or double pumping). It has a built-in rechargeable battery
for increased portability and convenience, because we know these are important features for moms
everywhere.
The breast pump can also be controlled by the Babyation mobile app. The mobile app communicates
wirelessly through Bluetooth technology with the breast pump, allowing you to remotely control the
pump and and see real-time tracking of milk expression. There are additional controls on the breast
pump system that can be used by themselves or along with the mobile app controls, depending on your
preference. Personal data on the mobile app is secured, as is the wireless connection to the pump, to
prevent unauthorized use.
Components of Babyation breast pump system
1. Breast pump enclosure
a. Lid release button
b. LCD screen
c. Power button
d. Adjustment knob (hold down for selection button)
e. Ice pack
f. Breast shield storage
g. Milk container storage
h. Milk container storage (extra)
i. Tube storage fins
j. Cap storage
k. Single pumping cover (x2)
l. Enclosure connector pegs (x2)
m. Strap attachment pegs
n. Strap
o. Charging port (on back)
p. Filter
11
2. Breast shield (Applied Part - This part touches your breast)
a. Soft inner part (x2)
b. Outer shell (x2)
3. Tubing
a. Breast shield connector
b. Tubes
c. Enclosure connector
12
4. Milk container
a. Container (x4)
b. Pumping caps (x2)
c. Storage caps (x4)
5. Power adapter
13
6. Display icons
a. Bluetooth connectivity
b. Battery status
c. Amount of milk expressed by left breast
d. Amount of milk expressed by right breast
e. Pumping mode (stimulation or expression)
f. Level of speed
g. Level of suction
Cleaning Your Breast Pump System
Washing and sanitizing are two different things, and each plays a critical role in caring for your breast
pump system. Washing physically removes contamination, while sanitizing kills any organisms that may
be present.
Cleaning the breast shields, milk containers, and caps
14
When you unbox your breast pump system for the first time, you may be excited, confused, or likely a
bit of both. Before you fully embrace those feelings (which are totally normal), you should sanitize the
following items:
• Breast shield outer shell
• Breast shield soft inner part
• Pumping caps
• Milk containers
• Storage caps
DO NOT WASH, SANITIZE, OR CLEAN THE TUBING. THIS COULD RESULT IN PERMANENT PUMP DAMAGE.
To sanitize with boiling water:
1. Fill pot with enough water to cover all parts. Bring water to a boil.
2. Place parts in boiling water for 10 minutes.
15
3. Carefully remove from water with tongs or whatever utensil you have handy that keeps you
from getting burned. Place all parts on a clean towel or rack, and allow parts to air dry. Store
parts in a cool place when not in use. Do not store wet or damp parts. Breast shield parts must
be completely dry before use.
Separate and wash the breast shield outer shell and soft inner part, milk containers, pumping caps, and
storage caps immediately after use.
Washing in sink:
1. Rinse breast outer shell, breast shield soft inner part, milk containers, pumping caps, and
storage caps in cool water to remove milk residue.
16
2. Soak in warm soapy water for 5 minutes, and then gently scrub them and rinse.
3. Place all parts on a clean towel or rack, and allow parts to air dry. Store parts in a cool place
when not in use. Do not store wet or damp parts. Breast shield parts must be completely dry
before use.
Using dishwasher:
1. Rinse breast shield inner layer, breast shield outer layer, milk containers, pumping caps, and
storage caps in cool water to remove milk residue.
2. Place in top rack of your dishwasher.
3. Place all parts on a clean towel or rack, and allow parts to air dry. Store parts in a cool place
when not in use. Do not store wet or damp parts. Breast shield parts must be completely dry
before use.
Washing will help remove breast milk and prevent growth of bacteria. Store these items in a clean bag
or container until next use (Ziplocs or Tupperware work nicely). Take care not to damage parts of the
pump during cleaning.
Cleaning the breast pump enclosure and strap
Wipe down the unit with a damp cloth covered in soapy water or an alcohol-based disinfecting agent.
Wipe the remaining moisture off the unit with a dry cloth.
Loading...
+ 35 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.