LLSS66000000 LLEEVVEELL SSWWIITTCCHH
OOWWNNEERRSS MMAANNUUAAL
♦♦
IINNSSTTAALLLLAATTIIOONN
♦♦
CCAALLIIBBRRAATTIIOONN
♦♦
TTRROOUUBBLLEESSHHOOOOTTIINNGG
♦
WWAARRRRAANNTTY
Y
L
BABBITT
INTERNATIONAL, INC.
P.O. Box 70094
Houston, TX 77270
(713) 467-4438
TABLE OF CONTENTS
Page
1. Description ------------------------------------------------------- 1
A. General Description --------------------------------------- 1
B. Specifications ----------------------------------------------- 1
2. Theory of Operation/Ordering Information ---------------- 2
3. Installation ------------------------------------------------------------- 2
A. Inspection and Operation Check -------------------------- 2
B. Physical Installation -------------------------------------------- 2
C. Removing Electronics -------------------------------------------- 3
D. Typical Applications and Wiring Diagrams ----------------- 3
1) LS6000 Terminal Layout ----------------------------------- 3
2) Ladder Diagrams -------------------------------------------- 5
4. Calibration ------------------------------------------------------------- 6
A. Fail Safe Selection -------------------------------------------- 6
B. Sensitivity Calibration --------------------------------------- 6
5. Maintenance and Troubleshooting ------------------------------- 7
6. Warranty -------------------------------------------------------------- 8
1. DESCRIPTION
A. General Description
The LS6000 is a point level switch that detects the presence or absence of material in a bin, silo, tank or other
container. The basic unit is made up of a solid stainless steel probe attached to an explosion proof housing.
Inside the explosion proof housing are all calibration adjustments and sensing electronics.
The unit is calibrated in the absence of material and an internal relay changes state when material is detected.
B. Specifications
Electrical
Power:
(12 VDC, 24 VDC or 230 VAC optional)
Output: 2 Form C contacts, DPDT relay, 5 amp resistive
Fuse: on board, 250 mA
Fail Safe: Selectable high or low level
RF Frequency: Approximately 1.3 MHz
Environmental
Hazardous Area: Class I, Group D, Class II, Group E, F, G
Temperature: Probe: -30° F to 250° F
Electronics: -40° F to 185° F
Pressure: Probe: 1500 psi @ 75° F. Higher ranges available
on request.
Construction: Probe: All wetted parts, 316 SS, Delrin and Viton.
A Halar coating can be applied to the probe when
applicable.
Electronics: Housed in cast aluminum explosion
proof enclosure.
Specifications subject to change without notice.
LS6000 LEVEL SWITCH
115 VAC (±15%) 50/60 Hz. 2 watts, standard.
C. Ordering Information
1” NPT
1” NPT
½” DIA. 316 SS
6 1/8” 5 1/8”
INSULATOR
1 7/8”
4 ¾” 4”
MAX
10” Standard
Longer Lengths Available
FIGURE 6.1
1
LS6000 – 115VAC – S – 10*
Model
Supply Voltage
“S” – 316 Stainless Steel Probe
“H” – Halar Coated Probe
Probe length in inches
*This describes an LS6000, powered by a 115 VAC,
with a 316 SS probe, 10” long. The probe length is
measured from the end of the nipple to the tip of the
.
probe