Aztech MT400 User Manual

MT400
Aztech e-Nano Air Purier
USER MANUAL
PLEASE RETAIN THIS USER MANUAL FOR FUTURE USE.
SAFETY INSTRUCTIONS
Only use the authorized power adapter (DC 12V/1A) included in
Remove the power plug before doing any maintenance, cleaning,
or relocation of the appliance.
Do not use wet hands to operate the appliance, and insert or
remove its power plug to prevent electrical shocks. It is suggested
to thoroughly dry your hands before operating the Air Purier.
Do not obstruct the wind outlet/inlet of the appliance. Doing so will
reduce the Air Purier’s air cleaning efciency.
Do not sit or stand on the appliance.
When an operating irregularity occurs, please unplug the power
and send the appliance to the maintenance center for repair.
When unplugging the power plug, do not pull its cord. Hold the
power plug properly on its base to unplug it from the power outlet.
Position the Air Purier on a smooth and stable ground. Placing the
appliance on unstable surfaces such as softly cushioned carpets or
sofa, may make the appliance lose its balance.
Do not use the appliance near water resources or volatile ammable
items to prevent electrical shocks.
Do not position the appliance in hot places or in places commonly
exposed to multiple sources of heat such as refrigerators or
computers.
Should damages be found in the appliance, please do not use the
appliance and immediately send the appliance to the maintenance
center for repair.
Do not place any ammable materials near the appliance, or
position the Air Purier in an enclosed location where these materials
are present
When cleaning, use a soft, dry cloth to wipe the appliance gently,
or use a small brush to softly clean the wind inlets and outlets.
Do not clean the appliance with any type of acid-based solutions
to prevent damage and electric shock.
If not in use for long periods of time, ensure to keep the device in a
sealed and dry place.
3
PACKAGE CONTENTS
1) Air Purier
2) User Manual
3) Warranty Policy
3-STEP AIR PURIFIER FEATURES
Optional Step : Aromatherapy
Releases healing properties that
bring multiple health benets to
your body.
STEP 1 : e-Nano Filter
Collects and lters more than
99% of all air contaminants, odors, viruses, and smoke.
STEP 3 : Ultra Plasma Ion (UPI) Filter
Cleanses the ltered air by
eliminating the dust, odours, and airborne germs.
STEP 2 : Granular Activated Carbon
Quickly absorbs unpleasant odours and harmful chemicals present indoors.
BUTTON AND LED FUNCTIONS
Low Speed Mode
High Speed Mode
Carbon Filter
Replacement Indicator
UPI Filter Status Indicator
Power Button
1. Low Speed Mode. In GREEN when the Air Purier is in Low Speed
mode.
2. Carbon Filter Replacement Indicator. In FLASHING RED when the Carbon
Filter has reached its usage limit. Change the Carbon lter and press
the Power Button for 5 seconds to reset the indicator.
3. UPI Indicator. In BLUE whenever the Ultra Plasma Ion (UPI) is functioning.
4. Power Button. Shifts the speed mode to LOW or HIGH.
5. High Speed Mode. In GREEN when the Air Purier is in High Speed
mode.
4 - STEP OPERATION & USE
STEP 1: Position it PROPERLY
Place the Air Purier on a smooth and
stable ground. Ensure that there are no
ammable materials near the appliance,
and that the Air Inlets or outlets are not blocked by any objects.
STEP 2: Plug it to a Power Outlet
Plug the Air Purier to a 220V power
outlet.
STEP 3: Power it ON
Press the Power Button to turn ON the appliance. The UPI Status (Blue) and Low Speed Mode (Green) indicators would automatically turn ON.
STEP 4: Select a Speed Mode
Press the Power Button again to select and or shift between HIGH or LOW Speed modes.
*Air Inlets and Air Outlets must not be BLOCKED
*Low Speed Mode in green by default.
*High Speed Mode in green after shifting modes using the Power Button.
5
CARE and CLEANING
When to Replace the Filters
The Aztech MT400 Air Purier has an OPTIONAL aromatherapy feature
which enables you to use scented oils.
Hold the main body cover tightly and turn it in a counter clockwise manner to unlock it.
1.
USING THE AROMATHERAPY
STEP 1: Open the Diffuser Lid
Lift the Diffuser Lid open to access the aromatherapy pad.
STEP 3: Use Scented Oil
Use 3 to 5 drops of your choice of scented oil on the aromatherapy pad and close the Diffuser Lid.
3D Carbon Filter. The Carbon Filter Replacement Indicator would blink in
RED once it reaches 730 Hours (5 Months)
of use.
e-Nano Filter. Requires cleaning once
the lter turns black. It is recommended to be replaced with a new lter after 2
to 3 times of reusability.
Replacing the Filters
Separate the lter case from the
main body
2.
Hold the lter case rmly and
remove the Carbon Filter from the
lter case.
3.
Turn over the lter case and pull out the xture that holds the e­Nano lter.
4.
Reverse the lter case again and push out the e-Nano lter, with
your other hand supporting the e-
Nano lter’s dismantling.
5.
Once fully removed Clean the
lters as needed.
6.
After cleaning, reinstall the lters properly and close the lter case.
Ensure that the main cover has been properly placed and locked.
7.
7
TROUBLESHOOTING
Problem 1: My Air Purier is not working
Check if the Power is ON. Press the ON/OFF button to turn ON the Air
Purier
Check if the plug is loose or broken. Try reconnecting the power plug to the power outlet. Ensure that you are using the proper power adapter included in the package. Other power adapters might damage the device.
Problem 2: The Air Purier does not perform well
Your room might be too dry or is not properly ventilated. You may
slightly open the room’s door or window/s to increase indoor
humidity. Check if the air inlets do not have any blockage or is not blocked by any object. If these are blocked, change the location of the air
purier, or remove the external objects blocking the inlets.
Problem 3: I have just replaced the lters but the Carbon Filter Replacement Indicator is still blinking
After changing the carbon lter, press the Power Button for 5-6 seconds to reset the carbon lter timer.
Problem 4: The UPI Indicator is always blinking.
This is normal. Whenever the Air Purier is working, the UPI indicator is
also working at the same time.
Problem 5: I have an Air Purier problem not listed here
Please visit www.aztech.com/support. Feel free to call us or send us an email with the contact details provided on our site. Our Customer Service Representatives would willingly help you with your problem.
Copyright © 2014 Aztech Technologies Pte Ltd (CRN:199800635M ). All rights reserved.