![](/html/e4/e4e5/e4e5cc86e5cdba5b90be8e684e3a4d4c82f096e78befee3eb6d81b2e561b4a93/bg1.png)
COMPLETE LCD SOLUTIONS
Page 1 of 14
SPECIFICATIONS FOR
LIQUID CRYSTAL DISPLAY
PART NUMBER: AGM6424B
DATE: JANUARY 21, 2003
AZ DISPLAYS, INC.
![](/html/e4/e4e5/e4e5cc86e5cdba5b90be8e684e3a4d4c82f096e78befee3eb6d81b2e561b4a93/bg2.png)
1. LCD Module
1.1 Main Data
No. Item Contents Unit
(1) Module size 173.0(W) x 73.0(H) x 7.0(D) mm
(2) Viewing area 156.0 (W) x 60.0 (H) mm
(3) Dot Number 640 x 3 (R.G.B) (W) x 240 (H) dots
(4) Dot Size 0.065(W) x 0.225(H) mm
(5) Dot pitch 0.08(W) x 0.24(H) mm
(6) LCD type Color-STN (Negative type)
-
(7) Contrast ratio (30) -
(8) Duty 1/244 -
(9) Viewing direction 6 o clock -
(10) Operating temperature +0 ~ +50 C
(11) Storage temperature -20 ~ +70 C
(12) Backlight Cold Cathode Fluorescent Lamp (CCFL) x 1 pcs
(13) Power Supply Voltage 3.3V -
(14) Weight (120) g
AGM6424B
Page 2 of 14
![](/html/e4/e4e5/e4e5cc86e5cdba5b90be8e684e3a4d4c82f096e78befee3eb6d81b2e561b4a93/bg3.png)
1.2 Interface Pin Connection
CN1 : 52893-2090(MOLEX) / Suitable FPC : Pitch 0.5mm, width 10.5mm
Pin No. Signal Pin Function
1 FLM Scan start-up signal
2
SS
GND
3 CL1 Input data latch signal
4
SS
GND
5 CL2 Data shift clock
6
SS
GND
7 DISP Display control signal H:ON , L:OFF
8
DD
Logic supply voltage
9
CON
Contrast adjust voltage
10
SS
GND
11 D0 Display data
12 D1 Display data
13 D2 Display data
14 D3 Display data
15
SS
GND
16 D4 Display data
17 D5 Display data
18 D6 Display data
19 D7 Display data
20
SS
GND
CN2 : BHSR-02VS-1 (JST) / Suitable
connector : SM02B-BHSS-1-TB (JST)
Pin No. Signal Pin Function
1 H.V Power supply voltage for CFL
2 GND CFL GND
AGM6424B
Page 3 of 14
V
V
V
V
V
V
V
V
![](/html/e4/e4e5/e4e5cc86e5cdba5b90be8e684e3a4d4c82f096e78befee3eb6d81b2e561b4a93/bg5.png)
3. Maximum Ratings
3.1 Electrical Absolute Maximum Ratings. (VSS=0V)
Item Symbol Min. Max. Unit
Power supply for Logic VDD-VSS -0.3 7.0 V
Input voltage (Note 1) V
I
-0.3 V
DD
+0.3 V
Note 1. FLM,CL1,CL2,DISP,D0~D7.
Note 2. Ta=25 C
Note 3. Please be sure users are grounded when handling the LCD module.
3.2 Environmental Absolute Maximum Ratings
Storage Operating
Item
MIN. MAX. MIN. MAX.
Remark
Ambient Temperature -20 C 70 C 0 C 50 C Note1,2,3
Humidity Note 4 Note 4 No Condensation
Note 1. Ta at -20 C --------< 48hours, at 70 C --------< 120 hours.
Note 2. Background color changes slightly depending on ambient temperature.
This phenomenon is reversible.
Note 3. When LCM is operated at 0 C, the lifetime of the CFL will be reduced.
The response time at 0 C will increase.
Note 4. Ta<=50 C : 85%RH MAX.
Ta> 50 C : Absolute humidity must be lower than the humidity of 85% RH at 50 C.
AGM6424B
Page 5 of 14