Ayrton MODULED 150 User Manual

Page 1
MODULED 150 - MANUAL UK1
www.ayrton.eu
User’s manual
pjg g g g
ENGLISH
Page 2
2
SUMMARY
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
SUMMARY
01. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
02. SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . 3
03. USE AND APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . 4
04. DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
05. DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
06. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
01. YOKE ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
02. FLANK SIDES ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . 6
03. OPTIONAL FILTER HOLDER SETUP . . . . . . . . . . . . . . . . . . . 6
04. INTERNAL FILTER HOLDER SETUP . . . . . . . . . . . . . . . . . . 7
05. PROJECTOR RIGGING . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
06. PROJECTOR CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . 8
07. DMX 512 CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . 10
07. PROTOCOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
01. MODULED 150 RGB DMX PROTOCOL . . . . . . . . . . . . . . . 11
02. MODULED 150 AWW DMX PROTOCOL . . . . . . . . . . . . . . . 11
03. MODULED 150 AWB DMX PROTOCOL . . . . . . . . . . . . . . . 12
08. CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
01. INFRA-RED KEYS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
02. DISPLAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
03. STAND BY MODE : MODULED 150 UNLOCKING . . . . . . . 13
09. MODULED 150 MENU . . . . . . . . . . . . . . . . . . . . . . . . . . 14
01. MODULED 150 MENU CHART . . . . . . . . . . . . . . . . . . . . . 14
02. DMX ADRESS MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
03. DMX MODE MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
04. OPTIONS MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
01. DIMMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
02. DEFAULT VALUES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
03. BRIGHTNESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
05. INFORMATION MENU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
01. SERIAL NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
02. SOFTWARE VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
03. TEMPERATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
04. SCHEDULE COUNTER . . . . . . . . . . . . . . . . . . . . . . . . . . 16
05. LEDS COLOURS PRE-SET . . . . . . . . . . . . . . . . . . . . . . . . 17
10. SETTING THE MODULED 150 VIA COUGAR 2 . . . . . . 17
11.TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . 17
01. OPTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
02. SOURCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
03. COLOURS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
04. FROST, DIFFUSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
05. DIMMER, STROBE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
06. SOFTWARE FACILITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
07. CONTROL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
08. POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
09. COOLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
10. CONSTRUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
11. INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
12. UTILIZATION SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
13. CONFORMITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
14. WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
15. PRODUCTS CODES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
16. ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
12. MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
01. CLEANING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
02. SUPERVISION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
13. SOFTWARE UPDATE . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
14. WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Page 3
3
01. INTRODUCTION
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
01. INTRODUCTION
Thank you for choosing AYRTON’s products and for your trust in MODULED 150.
Your MODULED 150 needs other AYRTON accessories for use. These accessories, not supplied with your MODULED 150, are :
Connection box EASYBOX HD
AYRTON Multifunction hybrid connection cables (these
cables merge power and command DMX signals)
Other accessories needed according to application
requirements (Filter holders and diffusion filters,…)
WARNING !
This product is not suitable for home use.
You are in possession of a professional product with many applications. Before installation, make sure your MODULED 150 has not suffered damage during transport. If it is damaged in anyway, do not use this product and contact your AYRTON dealer immediately.
If you would like additional information, or to get the latest software update for your MODULED 150, please visit our website www.ayrton.eu.
For your own safety and that of others, please read this manual before the first operation of this device.
Any person involved in the installation, use or maintenance of your MODULED 150 must:
Be qualified for this type of operation
Strictly respect the instructions mentioned in this manual
Please take the time to fully and carefully read the manual before installing and using your MODULED 150, in order to gain a thorough knowledge of the conditions of use, safety instructions and all information concerning this product.
Once you have become familiar with the Moduled 150, we recommend you keep a copy of these instructions for reference.
All information contained in this manual are subject to change without notice.
AYRTON reserves the right to change and improve all the products in its range over time, without having to incorporate the changes in the products previously sold.
02. SAFETY INSTRUCTIONS
Before installing and using your MODULED 150, carefully read the instructions and safety precautions of use listed below.
WARNING!
RISK OF ELECTRIC SHOCK
Be careful when handling, this device
requires a high voltage which may cause
a risk of electric shock.
Your MODULED 150 left our factory in perfect working order. However, if you notice a defect, you should immediately contact your AYRTON dealer before use.
The manufacturer cannot be held liable for damages caused by failure to follow safety instructions, installation or assembly, mentioned in this manual, or any change in your MODULED 150.
Failure to comply with the safety instructions, installation or assembly and editing your MODULED 150 lead to the nullification of the warranty.
Check that the Mains voltage does not exceed the maximum allowable voltage.
Make sure your electric installation is up to standard rules.
For reliable and safe operation, your MODULED 150 requires the use of a power cable hybrid type, specifically designed and marketed by AYRTON. This cable, not included with the product, is available as an option in a wide variety of lengths. You should use only the power cables original designed and manufactured by AYRTON with your MODULED 150.
Always check the cables for physical damage such as gashes, splices or breakages.
Handle these power cables with extreme caution if they are connected to the mains.
Always remember to check your MODULED 150 and the power cables you use together before each use.
Your MODULED 150 complies with the safety standards of Class 1. Earth to the unit is supplied through the multifunction cable and EASYBOX HD, The EASYBOX HD must always be connected to earth.
The installation and electrical connections must be performed by a certified installer. AYRTON declines liability for any installation of your MODULED 150 by an unqualified person.
Page 4
WARNING !
Never connect or disconnect the power hybrid cable
from your MODULED 150 when power is connected.
This may damage the internal electronics
of your MODULED 150 and require repair.
Always cut power to your MODULED 150 by removing
the power of connection box EASYBOX
HD before connection or disconnection
of your MODULED 150.
To disconnect your MODULED 150, do not pull on the power cable! Unscrew the blue ring connector of the power cable (not supplied) until its full disengagement, and then gently pull the connector to unplug the cable.
Do not connect or disconnect the power cable from your MODULED 150 with wet hands.
Be careful to never leave objects or liquid inside your MODULED 150 during operations set up filters dissemination within the device.
On first use, smells may come from your MODULED 150. It is a normal phenomenon that will fade after a few minutes of use.
03. USE AND APPLICATIONS
Your MODULED 150 is a fixture with multiple LED light sources (Light Emitting Diode) for professional use (Show Events, Clubs, Architectural lighting, Exhibitions, Museums, TV stages, Theatres…).
It was designed to be used indoors or outdoors. Its index of protection is IP66. Your MODULED 150 may in no case be partly or fully submerged, even temporarily.
Condensation may form on your MODULED 150 in the following cases:
Immediately after having lit the device. In a steamed or very wet room or environment.When the MODULED 150 is brought from a cold
environment in a warm environment. In these cases, you must wait for the fixture to be returned to the ambient temperature of the room where it is placed before use.
If you open your MODULED 150 (for an introduction of a diffusion filter, for example), moisture from the air trapped in the device can cause the formation of condensation inside the fixture the next time it is used. This condensation will quickly fade as the MODULED 150 has an exhaust system humidity and pressure compensation valve fitted.
Do not shake your MODULED 150 at its setup or its manipulation.
Never move your MODULED 150 by the power cable. Use the handle of the fixture’s body.
The choice of installation/location of your MODULED 150 is very important:
You must not expose it to a heat source.You should not install it near flammable materials.You must ensure that dust and debris will not form on the
housing and remain in the cooling fins of the body of MODULED 150, which may alter its optimal cooling and impair its operation.
The MODULED 150 must be installed away from the public
and all persons who are not empowered to maintain on the fixture.
You must comply with a minimum distance of 0.5 m between the surface output of the light beam and object to be illuminated.
By the nature of its principle of cooling (natural convection), you should never impede free air to circulate around the body of the fixture. You must provide a minimum clearance of 0.5 m around your MODULED 150 to promote cooling.
The installation of a MODULED 150 in a pit of soil or other confined enclosure can be done only under certain conditions. The MODULED 150 ensures its natural convection cooling, it is appropriate in this case installation to establish a forced ventilation system suitable for the air to circulate around the device. The air must be constantly renewed, it can not be operated in a closed circuit. Failure to comply with these constraints could result in the destruction or premature wear out of MODULED 150, in which AYRTON could not be held responsible. Please consult your AYRTON dealer for more information on this type of facility.
No load can be applied on MODULED 150. It should never been installed into a recess. where objects may be placed on it or allow the passage of a person or vehicle or other object on the MODULED 150.
Never project or drop your MODULED 150 upon hard surfaces and all objects made of glass or porcelain (bottles, crockery, marbles,…). The MODULED 150 consists of aluminium smelting and glass, which makes it highly resistant but not unbreakable. Falling objects made of hard materials such as steel or glass on the device may cause breakage of the glass or body thereof. AYRTON can not be held responsible for the breakage of the glass or the body of the fixture, which is excluded from the guarantee.
Warning: The temperature of the glass surface of your MODULED 150 is likely to reach 45°C, depending on its use.
The body temperature of the aluminium device is however expected to reach 70°C. Verify that the application you intended to install your MODULED 150 is compatible with these informations.
4
03. USE AND APPLICATIONS
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 5
Make sure the support on which you hang your MODULED 150 can safely accept the weight of this device,
6.4 Kg, including all the safety factors required.
You must secure your MODULED 150 grip to the load-bearing structure with a safety bond or strap. The safety bond must be attached to the ring of security present on the MODULED 150, dedicated to that use. This ring of security is not provided for the suspension of your MODULED 150.
You should not use your MODULED 150 before being familiar with these recommendations, and you should not allow intervention on it by unqualified persons.
If your MODULED 150 should not be used for a long period, you must disconnect the power supply. To transport your MODULED 150, it is strongly recommended to use its full original packaging, including 2 thermoformed shell protection.
Your MODULED 150 should not be discarded in the trash, it must be recycled, as the logo on the label affixed to the fixture. Please refer to the laws in force in your country regarding the recycling of electronic devices.
04 - DIMENSIONS
FRONT VIEW:
VIEW FROM ABOVE (WITHOUT THE FLANKS SIDE):
VIEW FROM ABOVE (WITH THE FLANKS SIDE):
note : all dimension are in millimeters.
SIDE VIEW :
05 – DESCRIPTION
12. Fixture body
13. Power supply unit cover
14. Fixture Identification sticker bearing the serial number and model
15. 7-Core-HD-Multifonction
input Connector
17. 7-Core-HD-Multifonction output Connector
18. Tapped holes for fastening flanges Sides or safety ring
19. Suspension yoke
20. Yoke tightening wheel
1. LED Matrix n°1
2. LED Matrix n°2
3. LED Matrix n°3
4. Tempered glass window
5. Aluminium front
6. Front window fixing screws
7. «MODE » Key
8. «UP » Key
9. «DOWN » Key
10. «ENTER » Key
11. Display
5
04 - DIMENSIONS
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
207.5
1
91.5
59.8
150
61
95.7
27
Ø
35
141.7
2
11
4
3
181.4
476
267.8
207.5
150
75238
3 HOLES Ø10.5
2 HOLES M10
92
468
150
6
7
8
10
9
5
18
18
16
76.5
20
15
19
14
12
13
20
16
18
18
17
Page 6
06.INSTALLATION
01. YOKE ASSEMBLY
Your MODULED 150 comes partially disassembled in its original packaging. If you want to use the suspension yoke provided with the device, you need to mount the various elements as shown on the following chart :
You must first install on the body of the fixture, on either side of the PSU cover, 2 brackets with the CHC M5 screws 2 x 16mm provided. Next, place the yoke between media lyre and insert between these parts washers notched 27mm diameter (one on each side). Finally, screw on each side of the yoke wheel clamping head M8 x 20mm plastic, passing it through the media yoke and the puck serrated. Check the correct setting of the various elements of this package.
02. FLANK SIDES ASSEMBLY
The MODULED 150 also comes with 2 lateral sides, which allow other types of MODULED 150 to be connected together.
These flanks allow to fix the fixture from the rear on an adjusted baking, using the M10 fixing inserts located in these flanks, for the realization of “CLUSTERS” MODULED 150 to a chassis for example . In this case, the sides are to be mounted directly onto the body of MODULED 150, using the 4 x 22mm screw M5 provided (2 per side), as shown in the following diagram :
These sides can also be used to ensure solidarity among several MODULED 150 online. In this case the flanks must be solidified between 2 MODULED 150 before assembling on MODULED 150.
The assembly of the 2 sides made within the timeline of the following diagram :
First the 4 pillars should be screwed (16mm) to the flanks, then screw the 8 screws TFHC M5 x 10mm (4 per side) to ensure the flanks have solidarity between them. It will remain only to screw the sides on each MODULED 150 with the screws CHC M5 x 22mm provided. This produces a linear projector including several MODULED 150, as shown in the following diagram where 3 MODULED are linked :
This system is only designed to offer a convenient way of matching the pixel distance between each MODULED 150 to offer excellent matrix characteristics it must not be moved or carried thus formed, to do so risks breakage of various elements on this assembly or fixture colapse.
03. OPTIONAL FILTER HOLDER SETUP :
An optional external filter holder is available as an option for your MODULED 150 (AYRTON product code: 025392).
This allows you to insert a filter especially for beam angle increasing of MODULED 150. A wide range of diffusion filters is available as an option for such use.
The filter holder also allows mounting of various optional accessories on your MODULED 150, such as Cap (Full Barndoor), Semi-cap (Half Barndoor), Matrix horizontal masking (Horizontal Barndoor) or Vertical masking Matrix (Vertical Barndoor).
All references and specific characteristics of all these optional accessories can be found in the Accessories section of this manual.
The optional external holder filter kit is composed of 3 parts, 2 plastic clips to be installed on the front of the MODULED150, and holder filter allowing to drop the filter
6
06. INSTALLATION
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 7
in and maintain the diffusion filter (this filter, available in different versions, is not supplied in the kit external filter holder and must be ordered separately). The various components of this kit external filter holders are represented on the following basis : (The MODULED 150 is represented here only for illustration, it is not part of Kit external filter holder)
Caring in the Side 2 clips set up, according to the drawing above. The 2 clips side of this kit can be fastened on either side of the device and are held in place by locking in the wings at the back of the fixture body, as shown in the following diagram :
The diffusion filter slips into the filter holder in the following way:
Once the filter holder equipped with its diffusion filter, you can now drag into one of the grooves clips, the mounted kit of MODULED 150 corresponds to the following :
04. MOUNTING THE FILTER WITHIN THE MODULED 150
As part of a fixed installation, it is possible under certain conditions described below to install an optional diffusion filter directly in the MODULED 150.
This requires the opening of the unit, the establishment of a filter previously designed for this specific use, and replacement of the front panel respecting the special constraints of compression gasket.
WARNING:
During that operation, you will have direct access to sensitive electronic components of the device, and improper handling can cause a malfunction or even a defect in fixture water resistance.
The AYRTON guarantee will not be applicable if a malfunction or leakage occurs after installation of an interior filter.
If you have any doubt about this feature, don’t do it yourself!
Contact your AYRTON dealer, they will be able to do it for you.
However, if you want to continue this operation, here in detail the procedure to be followed.
First, it is necessary to adjust the diffusion filter dimensions to be correctly installed in the MODULED
150.
Use only AYRTON filters inside the fixture, the use of any other type of filter non marketed by AYRTON is excluded and could result in the deterioration of your MODULED
150.
The dimensions of the special AYRTON diffusion filter MODULED 150 are 440 mm x 100 mm.
These dimensions are provided for use of this filter kit with the external filter holder (AYRTON product code:
025392) detailed in a previous section of this manual.
This filter to be installed directly in the MODULED 150, shall be cut in the following sizes (in millimeters) :
The MODULED 150 may now be opened for the insertion of the diffusion filter. A few tools are needed, as a 3mm BTR key and a game of thickness hold.
7
06. INSTALLATION
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
430
64
±1 41
at 45˚
10
±1
99
±1
99
Page 8
The operation is illustrated on the following chart :
Operation details :
Put your MODULED 150 on a work surface adapted and
free from dirt, dust and various liquids.
With a BTR 3mm key, loosen the 4 front fixture screws, and
then conclude with the 4 screws located at the corner of the front panel.
Gently remove the front, and then remove the silicone seal
also.
Warning, from that moment, you have access to the electronic system of the MODULED 150, work with concentration and care.
Put down the fixture front cover upon your work area taking
care not to place the moduled on any objects that may damage the device, screen down and seal housing upwards.
Set up the diffusion filter (previously cut) in the space
available inside the front, caring to place the portion of the filter holes dedicated to infrared keys of the fixture in front of those holes.
Place the joint in the slot provided on the front panel of
MODULED 150.
Gently remove the body of MODULED 150, keeping special
attention to correctly placing the seal on the entire periphery of the device.
Keep your hands between the front and the body of the
fixture, then return it, front upwards. Replace the 8 screws on the front panel in place by screwing on a few turns only, leave the screws loose.
Tighten the 4 first central screws, in order to leave a gap
of 2 mm between the front and the body of the fixture, and
make sure the gasket stays in place during this phase.
Repeat this process for the 4 corner screws of the front
panel.
With a the game shims installed, tighten the screws one
by one, leaving a distance between the front and the body
of the device of 1.5 mm.
The operation is now over, it remains to verify the correct operating of your MODULED 150 before it is permanently installed.
05. PROJECTOR RIGGING
Your MODULED 150 can mounted on a structure in any position without affecting its operation.
To install your MODULED 150, you must use suspension collars with thread M10 (not supplied). They must be
licensed and able to withstand a load 10 times greater than the weight of the projector for 1 hour and without any distortion.
Attach the necklace suspension on the central hole of the fixture’s yoke with a M10 screw and a nut (these elements make screws should be a minimum 8.8 grade). Use washers M10 between the different elements, and make sure the fixing once tightened will not go loose. The use of star washers or Nyloc Nut is recommended.
Before hanging your MODULED 150 to the structure, make sure that the associated accessories (filter holder, for example) are properly set.
Hang your MODULED 150 on the structure by placing the front of the base to the area to be illuminated. Make sure you are locking collars suspension.
You must install an independent safety sling to supplement the failure of the main suspension. This sling security shall be capable of withstanding a load 10 times greater than the weight of the projector. The safety bond must be set at the ring of security MODULED 150. This ring of security, supplied with the unit should be screwed into the body of the fixture as described in the Description section of this manual.
The following diagram illustrates the correctness hanging of a MODULED 150 on a support-type tubular structure
06. MODULED 150 CONNECTION
Your MODULED 150 can not work alone. Its use requires the use of a connection box EASYBOX HD (AYRTON Code: 075130) and specific AYRTON cables of various length. The use of an external controller issuing a command signal format DMX512 is also required.
The MODULED 150 can be connected in series with each other through the use of specific AYRTON cables, the exit of previous MODULED 150 being connected to the entrance to the following MODULED 150. The power supply for the fixtures passes through the box connection EASYBOX HD.
The command signal DMX 512 also passes by the connection box EASYBOX HD.
The following diagram illustrates the connection of a series of MODULED 150 :
8
06. INSTALLATION
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 9
THE MODULED 150 has an internal universal power supply, so it can work in either 110 AC, AC 208V or 230V AC.
However, the currents vary for each mains voltage level. It is necessary to adjust the amount of MODULED 150 that can be connected in series in a row in terms of the sector and lengths of cable used.
The Maximum current consumption of the line composed of MODULED 150 should never exceed 10A.
The table below will indicate the amount of MODULED 150 which can be connected on a single connection box EASYBOX HD depending on the conditions of use :
Connecting the EASYBOX HD, and therefore your MODULED 150, on a dimmer highly deteriorates these devices!
The EASYBOX HD (and therefore your MODULED 150) must be connected to the Earth.
On the last MODULED 150 of the line, it is recommended to place a specific AYRTON cap DMX line ending. The AYRTON code of this optional accessory is: 025398.
IF you do not use this accessory, be sure to set up on the output connector of the last MODULED 150 of the line the cap seal of origin, came with the device.
WARNING:
Never perform connection or disconnection of any cable from the MODULED 150 line without power off before the connection box EASYBOX HD.
The Golden Rule is particularly important for MODULED 150, unless you risk to damage the products.
The connection of 2 MODULED 150 side by side needs a hybrid multifunction 0.28 m cable length.
The multifunction connectors installed on the multipurpose AYRTON cables for connecting the MODULED 150 are elements watertight locking.
Their correct use requires an understanding of the method of connection or disconnection appropriate to use.
You must not turn the body connectors, but act on the locking ring for their connection or disconnection. Failure to comply with this rule can cause damage to the cables and risk breaking your MODULED 150 when used with a cable.
Voltage 230V AC: Maximum 10 MODULED 150 Connected in series in a sector line.
Voltage 110 V AC: Maximum 5 MODULED 150 Connected in series in a sector line.
In any case, do not exceed a 50 meters length between EASYBOX HD and the last MODULED 150 of the line, consisting in several devices connected in series.
THE MODULED 150 has an internal universal power supply, so it can work in either 110 VAC, 208 VAC or 230 VAC.
However, the currents vary for each mains voltage level. It is necessary to adjust the amount of MODULED 150 that can be connected in series in a row in terms of the sector and lengths of cable used.
The Maximum current consumption of the line composed of MODULED 150 should never exceed 10A.
The table below will indicate the amount of MODULED 150 which can be connected on a single connection box EASYBOX HD depending on the conditions of use :
Connecting the EASYBOX HD, and therefore your MODULED 150, on a dimmer highly deteriorates these devices!
The EASYBOX HD (and therefore your MODULED 150) must be connected to the Earth.
On the last MODULED 150 of the line, it is recommended to place a specific AYRTON cap DMX line ending. The AYRTON code of this optional accessory is: 025398.
If you do not use this accessory, be sure to set up on the output connector of the last MODULED 150 of the line the cap seal of origin, came with the device.
WARNING:
Never perform connection or disconnection of any cable from the MODULED 150 line without power off before the connection box EASYBOX HD.
This Golden Rule is particularly important for MODULED 150, unless you risk to damage the products.
The connection of 2 MODULED 150 side by side needs a hybrid multifunction 0.28 m cable length.
The multifunction connectors installed on the multipurpose AYRTON cables for connecting the MODULED 150 are elements watertight locking.
Their correct use requires an understanding of the method of connection or disconnection appropriate to use.
You must not turn the body connectors, but act on the locking ring for their connection or disconnection. Failure to comply with this rule can cause damage to the cables and risk breaking your MODULED 150 when used with a damaged cable.
Voltage 230 VAC: Maximum 10 MODULED 150 Connected in series in a sector line.
Voltage 110 VAC: Maximum 5 MODULED 150 Connected in series in a sector line.
In any case, do not exceed a 50 meters length between EASYBOX HD and the last MODULED 150 of the line, consisting in several devices connected in series.
9
06. INSTALLATION
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
CABLE MAX. LENGTH : SEE MANUAL
MAX. MODULED 150 QUANTITY : SEE MANUAL
EASYBOX HD
MAIN SUPPLY
XLR 3 PIN DMX CABLE
DMX SPLITER
DMX SIGNAL
DMX LIGHTING DESK
120 DMX TERMINATOR CONNECTOR FOR MODULED 150
TO OTHER MODULED 150 CHAINS
TO OTHER DMX FIXTURES
Page 10
The charts below show you how :
The connection box EASYBOX HD comes without power cable. A detailed lockable and removable type PowerCON (Model filed NEUTRIK) is provided with the EASYBOX HD, for the purpose of adapting a power cord with a Male plug corresponding to the standard of your country.
Depending on the country, the identification of cables sector is different.
You are reminded below, in order to achieve a cable line.
To put power up your MODULED 150, it must first have been connected as described above. Then turn to the right description of the PowerCON EASYBOX HD enclosure to feed your MODULED 150.
To cut off power to your MODULED 150, you pull the tab to unlock position in the PowerCON, then turn this portfolio to the left, then finally remove this portfolio Enclosure this connection EAXYBOX HD. Your MODULED is now powered off.
07. DMX 512 CONNECTIONS
The cables used for routing the DMX512 signal command until EASYBOX HD connection box that powers your MODULED 150 must conform to the standards EIA 422A & EIA 485. Make sure to use the shielded cable to twisted pair. Never use a microphone cable, it does not permit reliable transmission over long distances. For lengths in excess of 300 meters, it is advisable to use an amplifier line.
Connect the cable from your DMX controller on the EASYBOX HD base DMX IN connection that feeds your MODULED 150.
The base DMX IN Enclosure of the EASYBOX HD is the 3-pin XLR.
The pin wiring is as follows:
1. DMX GND
2. DATA (-)
3. DATA (+)
The connection box EASYBOX HD has no DMX exit, as the DMX 512 standard prohibits the DMX signal 512 wiring in star, only the wiring in series of different DMX receptors (including MODULED 150).
If you need to use more than one line consisting of one or more MODULED 150, or other devices controlled by DMX with your DMX controller, it is necessary to use a DMX Splitter allowing you from a line of DMX512 to obtain several DMX512 lines identical but separate.
The use of this device offers the advantage of protecting the different lines DMX obtained by an electrically insulating, sharply limiting the damage that can occur in the event of damage to one of the devices in the DMX channel. This type of device is offered by a wide variety of specialized manufacturers in DMX signal 512 management.
To ensure reliable transmission of DMX information, it is imperative to complete the DMX 512 line with a DMX terminating cap specific to AYRTON. This is to be put in place on the last MODULED 150 of the line. The Code AYRTON this optional accessory is: 025398.
If you do not use this accessory, be sure to set up on the output connector of the last MODULED 150 of the line, cap seal of origin, came with the device.
Connections Marks
Wire Contact International UK
Brown Phase L Red
Blue Neutre N black
Yellow/Green Earth EARTH Green
10
06. INSTALLATION
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Connect
1
2
Disconnect
1
2
Page 11
07. PROTOCOL
The MODULED 150 is available in several versions of LED light sources.
The different versions offered are:
MODULED 150 RGB
This projector combines LED sources such as RED, GREEN and BLUE, which provides a palette of 16.7 million colours, colours additive.
MODULED 150 AWW
This projector combines LED sources of WHITE and AMBER, which provides a white light color temperature varies.
AWB MODULED 150
This projector combines LED sources such as WHITE, BLUE and AMBER, which provides a white light variable color temperature larger than the model version AWW.
Depending on the type of MODULED 150 used, the DMX of these devices is different, the number of channels required for DMX control varies.
In addition, these modes have several DMX settings, which provide extensive opportunities, you can actually adjust the number of channels DMX necessary for the operation of the fixture.
A flexible control by the user according to its specific needs is then proposed.
01. MODULED 150 RGB DMX PROTOCOL
The MODULED 150 RGB can be configured in different 6 DMX MODES. The DMX mode that suits best the user is selected via the MODE menu of the fixture.
MODE 3 channels DMX (03cH)
1. RED (For all 18 LEDS Matrix)
2. GREEN (For all 18 LEDS Matrix)
3. BLUE (For all 18 LEDS Matrix)
MODE 4 channels DMX (04cH)
1. RED (For all 18 LEDS Matrix)
2. GREEN (For all 18 LEDS Matrix)
3. BLUE (For all 18 LEDS Matrix)
4. DIMMER (0 : dimmer closed => 255 : dimmer opened)
MODE 6 channels DMX (06cH)
1. RED (For all 18 LEDS Matrix)
2. GREEN (For all 18 LEDS Matrix)
3. BLUE (For all 18 LEDS Matrix)
4. STROBE (0 : no strobe > to 255 : extensive strobe effect)
5. COLOR (0 : Slow colour variation > 255 :
MACRO fast colour variation)
6. DIMMER (0 : dimmer closed > 255 : dimmer opened)
MODE 9 channels DMX (09cH)
1. RED (For 18 LEDS Matrix n°1)
2. GREEN (For 18 LEDS Matrix n°1)
3. BLUE (For 18 LEDS Matrix n°1)
4. RED (For 18 LEDS Matrix n°2)
5. GREEN (For 18 LEDS Matrix n°2)
6. BLUE (For 18 LEDS Matrix n°2)
7. RED (For 18 LEDS Matrix n°3)
8. GREEN (For 18 LEDS Matrix n°3)
9. BLUE (For 18 LEDS Matrix n°3)
MODE 10 channels DMX (10cH)
1. RED (For 18 LEDS Matrix n°1)
2. GREEN (For 18 LEDS Matrix n°1)
3. BLUE (For 18 LEDS Matrix n°1)
4. RED (For 18 LEDS Matrix n°2)
5. GREEN (For 18 LEDS Matrix n°2)
6. BLUE (For 18 LEDS Matrix n°2)
7. RED (For 18 LEDS Matrix n°3)
8. GREEN (For 18LEDS Matrix n°3)
9. BLUE (For 18LEDS Matrix n°3)
10. DIMMER (0 : dimmer closed > 255 : dimmer opened)
MODE 12 channels DMX (12cH)
1. RED (For 18LEDS Matrix n°1)
2. GREEN (For 18LEDS Matrix n°1)
3. BLUE (For 18LEDS Matrix n°1)
4. RED (For 18LEDS Matrix n°2)
5. GREEN (For 18LEDS Matrix n°2)
6. BLUE (For 18LEDS Matrix n°2)
7. RED (For 18LEDS Matrix n°3)
8. GREEN (For 18LEDS Matrix n°3)
9. BLUE (For 18LEDS Matrix n°3)
10. STROBE (0 : no strobe > to 255 : extensive strobe effect)
11. COLOR 0 : Slow colour variation > 255 :
MACRO fast colour variation)
12. DIMMER (0 : dimmer closed > 255 : dimmer opened)
02. MODULED 150 AWW DMX PROTOCOL
The MODULED 150 RGB can be configured in different 6 DMX MODES. The DMX mode that suits best the user is selected via the MODE menu of the fixture.
MODE 2 channels DMX (02cH)
1. AMBER (For all 18 LEDS Matrix)
2. WHITE (For all 18 LEDS Matrix)
MODE 3 channels DMX (03cH)
1. AMBER (For all 18 LEDS Matrix)
2. WHITE (For all 18 LEDS Matrix)
3. DIMMER (0 : dimmer closed > 255 : dimmer opened)
MODE 5 channels DMX (05cH)
1. AMBER (For all 18 LEDS Matrix)
2. WHITE (For all 18 LEDS Matrix)
3. STROBE (0 : no strobe > to 255 : fast strobe effect)
4. COLOR (0 : AMBER > 128 : AMBER + WHITE
TEMP. > 255 : WHITE)
5. DIMMER (0 : dimmer closed > 255 : dimmer opened)
MODE 6 channels DMX (06cH)
1. AMBER (For 18LEDS Matrix n°1)
2. WHITE (For 18LEDS Matrix n°1)
3. AMBER (For 18LEDS Matrix n°2)
4. WHITE (For 18LEDS Matrix n°2)
5. AMBER (For 18LEDS Matrix n°3)
6. WHITE (For 18LEDS Matrix n°3)
11
07. PROTOCOL :
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 12
MODE 7 channels DMX (07cH)
1. AMBER (For 18LEDS Matrix n°1)
2. WHITE (For 18LEDS Matrix n°1)
3. AMBER (For 18LEDS Matrix n°2)
4. WHITE (For 18LEDS Matrix n°2)
5. AMBER (For 18LEDS Matrix n°3)
6. WHITE (For 18LEDS Matrix n°3)
7. DIMMER (0 : dimmer closed => 255 : dimmer opened)
MODE 9 channels DMX (09cH)
1. AMBER (For 18LEDS Matrix n°1)
2. WHITE (For 18LEDS Matrix n°1)
3. AMBER (For 18LEDS Matrix n°2)
4. WHITE (For 18LEDS Matrix n°2)
5. AMBER (For 18LEDS Matrix n°3)
6. WHITE (For 18LEDS Matrix n°3)
7. STROBE (0 : no strobe > to 255 : TEMP. fast strobe effect)
8. COLOR (0 : AMBER > 128 : AMBER + WHITE
> 255 : WHITE)
9. DIMMER (0 : dimmer closed > 255 : dimmer opened)
03. MODULED 150 AWB DMX PROTOCOL
The MODULED 150 RGB can be configured in different 6 DMX MODES.
The DMX mode that suits best the user is selected via the MODE menu of the fixture.
MODE 3 channels DMX (03cH)
1. AMBER (For all 18 LEDS Matrix)
2. WHITE (For all 18 LEDS Matrix)
3. BLUE (For all 18 LEDS Matrix)
MODE 4 channels DMX (04cH)
1. AMBER (For all 18 LEDS Matrix)
2. WHITE (For all 18 LEDS Matrix)
3. BLUE (For all 18 LEDS Matrix)
4. DIMMER (0 : dimmer closed > 255 : dimmer opened)
MODE 6 channels DMX (06cH)
1. AMBER (For all 18 LEDS Matrix)
2. WHITE (For all 18 LEDS Matrix)
3. BLUE (For all 18 LEDS Matrix)
4. STROBE (0 : no strobe => to 255 : fast strobe effect )
5. COLOR (0 : AMBER => 64 : AMBER + WHITE TEMP. > 128 : WHITE >192 : WHITE + BLUE
> 255 : BLUE)
6. DIMMER (0 : dimmer closed => 255 : dimmer opened)
MODE 9 channels DMX (09cH)
1. AMBER (For 18 LEDS Matrix n°1)
2. WHITE (For 18 LEDS Matrix n°1)
3. BLUE (For 18 LEDS Matrix n°1)
4. AMBER (For 18 LEDS Matrix n°2)
5. WHITE (For 18 LEDS Matrix n°2)
6. BLUE (For 18 LEDS Matrix n°2)
7. AMBER (For 18 LEDS Matrix n°3)
8. WHITE (For 18 LEDS Matrix n°3)
9. BLUE (For 18 LEDS Matrix n°3)
MODE 10 channels DMX (10cH
1. AMBER (For 18 LEDS Matrix n°1)
2. WHITE (For 18 LEDS Matrix n°1)
3. BLUE (For 18 LEDS Matrix n°1)
4. AMBER (For 18 LEDS Matrix n°2)
5. WHITE (For 18 LEDS Matrix n°2)
6. BLUE (For 18 LEDS Matrix n°2)
7. AMBER (For 18 LEDS Matrix n°3)
8. WHITE (For 18 LEDS Matrix n°3)
9. BLUE (For 18 LEDS Matrix n°3)
10. DIMMER (0 : dimmer closed => 255 : dimmer opened)
MODE 12 channels DMX (12cH)
1. AMBER (For 18 LEDS Matrix n°1)
2. WHITE (For 18 LEDS Matrix n°1)
3. BLUE (For 18 LEDS Matrix n°1)
4. AMBER (For 18 LEDS Matrix n°2)
5. WHITE (For 18 LEDS Matrix n°2)
6. BLUE (For 18 LEDS Matrix n°2)
7. AMBER (For 18 LEDS Matrix n°3)
8. WHITE (For 18 LEDS Matrix n°3)
9. BLUE (For 18 LEDS Matrix n°3)
10. STROBE 0 : no strobe > to 255 : fast strobe effect ) 11
.
COLOR (0 : AMBER > 64 : AMBER + WHITE TEMP. > 128 : WHITE >192 : WHITE + BLUE
> 255 : BLUE)
12. DIMMER (0 : dimmer closed > 255 : dimmer opened)
08. CONTROL
The MODULED 150 has an integrated user interface, composed of a 4-digit LED display and 4 buttons located on the fixture’s front. These elements provide access to the drop-down menu MODULED 150 authorizing the consultation or change its parameters, such as:
DMX Address
Modes of operation ( DMX channels figure )
Hour Count Schedule
Internal Temperature
Software version
And many more…
01. INFRA-REDS KEYS
Searching in the drop-down menu MODULED 150 is effected by means of 4 infra- RED keys located on the front of the fixture. The functionality of these keys which described below.
MODE Key
Performs a step backwards in the tree of dropdown Allows you to return to your base display
UP Key
Go to the next section of the menu Allows a selected value increment
DOWN Key
Scrolls to the previous menu item Allows a decrement selected value
12
08. CONTROL
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 13
ENTER Key
Lets go into a section of the drop-down menu Validates selection
The infra-REDs keys self-adjust every time power is applied to the MODULED 150, and then continuously during use, to operate in accordance with the external light conditions.
Indeed, according to the ambient lighting conditions where is the MODULED 150, infrared radiation perceived by these keys is different and must be taken into consideration.
During this Power On phase, which lasts a few seconds, MODULED 150 does not take into account the orders it receives from DMX, and the device display presents 4 points from the bottom lit. You should not touch these keys during this phase.
Please note that when using the optional external filter holder installed on the MODULED 150, you do not have access to infra-red keys.
In this scenario, set up your MODULED 150 without the filter holder, and then put it off. Then install the filter holder, put your MODULED 150 switched on. It will function properly.
A lighting sources with a big amount of infra-red rays (sunlight, fluorescent tubes based light, …) can interfere with the proper functionning of the keys of the device. Make sure to reduce the illumination of the MODULED 150 keys by such lighting during the calibration.
A simple method is to put one hand on the top of the display/keys area to mask light, while the other hand acts on keys to navigate into the MODULED 150 menu.
02. DISPLAY
A 4-digit LEDS display can read information from the drop­down menu on the device. This display looks like the following:
The MODULED 150 default display (when it is unlocked) corresponds to the DMX address settled on it (001 in DMX address in the illustration above). The display “A001” for example shows that the unit is set to DMX address 001, and that its 1st channel control reacts at 001. It should be noted that the MODULED 150 is set default address DMX 001 from factory.
The fixed point turned to the left of the display is an indicator of the voltage presence. This light, which remains lit even when the MODULED150 is in Stand-by mode, ensured that the device is powered.
If a DMX signal is present, the point at the bottom right of the display flickers once every second to indicate the presence of the command signal. This light is active even though the MODULED 150 is into standby mode.
03. STAND BY MODE : MODULED 150 UNLOCKING
If no action is taken on the keys of MODULED 150, the device rapidly turns into Stand-by mode.
In this mode, MODULED 150 is operational, but the display is turned off, only remain on the presence of witnesses Voltage (permanent ignition) and DMX presence (flashes once per second if the signal is present DMX).
The display of MODULED 150 present in this mode look like the following :
Power Presence indicator DMX Presence indicator
To unlock the MODULED 150 when it is in the Standby mode, you must :
Press simultaneously MODE and ENTER keys. (2 points in the middle of the display are illuminated)
Then press simultaneously UP and DOWN keys.
The display of MODULED 150 becomes active, you can then change its settings or review information for the fixture, which are stored in its internal memory.
If you do not touch its keys, MODULED 150 then goes very quickly on STANDBY mode automatically.
13
08. CONTROL
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 14
09. MODULED 150 MENU
9-1- MODULED 150 MENU CHART
The drop-down MODULED 150 menu is organized as follows:
02. DMX ADRESS MENU
This menu lets you adjust the DMX address of MODULED 150.
Press the Enter key. A flashes on the display. Using the Up and Down keys to settle DMX desired address for the device. Press the Enter key to validate your selection, or the Mode key to emerge from this menu without applying your changes of address DMX.
03. DMX MODE MENU
This menu allows you to set the modes of operation of MODULED 150. This mode of operation determines the number of DMX channels required for the control of MODULED 150. The number of channels of DMX control available differs depending on the nature of your MODULED 150.
If your MODULED 150 version is RGB (combination of LEDs RED / GREEN / BLUE), or versions AWB (combination of LEDs AMBER / WHITE / BLUE), the number of control channels available is user selectable :
MODEADDR
14
09. MODULED 150 MENU
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
)
n
)
. .
Axxx
Stand By Mode (Unlock to access menu)
Basic Display
Addr Axxx Axxx
ModE xxCH xxCH
OPT
DIMM d.inv d.nor
dFLt
Restore Default Parameters
LUMI ArcH Entr
InFo Sn xxxxxxx
Curr
Hour
temP
SoFt
AWW
HuSr Htot
tuSr t mA tcur
Vx.x.x
DMX address Set Up
DMX Mode Set up
or
or
Serial Number Display
RGB
or
Software version
Reverse Dimmer
Lighting Power limitation
View Led type intalled
Utilization counter (Reset possible by long pressure on Enter key ) Total time counter
Unlock menu by pressing :
Mode + Enter (simultaneously
the
Up + Down (simultaneously
Key functions :
Mode = back Enter = save
Up = next
Down = Previous
Resetable Max Temperature
Non Resetable Max Temperature Actual Temperature
Page 15
3 channels DMX (03cH)
4 channels DMX (04cH)
6 channels DMX (06cH)
9 channels DMX (09cH)
10 channels DMX (10cH)
12 channels DMX (12cH)
If your MODULED 150 version is AWW (combination of LEDs and AMBER WHITE), the number of control channels available is user selectable :
2 channels DMX (02cH)
3 channels DMX (03cH)
5 channels DMX (05cH)
6 channels DMX (06cH)
7 channels DMX (07cH)
9 channels DMX (09cH)
Press the Enter key. cH flashes on the display.
Using the Up and Down keys to adjust the DMX mode desired for the fixture. Press the Enter key to validate your selection, or the Mode button to emerge from this menu without apply your changes to the number of DMX channels exploited.
04. OPTIONS MENU
This menu provides access to MODULED 150 options. This menu is divided into 3 sections: DIMMER / DEFAULT / BRIGHTNESS, by pressing Up and Down on the fixture.
01. DIMMER
This menu is used to determine the meaning of variation of dimmer (dimmer).
Dimmer reversed (d.inv)
The operation of the dimmer is inversely proportional to the change in command DMX. If the value of orders DMX is 0%, Dimmer is open. If the value of DMX command is 100%, Dimmer is closed.
Dimmer normal (d.nor)
The operation of the dimmer is proportional to the change in command DMX. If the value of orders DMX is 0%, Dimmer is closed. If the value of DMX command is 100%, Dimmer is open.
Press the Enter key. d. Flashes on the display. Using the Up and Down keys to adjust the control Dimmer wanted for the unit. Press the Enter key to validate your selection, or the Mode key to emerge from this menu without applying your changes to the Dimmer.
02. DEFAULT VALUES
This menu allows you to restore the default values paid in the MODULED 150 factory output, namely:
DMX Address: 001
DMX Mode: 12-channel DMX (RGB version)
9-channel DMX (AWW and AWB version)
In this menu, press Enter : 4 points of the display is lit one by one, then the display back on the display (dFLt). The MODULED 150 took over the original factory settings. Push Mode
to break this menu.
03. BRIGHTNESS
This menu allows you to set the fixture’
s brightness.
There are 2 distinct modes in MODULED 150 :
Mode “Entertainment” (Entr), which allows you to
maximize the power of the device, depending on temperature conditions outside. When the MODULED150 is cold, the available power is maximum. If the temperature rises too, MODULED 150 will reduce its power to secure its temperature. This mode is recommended for ephemeral events where lighting of MODULED 150 must be optimal.
The “Architectural Style” (ArcH), which guarantees a
stable luminous flux of the fixture, in return for a light output lower than for the way “Entertainment”. This mode is called for as part of the fixed installations MODULED 150 where the constant flux is important. It is also recommended to use this mode where the MODULED 150 is often asked to values close to 100% of its power.
In this menu, press the Enter key. The mode Entertainment (Entr) or Architectural (ArcH) appears as appropriate. Press again the Enter key is flashing selection. Acting on the keys Up or Down to change the selection. Press the Enter key to validate your selection, or the Mode key to emerge from this menu without apply your changes.
LUMI
DFLT
dimm
oPt
15
09. MODULED 150 MENU
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 16
05. INFORMATIONS MENU
This menu gives access to certain information available on the MODULED 150.
This menu offers 5 topics, Serial Number / Release
Software / temperature / Counter Schedule / Setting versions of LEDs, by pressing Up and Down the
fixture.
01. SERIAL NUMBER
This menu lets you see the MODULED 150 number (ID number). It is this issue which is recognized by the interface settings of optional external COUGAR 2.
This number is also reported on a label (ID. Number) affixed to the hood power of the device.
Press Enter, the number of the fixture on display scrolls.
Press the Mode key to emerge from this menu.
02. SOTWARE VERSION
This menu allows you to view the software version installed in the MODULED 150. Press the Enter key. The software version appears on the display, type
vX.X.X Press the Mode key to emerge from this menu.
03. TEMPERATURE
This menu allows you to view the internal temperature of the device. This menu offers 3 topics accessible by the Up and Down keys to the fixture :
User Temperature (tuSr), which can be rewound.Maximum temperature (tmA), which can not be
rewound.
Current Temperature (tcur)
USER TEMPERATURE
Press the Enter key. The display shows information on the type t XX where XX is the maximum temperature in Celsius (°C)
recorded by the fixture since the last reset of this parameter. Maintaining the Enter key pressed for 3 seconds to deliver this value to zero if necessary, and if not then press the mode button to exit.
MAXIMUM TEMPERATURE
Press the Enter key. The display shows information on the type t XX where XX is the value of the maximum internal temperature recorded since the beginning of the existence of MODULED 150. (Also value expressed in Celsius). This value can not be rewound. Press the Mode key to exit.
ACTUAL TEMPERATURE
Press the Enter key. The display shows information on the type tXX, where
XX is the value of instant the internal temperature of the MODULED 150, expressed in degrees Celsius.
Press the Mode key to exit.
04. SCHEDULE COMPTER
In this menu you can see the age of the fixture, expressed in hours. This menu offers 2 topics accessible by the Up and Down keys to the device:
Count Schedule user (HuSr), which can be reset.Count Hours Total (Htot), which can not be reset.
COUNT USER SCHEDULE
Press the Enter key. The display shows information on the type H XX.X,
XX.X which is the number of hours of use MODULED 150 since the last reset of this parameter.
When the number of hours above a specific level on 3 displayable characters, this value becomes scrolling on the display.
Maintaining the Enter key pressed for 3 seconds to deliver this value to zero if necessary, and if not then press the Mode button to exit.
HuSr
Hour
TCUR
T ma
TUSR
TEMP
Soft
Sn
info
16
09. MODULED 150 MENU
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 17
TOTAL COUNT SCHEDULE
Press the Enter key. The display shows information on the type H XX.X,
XX.X which is the total hours of operation of MODULED 150.
This value can not be rewound. Press the Mode key to exit.
05. LEDS COLOURS PRE-SET
This menu shows for what kind of combination of LED light sources the electronics of MODULED 150 is optimized.
Indeed, the control of LEDs different nature imposes an adaptation of the internal parameters of command, and the number of DMX channels required by the apparatus varies depending on LEDs located in the latter.
This concept is not helpful to users of the device, it has to be verifiable by the technician responsible for maintaining the MODULED 150.
Press Enter. The display indicates (rgB), (Auu) or (AuB) depending on the model MODULED 150. Press the Mode key to exit.
10. SETTING THE MODULED 150 VIA COUGAR 2
The MODULED 150 can be set remotely with the interface AYRTON COUGAR 2 via wired DMX512 connection.
The COUGAR 2 connects directly DMX base present on the connection box EASYBOX HD that feeds the MODULED 150 you want to set.
The COUGAR 2 has the advantage that it can be used as a deported assignment device, but it is also possible to use USB interface for a computer-type PC.
A software AYRTON, COUGAR 2 MANAGER, lets you modify settings on MODULED 150 but also other luminaries of the AYRTON range quickly and simply, without having to intervene locally on each appliance.
Please consult the user manual COUGAR 2 for a detailed functionality offered by this system.
11. TECHNICAL SPECIFICATIONS
01. OPTICS
Optics secondary high efficiency PMMAOpen angle of the beam: 11 °Filters broadcasters optional
02. SOURCE
High Power LEDs No light source to replaceModel RGB: 18 LEDs REDs, 18 LEDs GREEN, BLUE 18
LEDs
Model AWW: 18 LEDs AMBERs, 36 LEDs WHITEModel AWB: 18 LED AMBERs, 18 LEDs WHITE, BLUE 18
LEDs
Total luminous flux: up to 3600 Lumen (RGB model)
up to 3000 Lumen (model AWW), up to 2400 Lumen (model AWB)
LEDs Lifetime estimated: 50,000 hours
03. COLOURS
System mixing colors RED, GREEN and BLUE design RGBSystem AMBER mix of colors and design WHITE AWWSystem AMBER mix of colors, and WHITE BLUE design
AWB
16.7 million colors and RGB models on AWB65536 colour shades on model AWWThe variation effect of colour automatic variable speed design
RGB
Canal colour temperature change of models on proportional
AWW and AWB
04. FROST, DIFFUSION
Filters broadcasters 13 °, 24 °, 33 ° or 42 ° available as an
option (Beam type Spot)
Filters broadcasters 33 ° x13 ° or 62 ° x16 ° Horizontal vertical
or available as an option (Beam type Ellipse)
05. DIMMER, STROBE
Electronic Dimmer for a perfect adjustment of the light from
0 to 100% with no variation in color
WHITE strobe effect or color with adjustable speed of 1 to
25 flashes per second
06. SOFTWARE FACILITIES
Addressing the projector and its parameters via integrated
control panel
Hours integratedTemperature DisplayDisplay abnormalitiesSetting remotely possible via the control box optional
COUGAR 2
Updating the software via the internal control box optional
COUGAR 2
curr
HTOT
17
09. MODULED 150 MENU
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 18
07. CONTROL
Controlling performance via DMX 512Input / Output DMX 512 connector via Hybrid 7 core multi-
functions
3, 4, 6, 9, 10 or 12 channels to choose DMX 512 models
on RGB and AWB
2, 3, 5, 6, 7 or 9 DMX 512 channels to choose and RGB
models on AWB
08. POWER SUPPLY
Active PFC Power Supply90 to 250 Volts - 50-60HzPower 150 WattsInput / Output power via multi-Hybrid 7 Core connector
functions
09. COOLING
Natural convection with control parameters
Protection against excessive temperature
10. CONSTRUCTION
Front side in tempered glassBody in Cast aluminiumSuspension yoke and stainless steel fastenersLED separate compartment to facilitate maintenance
operations
Protection index IP66
Exterior: black (Carbon) or gray (Platinum)
11. INSTALLATION
Removable suspension yoke Mounting system for assembling luminariesAttachment points for security cable
12. UTILIZATION SETTINGS
Operation Positions : allMaximum ambient temperature (Ta): 40°C (104 °F)Use Minimum Distance: 0.5 m (20in)
13. CONFORMITY
UE (EMC) : EN 50081-1, EN 50082-1 UE (Electric Security) : EN 60598-1, 60598-2-17
14. WEIGHT
6,4 Kg
15. PRODUCTS CODES
025200 : MODULED 150 RGB Carbon 025207 : MODULED 150 RGB Platinium 025210 : MODULED 150 AWB Carbon025217 : MODULED 150 AWB Platinium025220 : MODULED 150 AWW Carbon 025227 : MODULED 150 AWW Platinium
16. ACCESSORIES
025392 : Filter Holder025393 : Full Barndoor025394 : Half Barndoor025395 : Horizontal Barndoor025396 : Vertical Barndoor053313 : Diffusion Filter 13°053324 : Diffusion Filter 24°053333 : Diffusion Filter 33°053342 : Diffusion Filter 42°053372 : Diffusion Filter 33°
x 13° Horizontal
053373 : Diffusion Filter 33° x 13° Vertical053382 : Diffusion Filter 62° x 16° Horizontal 053383 : Diffusion Filter 62° x 16° Vertical077203 : Hybrid 7 Core multi-function cable , Length 0,28m077207 : Hybrid 7 Core multi-function cable , Length 0,70m077210 : Hybrid 7 Core multi-function cable , Length 1m077220 : Hybrid 7 Core multi-function cable , Length 2m077250 : Hybrid 7 Core multi-function cable , Length 5m077260 : Hybrid 7 Core multi-function cable , Length 10m077270 : Hybrid 7 Core multi-function cable , Length 25m077280 : Hybrid 7 Core multi-function cable , Length 50m075130 : EASYBOX HD Connection box025398 : Terminal DMX Connector 120 Ohms,
waterproof, 7 core
045330 : COUGAR 2
12. MAINTENANCE
The upkeep and maintenance of your MODULED 150 must be performed by a qualified person for this type of intervention.
Your MODULED 150 requests a regular maintenance whose frequency depends crucially on the environment and conditions of use.
An intensive use in a dusty area or absence of airflow around the device can cause operational disruptions that may result from overheat and cause damage that are not taken into the damaged covered by the warranty.
WARNING !
When servicing / maintaining / cleaning,
Moduled 150 power must be completely
turned OFF from Mains.
01. CLEANING
MODULED 150 must be regulary serviced and maintained. Presence of durst / impurity on any part of the unit can reduce lighting brightness, making MODULED 150 not working correctly.
Power of the projector must be completely turned OFF from
Mains.
Durst can form on or in between the rear side of the
projector (heatshink area). Gently blow to remove durst / impurity.
Clean glass surface with a light-dump cloth. Soft Glass
Detergent can also be used. Do not use aggressive product that can damage the glass or the paint. Avoid the use of any silicon-based products.
18
12. MAINTENANCE
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 19
02. SURPERVISION
Your plant must be subject to regular review by an approved organization. In addition, you must check each year following points by a qualified person :
The fastening system of the projector must be installed
properly and not with present evidence of corrosion.
The medium on which the projector is installed must have
no trace of distortion or corrosion.
Sling security must be attached to the slot.The mechanical parts shall not exhibit any signs of wear.The electrical cables must not have any signs of wear, cuts
or splice.
13. SOFTWARE UPDATE
Your MODULED 150 is planned for future developments. The software can be updated and you may benefit from the latest developments without having to open it.
The operation, which is carried out via DMX cable, using the COUGAR 2, requires only a few minutes and several projectors can be updated simultaneously.
System Requirements :
To update the software on your MODULED 150, you must have the following :
Central Command COUGAR 2.
PC (configuration: Windows 2000 or XP).
The COUGAR MANAGER 2 PC software
The file for updating the software version of MODULED 150
you want to install.
Please consult the user manual for COUGAR 2 details of this intervention.
14. WARRANTY
This product is guaranteed against any manufacturing defect during the period of one (1) year from the date of purchase of the fixture.
This guarantee does not support the footsteps of shock or damage to the device by a misuse of it, or use outside the conditions of use in this manual. Similarly, the blemishes due to normal wear and tear of the device can not be properly managed by the warranty.
Any modification of the fixture will invalidate the warranty. AYRTON can in no way be held responsible for the quality and consistency of the installation of this product, which is the responsibility of the installer.
The breakage of the window of the fixture is excluded from the guarantee. Only potential blemishes, provided that they are reported to the dealer from the AYRTON unpacking of the fixture and before any use of it, may be subject to assumption by the guarantee of this device.
19
13. SOFTWARE UPDATE
Reproduction of this document, entirely or in part, is strictly prohibited unless otherwised authorized. All rights reserved.
Page 20
Le parc de l’Événement
1, allée d’Effiat
F91160 - Longjumeau
France
Tél.: 33 (0) 1 69 10 33 90 Fax: 33 (0) 1 69 10 33 91 contact@ayrton.eu
www.ayrton.eu
Specifications subject to change without notice. AYRTON & MODULED are AYRTON S.A.R.L. registered trademarks. MODULED is a registered model. All rights reserved.
Loading...