A.Y. McDonald 747H20 User Manual

When the power goes out,
the Guardian takes over!
EMERGENCY
Water Powered Back Up
SUMP PUMP
Model 747H20
Protect your property during power outages or sump pump failure
Designed for the following uses:
•Ground water
•Sump crocks in homes, motels and hotels, schools, hospitals, industrial buildings, computer and record storage rooms
Features
•Made in the USA
•Designed for intermittent or continuous use
•Supplied with a backow preventer
•Made with high quality brass and PVC materials for corrosion resistance
•McDonald Hydro Drive optimizes performance
Specications
•Designed for de-watering
•Discharge size 1 1/4” PVC Sch. 80 (IPS)
•3/4” FNPT Inlet
•Min. pressure 29, max. 90
•Min. water temperature 32°F.
PUMPS | WATERWORKS | PLUMBING VALVES | GAS VALVES
A.Y. McDonald Mfg. Co.
800.292.2737
|
FAX 800.832.9296
|
The Guardian
consists of all
components
outlined in blue
pumps@aymcdonald.com
|
www.aymcdonald.com
®
10/11
Drive water from city water supply
Discharge pipe
Pressurized city water from Point A is converted to high velocity at the nozzle (Point
A
B). This velocity creates a vacuum at the top of the nozzle where flow enters the venturi.
B
The vacuum draws water through the suction screen, removing water from the sump through point C.
C
Water from sump
Suction screen
Sump Pump Operation
No Water Removed 5’ 7’ 9’ 12’ 15’ 18’ 21’ No Flow At:
30
480 420 360 228 192 0 0 18’
40
672 594 558 468 396 324 246 26’
60
750 750 750 750 750 750 750 40’
Inlet Pressure (PSI)
Water Powered
Performance in GPH
FEET of LIFT
®
BACKFLOW OPTIONS
ORDER MODEL 747H20-0001** 747H20-0002** BACKFLOW PROVIDED 3/4” Reduced 3/4” Pressure vacuum pressure assembly breaker assembly
ASSE STANDARD 1013 1020
OTHER APPROVALS
**Where required by code
Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California
Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California
Radon Ready
Model 747H20RR
Allows operating valve to be installed under cover for application where sump lid must be sealed.