Technical Information
Recommended water pressure 14.7 - 72.5 psi
Max. water pressure 145 psi
Recommended hot water temp. 120° - 140° F*
Max. hot water temp 176° F*
Hole size in mounting surface 1 3/8"
Max. mounting surface depth 1 3/8"
Flow rate – lavatory 1.5 gpm
Flow rate – bidet 2.2 gpm
Cartridge with high temperature limit stop
3/8" supply hoses
*Please know and follow all applicable local plumbing codes when
setting the temperature on the water heater.
2
Installation Considerations
For best results, Hansgrohe
•
recommends that this unit be
installed by a licensed, professional plumber.
Please read over these instruc-
•
tions thoroughly before beginning installation. Make sure that
you have all tools and supplies
needed to complete the installation.
Installation
Place the faucet and sealing ring on the mounting
surface.
Install the friction washer, metal washer, and mounting
nut.
Tighten the mounting nut by hand.
Check the position of the faucet. When satisfied, use
a slot-headed screwdriver to tighten the tensioning
screws.
Install the drain pull
rod.
Connect the hot and cold supply lines to the stops.
Use two wrenches, as shown in the
diagram, to prevent hose twisting.
Install the drain.
Set the high temperature limit stop (optional).
Turn on the water and check all connections for leaks.