Axor Showerpanel User Manual

Installation Instructions / Warranty
Interaktiv
Showerpanel
Interaktiv Showerpanel I Interaktiv Showerpanel II
Showerpanel I Showerpanel II
handshower & bodyjets handshower, bodyjets, tub spout Metro 06572000 06573000 Solaris 06549XX0 06550XX0 Stratos 06564XX0 06565XX0 Interaktiv S 06893000 06894000 Proaktiv* 06964000 06971000
Product Specification
Flow rate of handshower 2.5 gpm Flow rate of each bodyjet 1.0 gpm Maximum flow rate of thermostatic mixing valve 8 gpm @ 45 psi 10 gpm @ 65 psi Recommended incoming hot water temperature 120 Recommended incoming water pressure 45 – 72 psi Anodized aluminum body Listed by Underwriters Laboratories Backflow protection provided by check valve in handshower outlet. The high temperature limit stop on the thermostatic mixing valve cartridge can be re-set to comply with local plumbing codes -- see page 13.
*Proaktiv showerpanels are sold without trim. Proaktiv showerpanel trim kits are sold separately. **Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. In Massachusetts, the water heater may be set no higher than 112oF.
2
o
– 140o F**
Check Package Contents
Save time and aggravation. Before beginning installation, check the contents of this package. Make sure that all parts are present and in good condition. If any part is missing or damaged, please contact Hansgrohe Customer Service before proceeding.
Note: the handshower and Techniflex hose are not included with the Proaktiv showerpanel. They are included with the trim kit (sold sepa­rately).
Tools Required
The following tools are suggested for installing the Interaktiv Showerpanel: Tape measure
Level Grease pencil or other marking device Drill with 6 mm bit suitable for wall surface 10 mm nut driver 10, 11 and 19 mm wrenches 3 mm Allen wrench Philips screwdriver Waterproof sealant Mallet (to install anchors) Teflon
thread tape
3
Roughing-in
This unit can be installed on a flat wall or in a 90o corner. Instructions for installation on a flat wall begin on page 5. Go to page 8 if the panel is to be installed in a corner.
Ensure that you have a minimum 83” ceiling height from the standing surface.
Stub out 1/2" NPT male nipples for the hot and cold water supplies at the locations shown on the appropriate rough-in diagram. The nipples should extend 5/8" outside the surface of the finished wall.
Install the wall surface and make the wall watertight before installing the panel hangs on the finished wall. Seal the wall around the nipples with waterproof sealant.
Installation on a Flat Wall Installation in 90o Corner
. The panel
4
Installation -- Flat Wall
Wrap the threads on the supply nipples with Teflon thread tape.
Install the enclosed elbows so that the outlets face upwards.
Measure up the wall 78 ¾”, making sure that the line is plumb. Mark the position for the top screw hole.
From the position of the top screw hole, measure down 35 3/8”. Mark the position for the center screw hole.
From the center screw hole, measure down 19 1/8”. Mark the position for the bottom screw hole.
Use a 6 mm drill bit suitable for the wall surface. Drill the three screw holes.
Install the anchors. Seal the wall around the anchors with waterproof sealant.
Install the set screws in the top and bottom holes. Use a 10 mm nut driver to attach a nut to the top set
screw.
Slide the panel over the top and bottom set screws. Tighten the nut on the top set screw. Install and tighten the nut on the bottom set screw. Install one recessed head screw and the large washer on
the center hole. Tighten the screw.
5
Use the compression nuts and ferrules to connect the supply hoses on the panel to the supply elbows. Use two wrenches, as shown, to prevent the supply hoses from twisting.
Attach the seals to the side covers.
Install the side covers. The pins on the covers must go into the grooves on the sides of the panel.
6