ThermoBalance II Rough
06623000
ThermoBalance II Rough with Stops
06627000
The Service (Isolation) Stops
screwdriver
slots
The cartridge shown is included
with the trim kit.
(For the sake of clarity, the plastic installation box
(i-box) is not shown in these illustrations. The
i-box should not be removed.)
Rough-in 06627000 has service (isolation)
stops built onto the valve. When the screwdriver slots is horizontal, the stops are in the
“on” position. When the screwdriver slots are
vertical, the stops are in the “off” position.
When connecting the hot and cold supplies,
hold the stop steady with a wrench to avoid
stop mis-alignment, and breakage of the factory sealed thread compound.
Technical Specifications
Recommended pressure 45 - 72 psi
Maximum hot water temperature 165° F*
Recommended hot water temp. 120° - 140° F*
Nominal capacity @ 45 psi 8 gpm
Nominal capacity @ 60 psi 11.5 gpm
Safety stop 100° F
Maximum output temperature 110° F**
½” NPT connections
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater.
**The high temperature limit stop may be reset to comply with local plumbing codes. See page 11.
2
English
Installation Considerations
For best results, this unit should be installed by a licensed, professional plumber.
•
Large pressure differences between the hot and cold supplies should be balanced.
•
Before beginning the installation, please read the instructions thoroughly. Inspect the
•
product and make sure that all parts are present and in good condition. If you have
questions, contact Hansgrohe Technical Services.
ThermoBalance II rough 06623000 does not include service stops. If service stops are
•
required by local plumbing code, order the stops separately (part #06900300) or order
ThermoBalance II rough 06627000, which incorporates service stops.
The ThermoBalance II is intended for use in a two-function shower. DO NOT plug any
•
outlet.
The ThermoBalance II rough must be used with a ThermoBalance II trim kit. Do not at-
•
tempt to use with any other trim kit.
Do not attempt to use this valve in combination with a diverter tub spout.
•
Installation Suggestions
ok!ok!
no!
Do not use a diverter tub spout!
Use for a two-feature installation only! Do not plug either outlet!
3
English
Install the ThermoBalance II Rough
Caution: Turn the water off at the supply before
proceeding.
Both outlets must be plumbed. Do
not plug any port.
Install the hot and cold supply lines to the rough.
The hot supply must be connected to the hot inlet
and the cold supply must be connected to the cold
inlet. If the supplies are not connected to the correct
inlets, the valve cannot work correctly.
(for the sake of clarity, the plastic installation box is not shown in this illustration.)
If using model 06627000: When connecting
the hot and cold supplies, hold the stop steady with
a wrench to avoid stop mis-alignment, and breakage of the factory sealed thread compound.
Install both outlet lines.
The valve should be level in all planes. It should
be installed so that the outside surface of the
finished wall falls between the minimum and maximum lines on the installation box. This will insure
that the trim fits properly.
4
When finishing the wall, install the wall material up
to the oval installation box.
Do not remove the installation box.
When the trim is installed, the plaster shield portion
of the installation box will be trimmed nearly flush
to the wall and sealed to provide protection against
water damage.
Flush the supply lines using the flushing plug
The installation box includes a flushing plug to
permit line flushing and pressure testing before
the cartridge and finishing parts are installed. A
pressure test of the installed piping should be performed before the walls are closed.
The flushing plug permits cold water to flow from
the bottom outlet and the hot water through the top
outlet.
To flush the lines, install a hose bibb and hose
to each outlet line. (Using a hose will permit the
water to be directed to a location where it will
not cause damage.) Flush the lines for at least 5
minutes.
The porting in the flushing plug prevents cross flow.
However, it does not stop the flow of water through
the outlets.
English
5
English
These instructions cover these models:
Valve trim Shower set
only trim
C Lever 06064XX0 06082XX0
C Scroll 06065XX0 06083XX0
C Cross 06066XX0 06084XX0
Solaris² E 04147XX0 04150XX0
Allegro² E 04153XX0 04156XX0
Metro² E 04159XX0 04162XX0
Metris S 31317XX1 31324XX1
Focus S 31736XX1 31772XX1
Talis S 32317XX1 32324XX1
Solaris E 06636XX0 06642XX0
Stratos E 06580XX0 06586XX0
Metro E 06656XX0 06662XX0
06064XX0
06066XX006065XX0
These trim kits are for use with ThermoBalance II roughs 06623/06627 only.
Do not use with any other rough.
The finished wall must be complete and
made watertight before installation of
this trim kit.
04147XX004153XX004159XX0
31317XX131736XX132317XX1
06636XX0
6
06580XX006656XX0
Installation
Turn the water off at the main, or at the stops, before beginning.
Cut the plaster shield so that it extends 1/16”
outside the surface of the finished wall.
Seal the wall around the i-box with
waterproof sealant.
Failure to seal the wall can lead to
possible water damage.
Remove the label. Cut the support arms that
connect the flushing plug to the installation box.
Remove the flushing plug. Do not discard the
screws.
English
Be sure to remove the blue
flushing plug sealing gasket.
Failure to remove the gasket
can result in damage to the
cartridge and possible water
damage.
Insert the cartridge in the rough. Make sure that
the locator tab on the cartridge goes straight into
the notch in the rough.
Use the flushing plug screws to connect the
cartridge retainer plate to the rough. Tighten the
screws evenly, using a manual screwdriver, in a
cross-wise pattern. Do not overtighten the screws.
notch
locator
tab
7
English
Perform the following test to check for damage to the ceramic
plates inside the stop unit.
Failure to correctly perform this test can result in possible water
damage.
Turn on the water supplies. Grasp the stop unit
portion of the cartridge and turn it.
If there is a leak around the cartridge, turn the
supplies off, and remove the cartridge. Confirm
that the sealing gasket from the flushing plug was
removed.
Reinstall the cartridge. Turn the stop unit.
If the unit continues to leak, contact Hansgrohe
Customer Service for a replacement cartridge.
Solaris oval escutcheon only: Install the
white spacers on the carrier plate (a). Install two
Duotec strips on the spacers (b).
Install the remaining two strips on the back of the
escutcheon.
stop unit
a
All other models: Install two Duotec
strips directly on the carrier plate. Install
the remaining two strips on the back of the
escutcheon.
8
b
Install the carrier plate gasket and carrier plate
with the carrier plate screws.
Press the escutcheon very firmly over the carrier
plate, so that the strips of Duotec interlock, producing a very firm hold.
Install the handle: Tighten the handle screw,
using a 3 mm Allen wrench. For proper operation
of the valve, the handle screw must engage the
slot milled into the brass on the cartridge.
Set the high temperature limit stop (optional) -- see
page 11.
Justify the handle.
Justify the Handle
Tools required:
Thermometer
3 mm Allen wrench (included with trim kit)
Turn the valve on. Place the thermometer in the
water stream.
Turn the temperature control knob until the water
coming out measures 100° on the thermometer.
Turn the water off using the lever part of the
handle.
Use the 3 mm Allen wrench to loosen the set screw
on the bottom of the handle. Remove the handle
from the valve (1).
English
Hold the lever in one hand. With the other hand,
turn the temperature control knob approximately
½ turn clockwise (2a). Then, without pressing inward on it, turn it counter-clockwise until it is
positioned vertically and hits the safety stop (2b).
Reinstall the handle and tighten the set screw (3).