Axor 06064XX0 User Manual

Installation Instructions / Warranty
ThermoBalance II Rough & Trim
C Lever
06064XX0
Solaris² E
04147XX0
Metris S
31317XX1
C Scroll
06065XX0
Allegro² E
04153XX0
31736XX1
C Cross
06066XX0
Metro² E
04159XX0
Talis S
32317XX1
English
ThermoBalance II Rough 06623000 ThermoBalance II Rough with Stops 06627000
The Service (Isolation) Stops
screwdriver slots
The cartridge shown is included with the trim kit.
(For the sake of clarity, the plastic installation box (i-box) is not shown in these illustrations. The i-box should not be removed.)
Rough-in 06627000 has service (isolation) stops built onto the valve. When the screw­driver slots is horizontal, the stops are in the “on” position. When the screwdriver slots are vertical, the stops are in the “off” position.
When connecting the hot and cold supplies, hold the stop steady with a wrench to avoid stop mis-alignment, and breakage of the fac­tory sealed thread compound.
Technical Specifications
Recommended pressure 45 - 72 psi Maximum hot water temperature 165° F* Recommended hot water temp. 120° - 140° F* Nominal capacity @ 45 psi 8 gpm Nominal capacity @ 60 psi 11.5 gpm Safety stop 100° F Maximum output temperature 110° F** ½” NPT connections
*Please know and follow all applicable local plumbing codes when setting the temperature on the water heater. **The high temperature limit stop may be reset to comply with local plumbing codes. See page 11.
2
English
Installation Considerations
For best results, this unit should be installed by a licensed, professional plumber.
• Large pressure differences between the hot and cold supplies should be balanced.
• Before beginning the installation, please read the instructions thoroughly. Inspect the
• product and make sure that all parts are present and in good condition. If you have questions, contact Hansgrohe Technical Services.
ThermoBalance II rough 06623000 does not include service stops. If service stops are
• required by local plumbing code, order the stops separately (part #06900300) or order ThermoBalance II rough 06627000, which incorporates service stops.
The ThermoBalance II is intended for use in a two-function shower. DO NOT plug any
outlet.
The ThermoBalance II rough must be used with a ThermoBalance II trim kit. Do not at-
• tempt to use with any other trim kit.
Do not attempt to use this valve in combination with a diverter tub spout.
Installation Suggestions
ok! ok!
no!
Do not use a diverter tub spout!
Use for a two-feature installation only! Do not plug either outlet!
3
English
Install the ThermoBalance II Rough
Caution: Turn the water off at the supply before
proceeding.
Both outlets must be plumbed. Do not plug any port.
Install the hot and cold supply lines to the rough. The hot supply must be connected to the hot inlet and the cold supply must be connected to the cold inlet. If the supplies are not connected to the correct inlets, the valve cannot work correctly.
(for the sake of clarity, the plastic installation box is not shown in this illustration.)
If using model 06627000: When connecting the hot and cold supplies, hold the stop steady with a wrench to avoid stop mis-alignment, and break­age of the factory sealed thread compound.
Install both outlet lines.
The valve should be level in all planes. It should be installed so that the outside surface of the finished wall falls between the minimum and maxi­mum lines on the installation box. This will insure that the trim fits properly.
4
When finishing the wall, install the wall material up to the oval installation box.
Do not remove the installation box.
When the trim is installed, the plaster shield portion of the installation box will be trimmed nearly flush to the wall and sealed to provide protection against water damage.
Flush the supply lines using the flushing plug
The installation box includes a flushing plug to permit line flushing and pressure testing before the cartridge and finishing parts are installed. A pressure test of the installed piping should be per­formed before the walls are closed.
The flushing plug permits cold water to flow from the bottom outlet and the hot water through the top outlet.
To flush the lines, install a hose bibb and hose to each outlet line. (Using a hose will permit the water to be directed to a location where it will not cause damage.) Flush the lines for at least 5 minutes.
The porting in the flushing plug prevents cross flow. However, it does not stop the flow of water through the outlets.
English
5
English
These instructions cover these models: Valve trim Shower set only trim C Lever 06064XX0 06082XX0 C Scroll 06065XX0 06083XX0 C Cross 06066XX0 06084XX0 Solaris² E 04147XX0 04150XX0 Allegro² E 04153XX0 04156XX0 Metro² E 04159XX0 04162XX0 Metris S 31317XX1 31324XX1 Focus S 31736XX1 31772XX1 Talis S 32317XX1 32324XX1 Solaris E 06636XX0 06642XX0 Stratos E 06580XX0 06586XX0 Metro E 06656XX0 06662XX0
06064XX0
06066XX0 06065XX0
These trim kits are for use with Thermo­Balance II roughs 06623/06627 only. Do not use with any other rough.
The finished wall must be complete and made watertight before installation of this trim kit.
04147XX0 04153XX0 04159XX0
31317XX1 31736XX1 32317XX1
06636XX0
6
06580XX0 06656XX0
Installation
Turn the water off at the main, or at the stops, before beginning.
Cut the plaster shield so that it extends 1/16” outside the surface of the finished wall.
Seal the wall around the i-box with waterproof sealant.
Failure to seal the wall can lead to possible water damage.
Remove the label. Cut the support arms that connect the flushing plug to the installation box. Remove the flushing plug. Do not discard the screws.
English
Be sure to remove the blue
flushing plug sealing gasket.
Failure to remove the gasket
can result in damage to the cartridge and possible water damage.
Insert the cartridge in the rough. Make sure that the locator tab on the cartridge goes straight into the notch in the rough.
Use the flushing plug screws to connect the cartridge retainer plate to the rough. Tighten the screws evenly, using a manual screwdriver, in a cross-wise pattern. Do not overtighten the screws.
notch
locator tab
7
English
Perform the following test to check for damage to the ceramic plates inside the stop unit.
Failure to correctly perform this test can result in possible water damage.
Turn on the water supplies. Grasp the stop unit portion of the cartridge and turn it.
If there is a leak around the cartridge, turn the supplies off, and remove the cartridge. Confirm that the sealing gasket from the flushing plug was removed.
Reinstall the cartridge. Turn the stop unit. If the unit continues to leak, contact Hansgrohe
Customer Service for a replacement cartridge.
Solaris oval escutcheon only: Install the white spacers on the carrier plate (a). Install two Duotec strips on the spacers (b).
Install the remaining two strips on the back of the escutcheon.
stop unit
a
All other models: Install two Duotec
strips directly on the carrier plate. Install the remaining two strips on the back of the escutcheon.
8
b
Install the carrier plate gasket and carrier plate with the carrier plate screws.
Press the escutcheon very firmly over the carrier plate, so that the strips of Duotec interlock, produc­ing a very firm hold.
Install the handle: Tighten the handle screw, using a 3 mm Allen wrench. For proper operation of the valve, the handle screw must engage the slot milled into the brass on the cartridge.
Set the high temperature limit stop (optional) -- see page 11.
Justify the handle.
Justify the Handle
Tools required: Thermometer 3 mm Allen wrench (included with trim kit)
Turn the valve on. Place the thermometer in the water stream.
Turn the temperature control knob until the water coming out measures 100° on the thermometer.
Turn the water off using the lever part of the handle.
Use the 3 mm Allen wrench to loosen the set screw on the bottom of the handle. Remove the handle from the valve (1).
English
Hold the lever in one hand. With the other hand, turn the temperature control knob approximately ½ turn clockwise (2a). Then, without pressing inward on it, turn it counter-clockwise until it is positioned vertically and hits the safety stop (2b).
Reinstall the handle and tighten the set screw (3).
2
a
b
9
Loading...