This symbol indicates that there are important operating and maintenance instructions in the
literature accompanying this unit. Read, Keep and Follow all instructions.
Prior to installation and use of this product, observe the following warnings.
1. Installation and servicing should only be carried out by qualified service personnel and
2. It is essential that provision is made for overload, short circuit and earth fault protection
3. A readily accessible disconnection device shall be incorporated in the electrical
4. Only use tools and replacement parts supplied or recommended by EATON.
5. Care must be taken to ensure selection of suitable cables connecting to these units,
6. The equipment is designed to satisfy the requirements of UL60065 7
7. Be aware that aggressive substances may require extra protection of the equipment to
8. The equipment may need additional means of protection if it is to be installed in
9. Any repairs or replacement parts must be done by the manufacturer or a suitably
10. Due to the large weight of the units, correct planning and equipment must be used
11. Systems can be fitted with integral Fibre Optic transmitters, this means that the fibre
NFPA 70 500.8 (F)
12. When batteries are fitted to electronic equipment they must be removed and are not to
13. After installation, operatives must adhere to the following warning on the units label:
This symbol indicates that dangerous voltage constituting a risk of electric shock may be present
within this unit.
14. Illuminator “CAUTION Possibly hazardous optical radiation emitted from this product.”
1.1 Important Safeguards and Warnings
in accordance with all local/national codes of practice and standards e.g. UL1203
Edn.5, NFPA 70 no modification to the certified product allowed.
for this equipment. Therefore we recommend that a double pole, mains rated,
miniature circuit breaker rated to the max power consumption of the unit, must be
incorporated in the electrical installation of the power supply to this product.
installation wiring, to provide all pole isolation of the supply to the equipment.
This unit does not contain any user serviceable parts.
when installed in operating temperatures above +70°C.
th
Edition
2013/07/24. CSA C22.2 No. 60065-03 2012/08/01 Safety Requirements ANNEX II of
ATEX directive 94/9/EC.
maintain its integrity and explosion protection.
locations where it may be exposed to excessive external stresses e.g. vibration, heat,
impact and damage.
qualified repair agent.
when unpacking and installing also for the P&T units the correct lifting points must be
adhered to (see section 3.1.2)
optic cabling used has additional protective measures to ensure that the optical
radiation is confined within the cabling, by the use of a robust conduit covering
externally, and Kevlar braided cable inside the conduit and the enclosure.
The 2400 & 1400 series camera assemblies have been developed to meet the rigorous
requirements of Flame proof and dust-ignition-proof electrical equipment for installation and use
in hazardous locations found in the onshore and offshore, oil & gas and petro-chemical
installations. The units may also be used in marine and industrial hazardous environments.
The housing body and all external parts are manufactured entirely of AISI 316L stainless steel for
low maintenance and protection from corrosion.
Each of the main end covers is fixed to the body by five (5), M6 x 16-mm stainless steel hex cap
screws, with the cable entry cover of the XP and XT systems using five M5 x 12-mm stainless
steel hex cap screws or M110x1.5 screw on cover; all conforming to the requirements of UL 1203
The weatherproof seal of the union between the body and end covers is maintained by use of ‘O’
ring seals fitted in purpose made grooves.
The camera housings feature an internal sliding camera mounting rail which is fitted with an
internal heating element/de-mister, thermostatically controlled, to maintain operating
temperature, and ensure clarity of vision through the window, together with the optional
integral window wiper mechanism.
The viewing window is made with toughened glass, or in the case of the Thermal Imager and
Dual Imager versions, is made from Infra red transparent material and which is factory fitted with
a mechanical window guard.
The mechanical thermal window guard MUST not be removed.
There are four system types that are made up from different combinations of the 2400 and 1400
series certified units; these are:
XF series, fixed camera housings.
XC series, P&T units with integral tilt shaft only.
XP series, P&T units with integral pan and tilt shafts and a fixed base section for cable
connection.
XT series, P&T units with integral pan and tilt shafts and a fixed base section for cable
connection, also a secondary housing for integrated illuminator.
The XF series fixed housings comprise a single tube section with either 3 cable entries in the rear
cover or 1 in the side (model dependant).
The XC series comprise a camera housing fixed to a P&T unit via an integrated tilt shaft; there are
3 cable entries in the rear cover of the housing or 1 into the blank side of the T unit (model
dependant).
The XP and XT units have dual cable entries into the fixed base section, this prevents any trailing
cables.
The 2400 & 1400 series housings and integrated pan/tilt units have been designed and certified
to UL1203, with the following rating:
Class I Div 1 Group B,C,D
Class II Div 1 Groups E,F,G
T4 T135°C IP66/67
Note: T class and ambient temperature, is dependent on the assembly configuration and
maximum internal power dissipation.
*=T class
## = Ambient Temperature range
The project requirements and unit certification label must be checked by the installer before
installation, to confirm that the product supplied is suitable for the intended installation zone
and environment.
Manufactured in accordance with
There are various camera configurations available within the range; these include Day/Night
cameras with optional wiper, integral washer or external washer, Thermal Imager and Dual
Camera Day/Night and Thermal units.
The range also includes options for Standard Analogue Video and Data, HD IP cameras, Hybrid IP
encoders, Digital Fibre optic convertors and Media convertors.
Due to the large variations of possible configurations, this manual only covers the standard
installation of the units.
For detailed connection and configuration of units, the installer should refer to individual project
specific drawings and information.
In addition to this manual there are various addendums available that cover the specific function
of electronics that can be included within the camera assemblies.
2.2 Supplied Equipment
Contained in the package are the following items:
Camera system
Installation/Technical Manual
Optional Sunshield and Fixings
Optional Washer Nozzle Kit
2.4 Recommended Tools
For installation and maintenance purposes, we recommend the following hand tools:
Voltmeter/Ohmmeter
Torque wrench kit Set to 7.5Nm, Hex Allen wrench bits of 5, 4, 3 & 1.5mm
Spanners 5.5mm, 8mm, 10mm & 13mm A/F
Screw drivers standard and Phillips head
Pliers side cutting and long nose
2.5 Recommended Spares
For Maintenance purposes, we recommend the following spares:
PTZ Seal Kit: O Ring seal kit, spare M6 x 16 & M3 x 6 screws PX99902901
Wiper Assembly (for systems with integrated wiper) PX99902849
XP40 Washer Nozzle (for systems with optional washer system) PX99902864
XP26 Washer Nozzle (for systems with optional washer system) PX99902848
XF Fixed Washer Nozzle (for systems with optional washer system) PX99902865