Axis XP40-Q1942 Installation and maintenance instructions

OXALIS
Unit B, Sutton Parkway, Oddicroft Lane Sutton in Ashfield NG17 5FB, United Kingdom
Class I Div 1 Group B,C,D
Class II Div 1 Groups E,F,G
Class I Zone 1 IIB +Hydrogen
File No E477542
Whilst every effort has been made to ensure that all information in this document is correct at the time of
publication, due to our policy of continuous improvement, the company reserves the right to change any
information contained herein without notice.
2400 & 1400 Series (XP, XT, XC & XF)
Flame Proof Camera Housings
& Pan Tilt Units
Installation & Maintenance Instructions
This manual should be read before attempting to connect or operate the equipment.
This manual should be kept for future reference.
This equipment shall be installed in accordance with the latest local/national codes of practice, and standards
eg :- UL 1203 Edn. 5, CSA22.2 No30-M1986 Edn1 reaffirmed 2012, CSA C22.2 No25-1966 reaffirmed 2014,
CSA C22.2 No 60065-03 Edn. 1, UL60065 Edn. 7,
EATON
Installation & Maintenance Instructions
IMI-UL-XF-XC-XP-XT Issue3.doc
© 2016, EATON
Page 2 of 20
Issue
Date
Details of Amendment
1.0
First Issue
2.0
15/11/2016
Updated drawings. Added amendment record
3.0
24/02/2017
Label type update
Amendment Record
EATON
Installation & Maintenance Instructions
IMI-UL-XF-XC-XP-XT Issue3.doc
© 2016, EATON
Page 3 of 20
Section Page
1.0 General 4
1.1 Important Safeguards and Warnings 4
2.0 Description 5
2.1 Versions 6
2.2 Supplied Equipment 6
2.3 Associated Equipment 6
2.4 Recommended Tools 6
2.5 Recommended Spares 6
3.0 Installation 7
3.1 Unpacking and Handling 7
3.1.1 Unpacking 7
3.1.2 Handling 7
3.2 Mounting 7
3.2.1 Mounting the XP & XT Series 7
3.2.2 Mounting the XC Series 7
3.2.3 Mounting the XF Series 10
3.3 Accessory Installation 11
3.3.1 Sunshield Installation 11
3.3.2 Washer Nozzle Installation 12
3.4 Electrical Installation 13
3.4.1 Electrical Installation XP & XT Integrated Pan, Tilt, housing assembly 13
3.4.2 XP & XT Common Connection Examples 15
3.4.3 Electrical Installation XF & XC Series units 16
3.4.4 XC & XF Common Connection Examples 17
4.0 Maintenance 18
4.1 Corrosion Protection 18
5.0 Labelling 19
5.1 Camera Housing label 19
5.2 Pan Tilt unit label 19
5.3 Pan Tilt unit label 19
6.0 Specifications, Technical data 20
Before Installation of the equipment ensure that:
1 The installation instructions are read and understood 2 The correct tools are available for use when installing
EATON
Installation & Maintenance Instructions
IMI-UL-XF-XC-XP-XT Issue3.doc
© 2016, EATON
Page 4 of 20
1.0 General
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. Read, Keep and Follow all instructions. Prior to installation and use of this product, observe the following warnings.
1. Installation and servicing should only be carried out by qualified service personnel and
2. It is essential that provision is made for overload, short circuit and earth fault protection
3. A readily accessible disconnection device shall be incorporated in the electrical
4. Only use tools and replacement parts supplied or recommended by EATON.
5. Care must be taken to ensure selection of suitable cables connecting to these units,
6. The equipment is designed to satisfy the requirements of UL60065 7
7. Be aware that aggressive substances may require extra protection of the equipment to
8. The equipment may need additional means of protection if it is to be installed in
9. Any repairs or replacement parts must be done by the manufacturer or a suitably
10. Due to the large weight of the units, correct planning and equipment must be used
11. Systems can be fitted with integral Fibre Optic transmitters, this means that the fibre
NFPA 70 500.8 (F)
12. When batteries are fitted to electronic equipment they must be removed and are not to
13. After installation, operatives must adhere to the following warning on the units label:
This symbol indicates that dangerous voltage constituting a risk of electric shock may be present within this unit.
14. Illuminator “CAUTION Possibly hazardous optical radiation emitted from this product.”
1.1 Important Safeguards and Warnings
in accordance with all local/national codes of practice and standards e.g. UL1203 Edn.5, NFPA 70 no modification to the certified product allowed.
for this equipment. Therefore we recommend that a double pole, mains rated, miniature circuit breaker rated to the max power consumption of the unit, must be incorporated in the electrical installation of the power supply to this product.
installation wiring, to provide all pole isolation of the supply to the equipment.
This unit does not contain any user serviceable parts.
when installed in operating temperatures above +70°C.
th
Edition 2013/07/24. CSA C22.2 No. 60065-03 2012/08/01 Safety Requirements ANNEX II of ATEX directive 94/9/EC.
maintain its integrity and explosion protection.
locations where it may be exposed to excessive external stresses e.g. vibration, heat, impact and damage.
qualified repair agent.
when unpacking and installing also for the P&T units the correct lifting points must be adhered to (see section 3.1.2)
optic cabling used has additional protective measures to ensure that the optical radiation is confined within the cabling, by the use of a robust conduit covering externally, and Kevlar braided cable inside the conduit and the enclosure.
be replaced.
WARNING: DO NOT OPEN WHEN ENERGISED OR WHEN
AN EXPLOSIVE ATMOSPHERE IS PRESENT.
CLEAN WITH DAMP CLOTH.
EATON
Installation & Maintenance Instructions
IMI-UL-XF-XC-XP-XT Issue3.doc
© 2016, EATON
Page 5 of 20
2.0 Description
The 2400 & 1400 series camera assemblies have been developed to meet the rigorous requirements of Flame proof and dust-ignition-proof electrical equipment for installation and use in hazardous locations found in the onshore and offshore, oil & gas and petro-chemical installations. The units may also be used in marine and industrial hazardous environments.
The housing body and all external parts are manufactured entirely of AISI 316L stainless steel for low maintenance and protection from corrosion. Each of the main end covers is fixed to the body by five (5), M6 x 16-mm stainless steel hex cap
screws, with the cable entry cover of the XP and XT systems using five M5 x 12-mm stainless
steel hex cap screws or M110x1.5 screw on cover; all conforming to the requirements of UL 1203 The weatherproof seal of the union between the body and end covers is maintained by use of ‘O’ ring seals fitted in purpose made grooves.
The camera housings feature an internal sliding camera mounting rail which is fitted with an internal heating element/de-mister, thermostatically controlled, to maintain operating temperature, and ensure clarity of vision through the window, together with the optional integral window wiper mechanism.
The viewing window is made with toughened glass, or in the case of the Thermal Imager and Dual Imager versions, is made from Infra red transparent material and which is factory fitted with a mechanical window guard. The mechanical thermal window guard MUST not be removed.
There are four system types that are made up from different combinations of the 2400 and 1400 series certified units; these are: XF series, fixed camera housings. XC series, P&T units with integral tilt shaft only. XP series, P&T units with integral pan and tilt shafts and a fixed base section for cable connection.
XT series, P&T units with integral pan and tilt shafts and a fixed base section for cable
connection, also a secondary housing for integrated illuminator.
The XF series fixed housings comprise a single tube section with either 3 cable entries in the rear cover or 1 in the side (model dependant). The XC series comprise a camera housing fixed to a P&T unit via an integrated tilt shaft; there are 3 cable entries in the rear cover of the housing or 1 into the blank side of the T unit (model dependant). The XP and XT units have dual cable entries into the fixed base section, this prevents any trailing cables.
The 2400 & 1400 series housings and integrated pan/tilt units have been designed and certified to UL1203, with the following rating:
Class I Div 1 Group B,C,D Class II Div 1 Groups E,F,G T4 T135°C IP66/67 Note: T class and ambient temperature, is dependent on the assembly configuration and maximum internal power dissipation. *=T class ## = Ambient Temperature range
EATON
Installation & Maintenance Instructions
IMI-UL-XF-XC-XP-XT Issue3.doc
© 2016, EATON
Page 6 of 20
2.0 Description (continued)
The project requirements and unit certification label must be checked by the installer before installation, to confirm that the product supplied is suitable for the intended installation zone and environment. Manufactured in accordance with
UL 1203 Edn. 5, CSA22.2 No30-M1986 Edn1 reaffirmed 2012, CSA C22.2 No25-1966 reaffirmed
2014 , CSA C22.2 No 60065-03 Edn. 1, UL60065 Edn. 7,
2.1 Versions
There are various camera configurations available within the range; these include Day/Night cameras with optional wiper, integral washer or external washer, Thermal Imager and Dual Camera Day/Night and Thermal units. The range also includes options for Standard Analogue Video and Data, HD IP cameras, Hybrid IP encoders, Digital Fibre optic convertors and Media convertors. Due to the large variations of possible configurations, this manual only covers the standard installation of the units. For detailed connection and configuration of units, the installer should refer to individual project specific drawings and information. In addition to this manual there are various addendums available that cover the specific function of electronics that can be included within the camera assemblies.
2.2 Supplied Equipment
Contained in the package are the following items:
Camera system Installation/Technical Manual Optional Sunshield and Fixings Optional Washer Nozzle Kit
2.4 Recommended Tools
For installation and maintenance purposes, we recommend the following hand tools:
Voltmeter/Ohmmeter Torque wrench kit Set to 7.5Nm, Hex Allen wrench bits of 5, 4, 3 & 1.5mm Spanners 5.5mm, 8mm, 10mm & 13mm A/F Screw drivers standard and Phillips head Pliers side cutting and long nose
2.5 Recommended Spares
For Maintenance purposes, we recommend the following spares:
PTZ Seal Kit: O Ring seal kit, spare M6 x 16 & M3 x 6 screws PX99902901 Wiper Assembly (for systems with integrated wiper) PX99902849 XP40 Washer Nozzle (for systems with optional washer system) PX99902864 XP26 Washer Nozzle (for systems with optional washer system) PX99902848 XF Fixed Washer Nozzle (for systems with optional washer system) PX99902865