AXIST8344PowerOn/OffPlug
UserManual

AXIST8344PowerOn/OffPlug
TableofContents
Solutionoverview...........................................3
Productoverview...........................................4
HowtoaddadevicetoaZ-WaveNetwork......................5
HowtotesttheZ-Wavedevice................................6
HowtoprogramtheZ-Wavedevice............................7
Troubleshooting............................................9
Specications..............................................10
2

AXIST8344PowerOn/OffPlug
Solutionoverview
Solutionoverview
ThedeviceisZ-Wave®enabledandfullycompatiblewithanyZ-Waveenablednetwork.ThedevicecanbesetupinaZ-Wave
networktocommunicatedirectlywithotherend-devicessuchaslightingcontrollers,ortoreportdirectlytoaZ-Wavecontroller,
suchasAXISM5065PTZNetworkCamera.
3

AXIST8344PowerOn/OffPlug
Productoverview
Productoverview
1.Linkbutton/LEDindicator
2.Pass-throughoutlet
3.Controllableoutlet
4

AXIST8344PowerOn/OffPlug
HowtoaddadevicetoaZ-WaveNetwork
HowtoaddadevicetoaZ-W aveNetwork
Autoinclusion
ThedetectorsupportstheautoinclusionfeaturewhereitwillautomaticallyenterInclusionmodewhenrstpoweredup.
1.PutaZ-Wavecontrollerintoinclusionmode.
2.PlugtheOn/offPlugintoawalloutletnearthedevicetobecontrolled.
3.EnterPINnumberintotheZ-Wavecontroller.ThePINnumbercanbefoundonthedevice.Seewhereintheinstallation
guide.
4.TheinclusionprocessshouldbecompletedwhentheLEDstopsblinking.
5.Performtestbeforeusingthedevice.SeeHowtotesttheZ-WaveDevice.
Manualinclusion
YoucanalsochoosetomanuallyaddtheZ-Wavedevicetoacontroldevice.Pleasefollowthestepsdescribedbelow.
Note
Formoredetailsseetheinstallationguide
1.Onthefrontsideofthedevice,thereisalink-button/LED-indicatorwhichisusedtosetthedeviceinlearningmode
(inclusion,exclusion).
2.PuttheZ-Wavecontrollerininclusionmode.
3.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
4.EnterPINnumberintotheZ-Wavecontroller.ThePINnumbercanbefoundonthedevice.Seewhereintheinstallation
guide.
5.TheprocessshouldbecompletedwhentheLEDstopsblinking.
6.Performtestbeforeusingthedevice.SeeHowtotesttheZ-WaveDevice.
Manualexclusion
1.PuttheZ-Wavecontrollerinexclusionmode.
2.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintolearning(inclusion/exclusion)mode.
3.TheprocessshouldbecompletedwhentheLEDstopsblinking.
5

AXIST8344PowerOn/OffPlug
HowtotesttheZ-Wavedevice
HowtotesttheZ-Wavedevice
FromtheZ-WaveController’sinterface,turnonthenewlyaddedOn/Offplug(refertotheController’susermanualforinstructions).
TheLEDindicatorontheOn/Offplugshouldlightup.
•TurnofftheOn/Offplugbeforeconnectinganyappliancetoit.
6

AXIST8344PowerOn/OffPlug
HowtoprogramtheZ-Wavedevice
HowtoprogramtheZ-Wavedevice
Note
ProgrammingZ-WavedevicesusingaZ-Wavecontrollerisrecommendedforexperiencedusersonly.
Z-WaveGroup
ThedetectorsupportseitheroneoftwoZ-WaveAssociationGroups:
Group1:Associationwith1Controllernode.
Group2:Associationwith4nodes(i.e.enddevicessuchassmartplugsandotherlightingcontrollers).Thisallowsthedetectorto
transfercommandsdirectlytoenddeviceswithouttheparticipationofthecontroller.Thishastheeffectthatwhenthedetector
triggers,alldevicesassociatedwithdetectorwillbeoperated.
Note
Association-groupsupportcanvaryamongZ-WaveControllers.TheAXISM5065supportsZ-WaveAssociationGroup1.
Group1commands:
•IfthedevicealreadyisapartofaZ-Wavenetworkwhenpoweredup,thedevicewillsendaNoticationReportto
thenodeinGroup1.
•Whensettingupthedeviceorchangingthedevice’sstatus,thedevicewillsendaBinarySwitchReporttothenodeof
Group1.WhenthedeviceisturnedOFF:SwitchBinaryReportValue=0x00.WhenthedeviceisturnedON:Switch
BinaryReportValue=0xFF.
•DeviceReset:WhenperformingFactoryReset,thedevicewillsendDeviceResetLocallyNoticationtothenodeofGroup1.
Group2commands:
•Whenthebuttononthedeviceispressed,thedevicewillsendaBasicSetcommandtothenodesofGroup2.Whenthe
deviceisturnedOFF:BasicSetValue=0x00.WhentheunitisturnedON:BasicSetValue=0xFF
Z-WavePlus® ®®info
RoletypeNodetypeInstallerIconUserIcon
SecondaryAlwaysOn
Version
Protocollibrary
Protocolversion
Manufacturer
ManufacturerID
0x03640x00040x0001
AGI(AssociationGroupInformation)table
Z-WavePlusnode
OnOffPowerSwitchOnOffPowerSwitch
3
4.6(6.7 1.00)
ProductTypeProductID
7

AXIST8344PowerOn/OffPlug
HowtoprogramtheZ-Wavedevice
GroupProleCommandClass&Command
1
2
Basic
BasicGet:Inquireaboutthestatusofthedevice.
•BasicReport:Reportthestatusofthedevice.
•BasicSet:Setthestatusofthedevice.
Notication
Thedevicewillsendnotications(NoticationType=0x08,Event=0x01)uponbeingpoweredon.
Conguration
Thecongurablevaluesareasfollowing:
Rememberthelaststatus:
ParameterNumber
3
GeneralBinarySwitchReport
ControlBasicSet
Size
1
RangeDefault
1/0
1:remember(0:donotremember)
(List)Nbytes
NoticationReport
DeviceResetLocallyNotication
GroupName(UTF-8)
Lifeline
On/Offcontrol(Button1)
Commandclasses
•COMMAND_CLASS_ZWAVEPLUS_INFO_V2
•COMMAND_CLASS_SWITCH_BINARY
•COMMAND_CLASS_SWITCH_ALL
•COMMAND_CLASS_ASSOCIATION_V2
•COMMAND_CLASS_ASSOCIATION_GRP_INFO
•COMMAND_CLASS_TRANSPORT_SERVICE_V2
•COMMAND_CLASS_VERSION_V2
•COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
•COMMAND_CLASS_DEVICE_RESET_LOCALLY
•COMMAND_CLASS_POWERLEVEL
•COMMAND_CLASS_SECURITY
•COMMAND_CLASS_SECURITY_2
•COMMAND_CLASS_NOTIFICATION_V4
•COMMAND_CLASS_CONFIGURATION_V2
•COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
•COMMAND_CLASS_SUPERVISION
8

AXIST8344PowerOn/OffPlug
Troubleshooting
Troubleshooting
Ifyoucan’tndwhatyou’relookingforhere,trythetroubleshootingsectionataxis.com/support.
Action/Status
No
nodeID
Status
Factory
Reset
(This
procedure
should
onlybe
used
when
the
controller
isinoperable.)
øFailureorsuccessinincluding/excludingtheIDcanbeviewedontheZ-WaveController.
Tablebelowliststypicalproblemsencountered:
SymptomCauseofFailure
ThedeviceisnotworkingandLEDisalwaysoffeven
whenbuttonispressed
Thedevice’sLEDturnson,butconnectedappliance
doesnotturnon.
DescriptionLED
TheZ-WavecontrollercouldnotndthedeviceanddidnotprovideanodeID.2-second
1.Pressthelinkbutton3timeswithin1.5secondstoputtheunitintoexclusionmode.
2.Within1secondofstep1,pressandholdthebuttonfor5seconds.
3.NodeIDisdeleted.Thedevicerevertstofactorydefaultstate.
Thedeviceisnotpluggedintotheelectrical
outletproperly
•Theconnectedappliancehas
itsownpowerswitchsettooff.
•Theappliancerequiresa
separateremotecontroltoturn.
indication
on,
2-second
off.
2-second
on,
2-second
off.
Recommendation
Checkpowerconnectionsto
thedevice.
•SettheON/OFF
switchofthe
applianceitself
toONposition
•Appliances
turnedon/off
bywithremote
controlcannot
becontrolledby
thisOn/Offplug
module.
Note
Forbestresults,excludethedevicebeforestartingtheinclusionprocess.Formoredetailsseetheinstallationguide.
9

AXIST8344PowerOn/OffPlug
Specifications
Specifications
Tondthelatestversionoftheproduct’sdatasheet,gototheproductpageataxis.comandlocateSupport&Documentation.
Specications
Operatingvoltage
Maximumload
Range
Frequencyrange
FCCID
Specicationsaresubjecttochangewithoutnotice.
*IfthedeviceistobeusedasarepeateritmustbetherstZ-Wavedeviceaddedtothenetwork.
AC100-120V,50/60Hz
1400W(US),1200W(JP)
Upto100meterslineofsight*
908.42MHz(US),922.5MHz(JP)
FU5AN186
10

UserManualVer.M2.2
AXIST8344PowerOn/OffPlug
©AxisCommunicationsAB,2017-2020
Date:September2020
PartNo.T101 170 76