AXIST8331PIRMotionDetectorSeries
UserManual

AboutthisDocument
ThismanualisintendedforadministratorsandusersofAXIST8331PIR
MotionDetectorSeries.Itincludesinstructionsforusingandmanaging
theproductonyournetwork.Laterversionsofthisdocumentwillbe
postedatwww.axis.com
LegalConsiderations
Videoandaudiosurveillancecanberegulatedbylawsthatvaryfrom
countrytocountry.Checkthelawsinyourlocalregionbeforeusing
thisproductforsurveillancepurposes.
Liability
Everycarehasbeentakeninthepreparationofthisdocument.Please
informyourlocalAxisofceofanyinaccuraciesoromissions.Axis
CommunicationsABcannotbeheldresponsibleforanytechnicalor
typographicalerrorsandreservestherighttomakechangestothe
productandmanualswithoutpriornotice.AxisCommunicationsAB
makesnowarrantyofanykindwithregardtothematerialcontained
withinthisdocument,including,butnotlimitedto,theimplied
warrantiesofmerchantabilityandtnessforaparticularpurpose.Axis
CommunicationsABshallnotbeliablenorresponsibleforincidentalor
consequentialdamagesinconnectionwiththefurnishing,performance
oruseofthismaterial.Thisproductisonlytobeusedforitsintended
purpose.
IntellectualPropertyRights
AxisABhasintellectualpropertyrightsrelatingtotechnologyembodied
intheproductdescribedinthisdocument.Inparticular,andwithout
limitation,theseintellectualpropertyrightsmayincludeoneormore
ofthepatentslistedatwww.axis.com/patent.htmandoneormore
additionalpatentsorpendingpatentapplicationsintheUSandother
countries.
EquipmentModications
Thisequipmentmustbeinstalledandusedinstrictaccordancewiththe
instructionsgivenintheuserdocumentation.Thisequipmentcontains
nouser-serviceablecomponents.Unauthorizedequipmentchangesor
modicationswillinvalidateallapplicableregulatorycertications
andapprovals.
TrademarkAcknowledgments
AXISCOMMUNICATIONS,AXIS,ETRAX,ARTPECandVAPIXare
registeredtrademarksortrademarkapplicationsofAxisABinvarious
jurisdictions.Allothercompanynamesandproductsaretrademarksor
registeredtrademarksoftheirrespectivecompanies.
DisposalandRecycling
Whenthisproducthasreachedtheendofitsusefullife,disposeof
itaccordingtolocallawsandregulations.Forinformationabout
yournearestdesignatedcollectionpoint,contactyourlocalauthority
responsibleforwastedisposal.Inaccordancewithlocallegislation,
penaltiesmaybeapplicableforincorrectdisposalofthiswaste.
Europe
ContactInformation
AxisCommunicationsAB
Emdalavägen14
22369Lund
Sweden
Tel:+46462721800
Fax:+4646136130
www.axis.com
Support
Shouldyourequireanytechnicalassistance,pleasecontactyourAxis
reseller.Ifyourquestionscannotbeansweredimmediately,your
resellerwillforwardyourqueriesthroughtheappropriatechannelsto
ensurearapidresponse.IfyouareconnectedtotheInternet,youcan:
•ndanswerstoresolvedproblemsintheFAQdatabase.Search
byproduct,category,orphrase
•reportproblemstoAxissupportstaffbyloggingintoyourprivate
supportarea
•chatwithAxissupportstaff
•visitAxisSupportatwww.axis.com/techsup/
LearnMore!
VisitAxislearningcenterwww.axis.com/academy/forusefultrainings,
webinars,tutorialsandguides.
Thissymbolmeansthattheproductshallnotbedisposedof
togetherwithhouseholdorcommercialwaste.Directive2012/19/EU
onwasteelectricalandelectronicequipment(WEEE)isapplicablein
theEuropeanUnionmemberstates.Topreventpotentialharmto
humanhealthandtheenvironment,theproductmustbedisposed
ofinanapprovedandenvironmentallysaferecyclingprocess.For
informationaboutyournearestdesignatedcollectionpoint,contact
yourlocalauthorityresponsibleforwastedisposal.Businessesshould
contacttheproductsupplierforinformationabouthowtodispose
ofthisproductcorrectly.
ThisproductcomplieswiththerequirementsofDirective2011/65/EUon
therestrictionoftheuseofcertainhazardoussubstancesinelectrical
andelectronicequipment(RoHS).
China
Thisproductcomplieswiththerequirementsofthelegislative
actAdministrationontheControlofPollutionCausedbyElectronic
InformationProducts(ACPEIP).

AXIST8331PIRMotionDetectorSeries
TableofContents
Functions..................................................4
I/OandEventConguration.......................................4
WalkTest......................................................4
MaskingStrips..................................................5
Day/NightModeAdjustment......................................5
LEDswitch.....................................................5
PulseCountSwitch..............................................5
SensitivitySwitch...............................................6
DetectionAreaAdjustment........................................6
VMDandPIR...................................................6
ReferenceMaterial..........................................8
HardwareOverview..............................................8
AXIST8331PIRMotionDetectorSeriesGraphs.......................9
AXIST8331PIRMotionDetectorSeriesTerminalConnections............10
AXIST8331PIRMotionDetectorSeriesSchematics....................11
3

AXIST8331PIRMotionDetectorSeries
Functions
Functions
I/OandEventConguration
BelowtextappliestobothAXIST8331andAXIST8331-E.
ThissectioncontainsinformationofI/OcongurationandEventsontheCamera.Formoreinformationandspecicationsaboutthe
productsI/OandEventfunctionalityseetheproductsUserManualavailableonwww.axis.com
I/OPortConguration
1.GotoSetup–SystemOptions–Ports&Devices–I/OPorts
2.Setport1toInput(default)
3.SetNormalstateistoGroundedcircuit
4.PressSave
Note
•Iftheportisusedinanevent,itisnotpossibletoswitchbetweenInputandOutputuntiltheeventischangedorremoved.
•ItisonlypossibletomanuallysetInputorOutputifthecameraprovidestwoormorecongurableI/Oports.
EventConguration
1.GototheEventssetuppageandselectActionRules.
2.SelectAdd.
3.TypeinanamefortheActionRule.
4.SelectInputSignalfromtheTriggerdrop-downlist.
-SelectDigitalInputPortfromthedrop-downlistbelow.
-Select1or2fromthedrop-downlistbelow.
-MakesureActive:issettoYes.
5.SelectavaluefromtheScheduledrop-downlist(Alwaysisselectedbydefault)ormanuallysetavaluebyselect
Newschedule.
6.SelectanactionfromtheTypedrop-downlist.
7.PressOKinordertosavetheActionRule
TheActionRulewillnowbeinthelistofActionRules.
WalkTest
ItisrecommendedtoperformawalktestafterinstallationtoconrmthatthePIRsensorisworkingproperly.
Beforethetest,makesurethePIRsensorisconguredasbelow:
•SetthephotocelltoDAY(defaultsetting).
•SetthePulsecountswitchtoTEST.
•SettheLEDswitchtoON(defaultsetting).ThisappliestoAXIST8331only.
Afterthewarmupperiodiscompleted(approximately60s),conductawalktestbymovinginthedetectionzoneofthePIRsensor .
TheLEDlightswhenthePIRsensordetectsamovingobject.
4