Axis T8144 User Manual

Page 1
AXIST814460WIndustrialMidspan
UserManual
Page 2
AXIST814460WIndustrialMidspan
TableofContents
Systemoverview............................................3
Productoverview...........................................4
Specications..............................................5
LEDindicators..................................................5
Operatingconditions.............................................5
Troubleshooting............................................7
2
Page 3
AXIST814460WIndustrialMidspan
Systemoverview
Systemoverview
3
Page 4
AXIST814460WIndustrialMidspan
Productoverview
Productoverview
4
Page 5
AXIST814460WIndustrialMidspan
Specifications
Specifications
Tondthelatestversionoftheproduct’sdatasheet,gotoaxis.com>[product]>Support&Documentation.
LEDindicators
Note
SeeLEDlocationsinProductoverviewonpage4.
LED
PWR1
PWR2
ALARM
PoE
Color,status
Off
Green,static
Off
Green,static
Off
Red,staticNopoweravailableonPWR1orPWR2oroneitherinputs.
OffNoremotedeviceconnectedtoDATA&PWROUTport.
Green,blinkingRemotedeviceconnectedtoDATA&PWROUTportbutPoEnegotiation
Green,staticRemotedeviceconnectedtoDATA&PWROUTportandPoEnegotiation
Indication
NopowersourceconnectedtoPWR1input.
PowersourceconnectedtoPWR1input.
NopowersourceconnectedtoPWR2input.
PowersourceconnectedtoPWR2input.
PoweravailableonbothPWR1andPWR2inputs.
hasfailed.
hassucceeded.
Operatingconditions
TemperatureHumidity
-40°Cto75°C(-40°Fto167°F)10–95%RH(non-condensing)
Powerinputandoutput
Inputvoltage
Maximuminputpower72W
Nominaloutputvoltage
Maximumoutputpower (HighPoweroverEthernet)
Ethernetinterface
Note
SeeEthernetportlocationsinProductoverviewonpage4.
20–60VDC
55VDC
60W
5
Page 6
AXIST814460WIndustrialMidspan
Specifications
Function
DATAIN Ethernet10/100/1000Base-T
DATA&PWROUT Ethernet10/100/1000Base-T,55VDC
Connectors
6-pinDCpowerandalarmterminalconnector
Note
Seetheconnector’spinarrangementinProductoverviewonpage4.
FunctionPinDescription
PWR2
ALARM
PWR1
1
2
3–4
5
6
Ground0VDC
Powerinfrompowersupply
Relaycontact
Ground0VDC
Powerinfrompowersupply
Specication
RJ45femalesocket
RJ45femalesocket,withDCvoltageonwirepairs 1–2,3–6,4–5and7–8
Specication
20–60VDC
Circuitopen(alarmon) Circuitclosed(alarmoff)
20–60VDC
6
Page 7
AXIST814460WIndustrialMidspan
Troubleshooting
Troubleshooting
SymptomCorrectiveaction
Themidspandoesnotpowerup
Theremotedeviceconnectedtothe midspandoesnotpowerup
Theremotedeviceconnectedtothe midspanpowersupbutthereisno datalink
Verifythatthepowersourcevoltageisbetween20–60VDC,andthatit’sworking.
Verifythattheterminalblockconnectorisproperlyconnected.
Verifythatthepowerinletcableisintact/functional.
VerifythattheremotedeviceisdesignedforPoEoperation.
Verifythattheremotedeviceisconnectedtothemidspan’sDATA&PWROUTportusing astandardSTPCAT5orhigher,straight-wirednetworkcablewithfourpairs.
Ifanexternalpowersplitterisinuse,verifythatitworks.
VerifythatthereisnoshortcircuitonanyofthetwistedpaircablesorRJ45connectors.
Ifpossible,connecttheremotedevicetoadifferentmidspan.
Verifythattheremotedeviceisconnectedtothemidspan’sDATAINportusinga standardSTPCAT5orhigher,straight-wirednetworkcablewithfourpairs.
IfusinganEthernetRJ45cable,verifythatitslengthbetweenthenetworkswitchand theremotedeviceislessthan100m(330ft).
Ifpossibleconnecttheremotedevicetoadifferentmidspan.
7
Page 8
UserManualVer.M1.5 AXIST814460WIndustrialMidspan ©AxisCommunicationsAB,2017
Date:July2017
PartNo.1743994
Loading...