Axis T8124-E, T8123-E User Manual

Installation Guide
AXIS T8123-E Outdoor Midspan 30 W (1-port) AXIS T8124-E Outdoor Midspan 60 W (1-port)
ENGLISH DEUTSCH
FRAN
Ç AIS
ITALIANO
ESPAÑOL
Japan -
この装置は、クラスB 情報技術装置です。 この装置は、家庭環境で使用することを目 的として いますが、この装置がラジオやテレビジョン受信機 に近接して使用されると、 受信障害を引き起こすこ とがあります。 取扱説明書に従って正しい取り扱い をして下さい。
Korea -
ࢇЕɼࢽࡈ%ࢷ࢕ળࢶଢԻ۰
࣯Իɼࢽ߾۰یࡈଜЕʨࡶּࢶࡳԻଜֲֻҘ ࠇ߾۰یࡈଟܹ࢑ݡТЬ
Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before using this product for surveillance purposes.
Electromagnetic Compatibility (EMC)
This equipment has been designed and tested to fulfill applicable standards for:
• Radio frequency emission when installed according to the instructions and used in its intended environment.
• Immunity to electrical and electromagnetic phenomena when installed according to the instructions and used in its intended environment.
USA - This equipment has been tested using a shielded
network cable (STP) and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Canada - This Class B digital apparatus complies with
Canadian ICES-003.
Europe - This digital equipment fulfills the
requirements for RF emission according to the Class B limit of EN 55022.
Australia - This digital equipment fulfills the
requirements for RF emission according to the Class B limit of AS/NZS CISPR 22.
Safety
This product complies with IEC/EN/UL 60950-1 and IEC/EN/UL 60950-22, Safety of Information Technology Equipment.
Equipment Modifications
This equipment must be installed and used in strict accordance with the instructions given in the user documentation. This equipment contains no user-serviceable components. Unauthorized equipment changes or modifications will invalidate all applicable regulatory certifications and approvals.
Liability
Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis Communications AB cannot be held responsible for any technical or typographical errors and reserves the right to make changes to the product and documentation without prior notice. Axis Communications AB makes no warranty of any kind with regard to the material contained within this document, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Axis Communications AB shall not be liable nor responsible for incidental or consequential damages in connection with the furnishing, performance or use of this material. This product is only to be used for its intended purpose.
RoHS
This product complies with both the European RoHS directive, 2002/95/EC, and the Chinese RoHS regulations, ACPEIP.
WEEE Directive
The European Union has enacted a Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE Directive). This directive is applicable in the European Union member states. The WEEE marking on this product (see right) or its documentation indicates that the product must not be disposed of together with household waste. To prevent possible harm to human health and/or the environment, the product must be disposed of in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the product supplier, or the local authority responsible for waste disposal in your area. Business users should contact the product supplier for information on how to dispose of this product correctly. This product should not be mixed with other commercial waste.
Support
Should you require any technical assistance, please contact your Axis reseller. If your questions cannot be answered immediately, your reseller will forward your queries through the appropriate channels to ensure a rapid response. If you are connected to the Internet, you can:
• download user documentation and software updates
• find answers to resolved problems in the FAQ database. Search by product, category, or phrase
• report problems to Axis support staff by logging in to your private support area
• chat with Axis support staff (selected countries only)
• visit Axis Support at www.axis.com/techsup/

Safeguards

Store the Axis product in a dry and ventilated environment.
Avoid exposing the Axis product to vibration, shocks or heavy pressure. Do not install the product on unstable brackets, unstable or vibrating surfaces or walls, since this could cause damage to the product.
Only use applicable tools when installing the Axis product; excessive force could cause damage to the prod­uct.
Do not use chemicals, caustic agents, or aerosol cleaners. Use a damp cloth for cleaning.
Use only accessories that comply with technical specification of the product. These can be provided by Axis or a third party.
Installation and removal of AXIS T8123-E/T8124-E must be carried out by qualified personnel only.
The equipment is intended only for installation in a Restricted Access Location.
This product is not intended to become a permanent part of the building structure.
Read this Installation Guide before connecting AXIS T8123-E/T8124-E to its power source.
Follow basic electricity safety measures whenever connecting AXIS T8123-E/T8124-E to its power source.
Power supply cord must not be attached to the building surface nor run through walls, ceilings, floors and similar openings in the building structure.
Measures must be taken to prevent physical damage to the power supply cord, including proper routing.
A voltage mismatch can cause equipment damage and may pose a fire hazard. If the voltage indicated on the label is different from the power outlet voltage, do not connect AXIS T8123-E/T8124-E to this power outlet.
US version only. All wiring and connections shall be in accordance with NFPA 70 (NEC).
US version only. This product is fitted with a NEMA 5-15P plug for connection to the branch circuit. If other attachment methods are required, please reference local codes and requirements for proper connection to the branch circuit.
AXIS T8123-E/T8124-E AC power plug shall be connected to a sealed box in order to meet EN 60529 level IP66 and NEMA 250 level 4x.
AXIS T8123-E/T8124-E AC power lines shall be connected to the socket-outlet, which shall be installed near the equipment and easily accessible.
International version only. AXIS T8123-E/T8124-E AC power lines shall be connected via an external 2-pole circuit breaker to the normal building installation wiring.
ENGLISH
AXIS T8123-E/T8124-E "DATA IN" and "DATA PWR OUT" ports are shielded RJ45 data sockets. They cannot be used as Plain Old Telephone Service (POTS) sockets. Only RJ45 data connectors can be connected to these sockets.
Ensure cable length from Ethernet network source does not exceed 100 m (333 ft). AXIS T8123-E/T8124-E is not a repeater and does not amplify the Ethernet data signal.
Use a splitter if desired, ensure that the splitter is connected close to the terminal and not on the Midspan.
Designed to meet GR-1089-CORE lightning protection demands.
This Axis product shall be used in compliance with local laws and regulations.
Do not attempt to repair the product by yourself, contact Axis or your Axis reseller for service matters
Installation and removal of AXIS T8123-E/T8124-E must be carried out by qualified personnel only.

AXIS T8123-E/T8124-E Installation Guide Page 5

AXIS T8123-E/T8124-E
Installation Guide

Package Contents

AXIS T8123-E/T8124-E
Midspan with pre-installed power cable (power cable country specific)
Mounting kit 2X RJ45 male plug waterproof
Printed material Installation Guide (this document)
Note: Ethernet cable, RJ45 male connectors and mounting screws are not part of the delivery
AC power cable color code Line Neutral Protective earth
US version - NFPA 70 (NEC) Black White Green
International version - IEC 60445 Brown Blue Green/Yellow
International USA
connectors covers Grounding wire

Functions and Features

AXIS T8123-E/T8124-E 1-Port 802.3at Gigabit PoE Outdoor Midspan injects power over data carrying Ethernet cabling. It maintains IEEE802.3at and IEEE802.3af standards. These power levels allow usage by a new range of Ethernet-based applications such as video phones, 802.11n Access Points, WiMAX Transmitters, PTZ cameras and more. AXIS T8123-E/T8124-E DATA PWR OUT port is designed to carry Gigabit Ethernet data and power over a standard CAT5e cable, delivered through 4-pairs (Alt A: pins 1,2(-) / 3,6(+) and Alt B: pins 4,5(+) / 7,8(-)).
ENGLISH
Page 6 AXIS T8123-E/T8124-E Installation Guide
46.36
196
Fig 1
Fig 1b
1
EARTH GROUND
2 3

Install the Hardware

AXIS T8123-E/T8124-E may be wall or bench mounted using the rear side holes.
Note the following before mounting AXIS T8123-E/T8124-E to a fixed location:
• Do not cover AXIS T8123-E/T8124-E or block the airflow to the product with any foreign object. Keep AXIS T8123-E/T8124-E away from excessive heat and humidity, and free from vibration and dust.
• Ensure that the cable length from the Ethernet network source to your Axis video product does not exceed 100 meters (333 ft). AXIS T8123-E/T8124-E is not a repeater and does not amplify the Ethernet data signal.
• There is no "on-off" switch; simply plug AXIS T8123-E/T8124-E into an AC power outlet installed near the equipment and easily accessible. For the international version of AXIS T8123-E/T8124-E AC power line shall also be connected via an external 2-pole circuit breaker to the normal building installation wiring.
To mount:
1. Fasten AXIS T8123-E/T8124-E with three screws. See Fig 1 (screw holes are marked 1, 2 and 3).
2. Connect one end of the grounding wire to EARTH GROUND (see fig 1b) and the other end to an appropriate ground location. Make sure that this step (2) is performed before connecting AXIS T8123-E/T8124-E to its power source! Use the supplied ground wire or a wire of equal or larger area.
Note: When mounting the AXIS T8123-E/T8124-E make sure to use appropriate screws and plugs
for the surface (wood, concrete etc.). Do not unscrew the four pre-mounted screws located in every corner of the product, since this violate the warranty of the product.
AXIS T8123-E/T8124-E Installation Guide Page 7
DATA IN
DATA PWR OUT
LINE AC
Fig 2
Fig 3
RJ45 male plug
A
B
C
RJ45 male plug waterproof connector cover
Fig 4
INCOMING MAINS VOLTAGE
EXTERNAL PROTECTIVE GROUND WIRE
3. Thread male plug waterproof connector cover (A,B and C) on to the Ethernet cable. See Fig 3.
4. Attach the Ethernet cable to DATA IN. See Fig 2.
5. Thread plug (A) over the RJ45 male plug, connected to DATA IN. See Fig 3.
6. Thread housing (B) over the plug and screw (hand tight only). See Fig 3.
7. Thread cover (C) over the connector and screw (hand tight only). See Fig 3.
8. Repeat steps 2 to 6 for DATA PWR OUT.
9. Connect AXIS T8123-E/T8124-E to an AC power line (100-240 V AC) complying with the information in the Safeguards.
International version only. See Fig 4.
Note: Do not use cross over cable between AXIS T8123-E/T8124-E output port and load device.
ENGLISH
L
N
NPEL
PE
Page 8 AXIS T8123-E/T8124-E Installation Guide

Specifications

Environmental
Mode Temperature Relative humidity IP Class
Operating AXIS T8123-E
Operating AXIS T8124-E
Storage -40°C to 85°C (-40°F to 185°F) Max 95%
Electrical
Input Voltage 100-240 V AC (50/60 Hz)
Input Current AXIS T8123-E 1 Ampere (max)
Input Current AXIS T8124-E 2 Ampere (max)
Available Output Power (max) AXIS T8123-E 30 Watt
Available Output Power (max) AXIS T8124-E 60 Watt
Nominal Output Voltage 55 V DC
-40°C to 50°C for 30 Watts (-40°F to 131°F)
-40°C to 65°C for 15.4 Watts (-40°F to149°F)
-40°C to 50°C for 60 Watts (-40°F to 131°F)
-40°C to 65°C for 30 Watts (-40°F to 149°F)
10 to 100% (condensing) IP66
N/A
(non-condensing)
Interface
Input (DATA IN): Ethernet 10/100/1000Base-T
Output (DATA PWR OUT): Ethernet 10/100/1000Base-T, plus 55 V DC
Power Cable (LINE AC) Pre-installed 3m power cable
AC power cable color code Line Neutral Protective earth
US version - NFPA 70 (NEC) Black White Green
International version - IEC 60445 Brown Blue Green/Yellow
RJ45 female socket
RJ45 female socket, with DC voltage on wire pairs 1-2 & 3-6, 4-5 & 7-8.
AXIS T8123-E/T8124-E Installation Guide Page 9

Troubleshooting

Symptom Corrective Steps
AXIS T8123-E/ T8124-E does not power up
A port indicator on the powered device is not lit and the device does not operate
The end device operates, but there is no data link
1. Verify a reliable power cord is used.
2. Verify voltage at the power inlet is between 100-240 V AC.
3. Remove and reapply power and check the indicators on the powered device during power up sequence.
1. Verify the Midspan detects a device.
2. Verify that the device is designed for PoE operation
3. Verify you are using a standard Category 5/5e/6, straight-wired cable, with four pairs.
4. If an external power splitter is in use, replace it with a known good splitter
5. Ensure input Ethernet cable is connected to the DATA IN port.
6. Verify that the device is connected to the DATA PWR OUT port.
7. Try to reconnect the same powered device into a different Midspan. If it works, there is probably a faulty port or RJ45 connection.
8. Verify there is no short over any of the twisted pair cables or over the RJ45 connectors.
1. Verify the port indicator on the powered device is continuously lit.
2. If an external power splitter is in use, replace it with a known-good splitter.
3. Verify that for this link, you are using standard UTP/FTP Category 5 straight (non-crossover) cabling, with all four pairs.
4. Verify Ethernet cable length is less than 100 meters from Ethernet source to load/remote terminal.
5. Try to reconnect the same powered device into a different Midspan. If it works, there is probably a faulty port or RJ45 connection.
ENGLISH

Warranty

For information about Axis product warranty and thereto related information, see www.axis.com/warranty
Dispositifs de protection
Conserver ce produit Axis dans un environnement sec et ventilé.
Ne pas exposer ce produit Axis aux vibrations, aux chocs ou au fortes pressions. Ne pas installer ce produit sur des supports, surfaces ou murs instables ou soumis aux vibrations car cela pourrait endommager le produit.
Lors de l'installation du produit Axis, n'utiliser que les outils appropriés; éviter d'appliquer une force excessive car cela pourrait endommager le produit.
Ne pas utiliser de produits chimiques, de substances caustiques ou de nettoyants pressurisés. Nettoyer à l'aide d'un tissu humide.
Utiliser uniquement des accessoires compatibles aux spécifications techniques du produit. Ils peuvent être fournis par Axis ou un tiers.
Le montage et le démontage de l'AXIS T8123-E/T8124-E doivent être réalisés par un personnel qualifié uniquement.
L'équipement est uniquement destiné à l'installation dans un Emplacement à Accès Restreint.
Ce produit n'est pas destiné à s'intégrer à la structure du bâtiment de façon permanente.
Consulter le Guide d'installation avant de raccorder l'AXIS T8123-E/T8124-E à sa source électrique.
Suivre les mesures de sécurité électrique de base lors de chaque raccordement de l'AXIS T8123-E/T8124-E à sa source électrique.
Le cordon d'alimentation ne doit pas être raccordé à la surface du bâtiment ni acheminé à travers les murs, les plafonds, les planchers et d'autres ouvertures similaires dans la structure du bâtiment.
Des mesures doivent être prises afin d'éviter des dommages physiques au cordon d'alimentation, dont l'acheminement approprié.
Un défaut d'appariement de la tension peut endommager l'équipement et représenter un risque d'incendie. Si la tension indiquée sur l'étiquette est différente de celle de la prise secteur, ne pas raccorder l'AXIS T8123-E/ T8124-E à cette prise secteur.
Version américaine uniquement. Tout le câblage et les branchements doivent se faire conformément à la norme NFPA 70 (NEC).
Version américaine uniquement. Ce produit est équipé d'une prise NEMA 5-15P pour le raccordement au circuit de dérivation. Si d'autres méthodes de fixation sont requises, veiller à se reporter aux réglementations et exigences locales pour un raccordement approprié au circuit de dérivation.
La fiche d'alimentation en alternatif de l'AXIS T8123-E/T8124-E devra être raccordée à une boite scellée afin de se conformer aux normes EN 60529 niveau IP66 et NEMA 250 niveau 4x.
Les lignes électriques en alternatif de l'AXIS T8123-E/T8124-E devront être raccordées à la prise de courant. Celle-ci devra être installée près de l'équipement et facilement accessible.
Version internationale uniquement. Les lignes électriques en alternatif de l'AXIS T8123-E/T8124-E devront être raccordées au câblage normal de l'installation électrique du bâtiment à l'aide d'un sectionneur bipolaire externe.
Les ports "DATA IN" et "DATA PWR OUT" de l'AXIS T8123-E/T8124-E sont des prises de données RJ45 protégées. Elles ne doivent pas être utilisée en tant que prises de services téléphoniques traditionnels (POTS). Seuls les connecteurs de données RJ45 peuvent être connectés à ces prises.
S'assurer que la longueur de câble à partir de la source réseau Ethernet ne dépasse pas 100 m (333 ft). L'AXIS T8123-E/T8124-E n'est pas un répéteur et n'amplifie pas le signal de données Ethernet.
Utiliser un diviseur si nécessaire. S'assurer que le diviseur est raccordé près de la borne et pas sur l'injecteur.
Conçu pour répondre à la norme GR-1089-CORE relative à la protection contre la foudre.
FRAN
Ç AIS
Ce produit Axis doit être utilisé conformément aux lois et dispositions locales en vigueur.
Ne pas essayer de réparer ce produit par vous-même, contacter Axis ou votre revendeur Axis pour l'entretien.
Le montage et le démontage de l'AXIS T8123-E/T8124-E doivent être réalisés par un personnel qualifié uniquement.

AXIS T8123-E/T8124-E Guide d'installation Page 13

AXIS T8123-E/T8124-E
Guide d'installation

Contenu de l’emballage

AXIS T8123-E/T8124-E
Injecteur avec câble d'alimentation pré­installé (câble d'alimentation spécifique au pays)
Kit de montage 2x prises mâles RJ45 étanche
Documentation imprimée Guide d'installation (ce document)
Remarque : Le câble Ethernet, les connecteurs mâles RJ45 et les vis de montage ne
font pas partie de la livraison
International États-Unis
Caches de connecteurs Câble de mise à la terre
FRAN
Ç AIS
Code de couleur du câble d'alimentation alternatif
Version américaine - NFPA 70 (NEC) Noir Blanc Vert
Version internationale - IEC 60445 Marron Bleu Vert/Jaune
Ligne Neutre Terre de protection

Fonctions et caractéristiques

L'injecteur PoE d'extérieur AXIS T8123-E/T8124-E 802.3at à un port Gigabit transporte le courant électrique en plus des données en utilisant le câblage Ethernet. Il assure le respect des normes IEEE802.3at et IEEE802.3af. Ces niveaux de puissance permettent une utilisation par une nouvelle gamme d'applications basées sur Ethernet telles que les visiophones, les Points d'Accès 802.11n, les Transmetteurs WiMAX, les caméras PTZ et plus encore. Le port DATA PWR OUT de l'AXIS T8123-E/ T8124-E a été conçu pour transporter des données Ethernet Gigabit et de la puissance par un câble standard CAT5e, fournis par 4-paires (Alt A : fiches 1,2(-) / 3,6(+) et Alt B : fiches 4,5(+) / 7,8(-)).
Page 14 AXIS T8123-E/T8124-E Guide d'installation

L'installation du matériel

L'AXIS T8123-E/T8124-E peut être monté sur un mur ou sur un établi à l'aide des perçages arrière.
Prendre note des informations suivantes avant d'effectuer le montage de l'AXIS T8123-E/T8124-E à l'emplacement définitif :
• Ne pas couvrir l'AXIS T8123-E/T8124-E ou obstruer l'écoulement d'air vers le produit avec un corps étranger. Tenir l'AXIS T8123-E/T8124-E à l'écart de la chaleur et de l'humidité, et exempt de vibrations et de poussières.
• S'assurer que la longueur de câble à partir de la source réseau Ethernet jusqu'à votre produit vidéo Axis ne dépasse pas 100 mètres(333 pieds). L'AXIS T8123-E/T8124-E n'est pas un répéteur et n'amplifie pas le signal de données Ethernet.
• Il n'y a pas d'interrupteur "marche-arrêt". Raccorder simplement l'AXIS T8123-E/T8124-E à une prise électrique en alternatif installée près de l'équipement et facilement accessible. Pour la version internationale de l'AXIS T8123-E/T8124-E, la ligne électrique en alternatif devra être raccordée au câblage normal de l'installation électrique du bâtiment à l'aide d'un sectionneur bipolaire externe.
Pour le montage :
1. Fixer l'AXIS T8123-E/T8124-E à l'aide de trois vis. Voir Fig 1 (les trous de vis sont numérotés 1, 2 et 3).
2. Raccorder une des extrémités du câble de mise à la terre à la PRISE DE TERRE (voir fig 1b) et l'autre extrémité à un emplacement approprié au sol. S'assurer que cette étape (2) est effectuée avant le raccordement de l'AXIS T8123-E/T8124-E à sa source d'alimentation ! Utiliser le conducteur de terre fourni ou un conducteur de même taille ou plus grand.
Remarque :
Lors du montage de l'AXIS T8123-E/T8124-E, s'assurer d'utiliser les vis et les prises appropriées à la surface (bois, béton, etc.). Ne pas dévisser les quatre vis prémontées situées à chaque angle du produit, car cela irait à l'encontre de la garantie du produit.
Loading...
+ 30 hidden pages