Axis T8008 Installation Guide

INSTALLATIONGUIDE
AXIST8008PS12PowerSupply
LegalConsiderations
Videosurveillancecanberegulatedbylawsthatvaryfrom countrytocountry.Checkthelawsinyourlocalregion beforeusingthisproductforsurveillancepurposes.
Liability
Everycarehasbeentakeninthepreparationofthis document.PleaseinformyourlocalAxisofceofany inaccuraciesoromissions.AxisCommunicationsABcannot beheldresponsibleforanytechnicalortypographicalerrors andreservestherighttomakechangestotheproductand manualswithoutpriornotice.AxisCommunicationsAB makesnowarrantyofanykindwithregardtothematerial containedwithinthisdocument,including,butnotlimited to,theimpliedwarrantiesofmerchantabilityandtnessfor aparticularpurpose.AxisCommunicationsABshallnot beliablenorresponsibleforincidentalorconsequential damagesinconnectionwiththefurnishing,performance oruseofthismaterial.Thisproductisonlytobeusedfor itsintendedpurpose.
IntellectualPropertyRights
AxisABhasintellectualpropertyrightsrelatingto technologyembodiedintheproductdescribedinthis document.Inparticular,andwithoutlimitation,these intellectualpropertyrightsmayincludeoneormoreof thepatentslistedatwww.axis.com/patent.htmandoneor moreadditionalpatentsorpendingpatentapplicationsin theUSandothercountries.
Thisproductcontainslicensedthird-partysoftware.See themenuitem“About”intheproduct’suserinterfacefor moreinformation.
ThisproductcontainssourcecodecopyrightAppleCom­puter,Inc.,underthetermsofApplePublicSourceLicense
2.0(seewww.opensource.apple.com/apsl).Thesourcecode isavailablefromhttps://developer.apple.com/bonjour/
EquipmentModications
Thisequipmentmustbeinstalledandusedin strictaccordancewiththeinstructionsgiveninthe userdocumentation.Thisequipmentcontainsno user-serviceablecomponents.Unauthorizedequipment changesormodicationswillinvalidateallapplicable regulatorycerticationsandapprovals.
TrademarkAcknowledgments
AXISCOMMUNICATIONS,AXIS,ETRAX,ARTPECandVAPIX areregisteredtrademarksortrademarkapplicationsofAxis ABinvariousjurisdictions.Allothercompanynamesand productsaretrademarksorregisteredtrademarksoftheir respectivecompanies.
Apple,Boa,Apache,Bonjour,Ethernet,InternetExplorer, Linux,Microsoft,Mozilla,Real,SMPTE,QuickTime,UNIX, Windows,WindowsVistaandWWWareregistered trademarksoftherespectiveholders.Javaandall Java-basedtrademarksandlogosaretrademarksor registeredtrademarksofOracleand/oritsafliates.
TM
UPnP
isacerticationmarkoftheUPnP
Corporation.
TM
Implementers
Support
Shouldyourequireanytechnicalassistance,pleasecontact yourAxisreseller.Ifyourquestionscannotbeanswered immediately,yourresellerwillforwardyourqueriesthrough theappropriatechannelstoensurearapidresponse.Ifyou areconnectedtotheInternet,youcan:
downloaduserdocumentationandsoftwareupdates
ndanswerstoresolvedproblemsintheFAQdatabase.
Searchbyproduct,category,orphrase
reportproblemstoAxissupportstaffbylogginginto
yourprivatesupportarea
chatwithAxissupportstaff(selectedcountriesonly)
visitAxisSupportatwww.axis.com/techsup/
LearnMore!
VisitAxislearningcenterwww.axis.com/academy/for usefultrainings,webinars,tutorialsandguides.
RegulatoryInformation
Europe
ThisproductcomplieswiththeapplicableCEmarking
directivesandharmonizedstandards:
ElectromagneticCompatibility(EMC)Directive
2004/108/EC.SeeElectromagneticCompatibility (EMC),onpage2.
LowVoltage(LVD)Directive2006/95/EC.SeeSafety,
onpage3.
RestrictionsofHazardousSubstances(RoHS)Directive
2011/65/EU.SeeDisposalandRecycling,onpage3. Acopyoftheoriginaldeclarationofconformitymaybe obtainedfromAxisCommunicationsAB.SeeContact Information,onpage3.
ElectromagneticCompatibility(EMC)
Thisequipmenthasbeendesignedandtestedtofulll applicablestandardsfor:
Radiofrequencyemissionwheninstalledaccordingto
theinstructionsandusedinitsintendedenvironment.
Immunitytoelectricalandelectromagneticphenomena
wheninstalledaccordingtotheinstructionsandused
initsintendedenvironment.
USA
Thisequipmenthasbeentestedusingashieldednetwork cable(STP)andfoundtocomplywiththelimitsfora ClassAdigitaldevice,pursuanttopart15oftheFCCRules. Theselimitsaredesignedtoprovidereasonableprotection againstharmfulinterferencewhentheequipmentis operatedinacommercialenvironment.Thisequipment generates,uses,andcanradiateradiofrequencyenergy and,ifnotinstalledandusedinaccordancewiththe instructionmanual,maycauseharmfulinterferenceto radiocommunications.Operationofthisequipmentin aresidentialareaislikelytocauseharmfulinterference inwhichcasetheuserwillberequiredtocorrectthe interferenceathisownexpense.
Canada
ThisClassAdigitalapparatuscomplieswithCanadian ICES-003. CetappareilnumériquedelaclasseAestconfomeàla normeNMB-003duCanada.
Europe
ThisdigitalequipmentfulllstherequirementsforRF emissionaccordingtotheClassAlimitofEN55022. Notice!ThisisaClassAproduct.Inadomesticenvironment thisproductmaycauseRFinterference,inwhichcasethe usermayberequiredtotakeadequatemeasures.
Thisproductfulllstherequirementsforemissionand immunityaccordingtoEN50121-4andIEC62236-4railway applications.
Thisproductfulllstherequirementsforimmunity accordingtoEN61000-6-1residential,commercialand light-industrialenvironments.
Thisproductfulllstherequirementsforimmunity accordingtoEN61000-6-2industrialenvironments.
Thisproductfulllstherequirementsforimmunity accordingtoEN55024ofceandcommercialenvironments
Australia/NewZealand
ThisdigitalequipmentfulllstherequirementsforRF emissionaccordingtotheClassAlimitofAS/NZSCISPR22. Notice!ThisisaClassAproduct.Inadomesticenvironment thisproductmaycauseRFinterference,inwhichcasethe usermayberequiredtotakeadequatemeasures.
Japan
この装置は、クラスA情報技術装置です。この装 置を家庭環境で使用すると電波妨害を引き起こす ことがあります。この場合には使用者が適切な対 策を講ずるよう要求されることがあります。
Safety
ThisproductcomplieswithIEC/EN/UL60950-1,Safetyof InformationTechnologyEquipment.
DisposalandRecycling
Whenthisproducthasreachedtheendofitsusefullife, disposeofitaccordingtolocalrawsandregulations.For informationaboutyournearestdesignatedcollectionpoint, contactyourlocalauthorityresponsibleforwastedisposal. Inaccordancewithlocallegislation,penaltiesmaybe applicableforincorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshallnotbe disposedoftogetherwithhouseholdorcommercialwaste. Directive2012/19/EUonwasteelectricalandelectronic equipment(WEEE)isapplicableintheEuropeanUnion memberstates.Topreventpotentialharmtohumanhealth andtheenvironment,theproductmustbedisposedofin anapprovedandenvironmentallysaferecyclingprocess. Forinformationaboutyournearestdesignatedcollection point,contactyourlocalauthorityresponsibleforwaste disposal.Businessesshouldcontacttheproductsupplierfor informationabouthowtodisposeofthisproductcorrectly.
Thisproductcomplieswiththerequirementsof Directive2011/65/EUontherestrictionoftheuseof certainhazardoussubstancesinelectricalandelectronic equipment(RoHS).
China
Thisproductcomplieswiththerequirementsofthe legislativeactAdministrationontheControlofPollution CausedbyElectronicInformationProducts(ACPEIP).
ContactInformation
AxisCommunicationsAB Emdalavägen14 22369Lund Sweden
Tel:+46462721800 Fax:+4646136130
www.axis.com
AXIST8008PS12PowerSupply
SafetyInformation
ReadthroughthisInstallationGuidecarefullybeforeinstallingtheproduct.KeeptheInstallation Guideforfuturereference.
HazardLevels
DANGER
WARNING
CAUTION
NOTICE
NOTICE NOTICE
Indicatesahazardoussituationwhich,ifnotavoided,willresultin deathorseriousinjury.
Indicatesahazardoussituationwhich,ifnotavoided,couldresult indeathorseriousinjury.
Indicatesahazardoussituationwhich,ifnotavoided,couldresult inminorormoderateinjury.
Indicatesasituationwhich,ifnotavoided,couldresultindamage toproperty.
OtherMessageLevels
ImportantIndicatessignicantinformationwhichisessentialfortheproduct
NoteIndicatesusefulinformationwhichhelpsingettingthemostout
tofunctioncorrectly.
oftheproduct.
5
AXIST8008PS12PowerSupply
SafetyInstructions
WARNING
•TheAxisproductshallbeinstalledbyatrainedprofessional.
NOTICE
NOTICE NOTICE
•TheAxisproductshallbeusedincompliancewithlocallawsandregulations.
•TousetheAxisproductoutdoors,orinsimilarenvironments,itshallbeinstalledinan approvedoutdoorhousing.
•StoretheAxisproductinadryandventilatedenvironment.
•AvoidexposingtheAxisproducttoshocksorheavypressure.
•Donotinstalltheproductonunstablebrackets,surfacesorwalls.
•UseonlyapplicabletoolswheninstallingtheAxisproduct.Excessiveforcecouldcause damagetotheproduct.
•Donotusechemicals,causticagents,oraerosolcleaners.Useacleanclothdampened withpurewaterforcleaning.
•Useonlyaccessoriesthatcomplywithtechnicalspecicationoftheproduct.Thesecanbe providedbyAxisorathirdparty.
•UseonlysparepartsprovidedbyorrecommendedbyAxis.
•Donotattempttorepairtheproductbyyourself.ContactAxissupportoryourAxis resellerforservicematters
Transportation
NOTICE
NOTICE NOTICE
•WhentransportingtheAxisproduct,usetheoriginalpackagingorequivalenttoprevent damagetotheproduct.
6
AXIST8008PS12PowerSupply
InstallationGuide
ThisInstallationGuideprovidesinstructionsforinstallingAXIST8008PS12PowerSupplyina cabinetfromtheAXIST98A-VESurveillanceCabinetSeriestosupplypowertotheQ60-CPTZ DomeNetworkCameras.
InstallationSteps
1.Makesurethepackagecontents,toolsandothermaterialsnecessaryfortheinstallation areinorder.Seepage7.
2.Studythehardwareoverview.Seepage8.
3.Studythespecications.Seepage8.
4.Installthehardware.Seepage9.
PackageContents
•AXIST8008PS12PowerSupply
•Mountingbracket
•Screwkit
•DINrailclip
•InstallationGuide(thisdocument)
RecommendedTools
•TorxscrewdriverT10
•TorxscrewdriverT20
7
AXIST8008PS12PowerSupply
1 2 3
HardwareOverview
1
ACinput
2
Notused
3
DCoutput
Specications
OperatingConditions
ClassicationIIEC60529IP64
Temperature
Humidity
IEC68–2–27 IEC68–2–6/IEC721–3–2
–40°Cto85°C (–40°Fto185°F)
10-100%RH(condensing)
TechnicalSpecications
Inputvoltage
Inputfrequency47–63Hz
Outputvoltage12.5VDC
Outputcurrent
90–264VAC(Operating) 115/230VAC(Nominal)
20A
8
AXIST8008PS12PowerSupply
1
2
3
RatedLoad250Wmaximum
Overvoltagecategory(OVC)
Minimum85Wat75°C Derateoutputpowerfrom45°Cto85°C
II
InstalltheHardware
1.Attachthepowersupplytothemountingbracket.
Note
Usethemountingbracketsuppliedwiththepowersupply.Themountingbracketsupplied withtheAXIST98A-VESurveillanceCabinetcannotbeusedwiththispowersupply.
1
Screw
2
Mountingbracket
3
Powersupply
2.RemovethescrewatoneendoftheDINrailandloosenthescrewattheotherend.
3.InsertthemountingbracketinthecabinetwiththeDINrailrunningthroughit.
DANGER
Riskofelectricshock.TheDINrailneedstorunthroughthemountingbrackettoachieve apropergroundingofthepowersupply.
9
AXIST8008PS12PowerSupply
1 2 3
1
DINrail
2
Screw
3
Mountingbracket
4.Alignthemountingbracketwiththeplasticlugsasshowninthegurebelowand fastenitwiththescrews.
5.FastenthescrewsintheDINrail.
10
AXIST8008PS12PowerSupply
1 12 3 4
1
Plasticlug
2
Mountingbracket
3
Screw
4
Powersupply
6.Connectthepowersupply.Forinformationaboutwiring,seePowerSupplyCables,on page12.
InstallonaDINRail
ThepowersupplycanbeinstalledonaDINrailusingthesuppliedDINclip.
Note
ItisnotpossibletousethismethodtoinstallthepowersupplyinaT98Aseriescabinet.
1.AttachtheDINcliptothemountingbracket.
2.Attachthepowersupplytothemountingbracket.
11
AXIST8008PS12PowerSupply
1
2
3
1
CINclip
2
Mountingbracket
3
Powersupply
PowerSupplyCables
Cable
ACInputCable
DCOutputCable
LengthDesignation
400±10mm (15.7±0.4in.)
400±10mm (15.7±0.4in.)
L=LineBrown
N=NeutralBlue
PE=Protective Earth
+
-
12
WireColorCableArea
Green/Yellow
Blue
Gray
0.8mm (AWG18)
0.8mm (AWG18)
0.8mm (AWG18)
2mm
2mm
2
2
2
2
(AWG14)
2
(AWG14)
AXIST8008PS12PowerSupply
L
N
NPEL
INCOMING MAINS VOLTAGE
EXTERNAL PROTECTIVE GROUND WIRE
AXIS T8008 PS12 POWER SUPPLY
1
2
3
ConnectionDiagram
1
Incomingmainsvoltage
2
Externalprotectivegroundwire
3
AXIST8008PS12PowerSupply
Note
ForuseinanOVCIIIelectricalenvironment,addasurgeprotectorsuchas AXISElectricalSafetyKitA120VACorAXISElectricalSafetyKitB230VAC.
WarrantyInformation
ForinformationaboutAxis’productwarrantyandtheretorelatedinformation,see
www.axis.com/warranty/
13
InstallationGuide AXIST8008PS12PowerSupply ©AxisCommunicationsAB,2013
Ver.M2.2
Date:December2013
PartNo.50951