Fig. 6-1 Axis IP Utility ...................................................................................................... 25
History of revisions
Product: ExCam® XPT Q6075
Title: User Manual for ExCam® XPT Q6075
Doc. -Id. 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx
Author: Steffen Seibert, Grad. Eng.
Created on: 14.05.2020
Doc.-ID: 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx, Page 3 of 28
1
1 Introduction
In the ExCam XPT Q6075 is a powerful IP dome camera of the latest generation, with 2megapixel resolution at 1920x1080p points. It is certified by ATEX, IECEx & EAC-Ex (and
more).
This dome camera can endlessly rotate around its own axis. When tilted, it covers a 180°
area, and the picture is automatically turned around. This is done with a high speed and
precision. Thanks to the Lightfinder-Technology you receive sharp images and superior
details even in demanding light conditions. Not only the excellent light sensitivity makes
this camera that special but also the 40-fold optical zoom produces sharp, precise images
and brilliant wide-angle images.
The ExCam series is certified both in accordance with the European (ATEX) and international directive (IECEx). The explosion-protected housing is approved for the ATEX group
II for zones 1, 2, 21 and 22 including the explosion groups IIC / IIIC. To see other approvals,
please visit our website at www.samcon.eu
In designing the ExCam XPT Q6075, we attached a very high importance to safety, mechanical precision and high quality of stainless steel.
2 Technical data
2.1 Explosion protection
Identification marks
acc. to Directive 2014/34/EU: II 2G (zone 1 and 2)
II 2D (zone 21 and 22)
Explosion protection (gas): Ex db IIC T6 Gb
Explosion protection (dust): Ex tb IIIC T80°C Db
Protection class: IP 68 (IEC /EN 60529)
Transport/storage temperature: 0°C…+40°C
Ambient temperature (EX)1: -50°C…+60°C
Explosion protection-relevant maximum ambient temperature range relevant to explosion protection, deviation from the functional
temperature range, functional temperature range (MTBF)
Doc.-ID: 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx, Page 4 of 28
Named testing laboratory: TÜV Rheinland (number 0035)
EU type approval certificate: TÜV 18 ATEX 8218X
IECEx Certificate of Conformity: IECEx TUR 18.0023X
EAC-Ex TUR Report: RU C-DE.AБ.61.B.00381/19
IA No: MASC MS/18-3256X
Further certification: see https://www.samcon.eu/en/products/network/excam-xpt-q6075
2.2 Electrical parameters of the camera
24VDC Power input:
Permissible temperature range: -50°C < T
< +60°C
amb
Power supply: 24 VDC
Power consumption: approx. 60W@-50°C
(depends on the temperature)
PoE+ Power input:
Permissible temperature range: -0°C < T
< +60°C
amb
Power supply: PoE, IEEE 802.3at class 4
Reference voltage: 48 VDC (44...54 VDC)
Maximum power consumption: 17.1 W
Typical power consumption: 11 W
2.3 Connection cable Ex-d - Ex-e (ASKDP03-T)
Description: Data transfer and power supply of the camera module
(compliant with DIN EN 60079-14),
Jacket colour: green (GN), similar to RAL3001
Outside diameter: 15.50 ± 0.6 mm
Bending radius: 15 x Da when installed and 10 x Da after relocation
Data line: 4 x 2 x AWG23/1 CAT.6a
Performance elements: 3G1.5 (BK-BU-GN/YE)
Properties: PUR halogen-free, flame-retardant,
UV-resistant, chemical resistance, shielded
(see www.samcon.eu)
Doc.-ID: 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx, Page 5 of 28
Camera (Ex-d)
Terminal box (Ex-e)
Permissible ambient temperature
0°C … +60°C
(for PoE+ power supply)
-50°C … +60°C
(at 24 VDC power supply)
-60°C … +55°C
Protection class as per EN
60529/IEC 529
IP68
(Test conditions: 24h/3m
water column 5°C°
IP66
Housing material
- stainless steel, mat. no. 1.4404
- LEXAN
polyester resin
Weight
20 kg
about 1 kg
Dimensions
D195mm x 378mm
145mm x 145mm x 71mm
Fig. 2-1 Sectional view of ASKDP03-T
2.4 Video-technical characteristics
We use the AXIS Q6075 Dome Camera in a pressure-resistant enclosure. For details,
please refer to the Product Documentation, video-technical data of AXIS®:
https://www.axis.com/products/axis-q6075
2.5 Other technical data
Doc.-ID: 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx, Page 6 of 28
3 Safety Instructions
Please absolutely adhere to the directions for safety in the
installation instructions for the T08 ExCam series!
It is absolutely mandatory to observe the national safety regulations and regulations
for prevention of accidents, as well as the safety instructions given below in this
User Manual!
Attention!
Cameras of the type T08 ExCam are not suitable for use in zone 0 and
zone 20. The ambient temperature, temperature class and explosion
group as stated on type plate must be observed! Alterations are not
permitted! The camera is to be operated in sound conditions and in the
intended way.
Attention!
Only original parts of SAMCON Prozessleittechnik GmbH may be used
for repairs. Repairs concerning the explosion protection may only be
carried out in accordance with the nationally applied regulations and by
SAMCON Prozessleittechnik GmbH.
Attention!
Prior to installation, take external sources of heat or cold into account!
The temperature ranges prescribed for storage, transport and operation
must be adhered to!
Attention!
Observe the warnings given on the type plate:
“WARNING – DO NOT OPEN IN HAZARD AREAS“
“WARNING – DO NOT OPEN WHILE ENERGIZED“
The use in hazardous areas with regard to temperature and dust layers
is defined in the respective national regulations.
When installing the ExCam, adhere to the requirements of the EN/IEC
60079-14.
Doc.-ID: 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx, Page 7 of 28
4 Assembly
Work preparation:
Attention!
Prepare your work carefully and in accordance with the relevant
regulations.
Attention!
Depending on classification of hazard areas, a work approval has to be
obtained. When you open the pressure-resistant enclosure under voltage, it is absolutely necessary to prevent potentially explosive atmosphere!
To ensure the best image quality delivered by the network camera, plan the installation site
carefully (consider light conditions, object distance or size, angle and minimum object
distance to the focus).
Use appropriate tools and aids
When working, ensure a safe stand.
Make sure that any static charge is avoided
Attention!
Please pay attention to the national security, installation and accident
prevention regulations (e.g. DIN EN 60079-14) and the safety instructions given below in this User Manual, as well as the ones in the Installation Guidelines!
Attention!
Adhere to the provisions of the IECEx ATEX and
EX installation instructions for mounting and starting up!
ExCam® XPT Q6075 consists of a flame-proof camera housing (Ex-d) and a connection
chamber of a high degree of safety (Ex-e). Both areas are separated by a reinforced 5 m
line.
Mount the camera as high as possible, according to the desired field of view.
Install the connection chamber so that a good accessibility is provided, in order to facilitate
electrical connection.
Attention!
Please pay attention to the national and local regulations for mounting
heavy loads. In case of doubt, take appropriate security measures.
Doc.-ID: 200514-PT08BA-SS-ExCam XPT-Q6075_en_rev.00.docx, Page 8 of 28
Wall bracket
WMB-...
WALL MOUNT EXCAM XPT (01538-001)
Wall bracket for the T08-TNXCD series
Suitable for hanging the camera on walls.
The scope of delivery includes a protective cover
for the wall bracket. The cover protects the cable
and cable routing as required by 60079-14 and
does not let the cable and cable glands be directly
exposed to water splashes.
Material: stainless steel 1.4404
Load bearing: 45 kg
Dimensions: 460 x 140 x 220 mm
Pole adapter
PMB-…
POLE MOUNT EXCAM XPT (01539-001)
TNXCD pole adapter for wall mount
Material: stainless steel 1.4404
Suitable for pole diameters
between 110 and 150 mm
Load-bearing capacity: 50 kg
Ceiling adapter
CMB-…
CEILING MOUNT EXCAM XPT
TNXCD pole adapter for ceiling mount
Material: stainless steel 1.4404
Load-bearing capacity: 50 kg
Drawings for drill hole patterns and further information can be viewed on our product
page: