1 Introduction .............................................................................................................. 4
2 Technical Data .......................................................................................................... 4
2.1 Parameters of the explosion protection ............................................................... 4
2.2 Electrical parameters of the camera .................................................................... 5
2.3 System cable SKD04-T.flex ................................................................................ 5
2.4 Technical specification of the camera module ..................................................... 6
2.5 Other technical data ............................................................................................ 6
3 Safety Instructions ................................................................................................... 7
4 Commissioning ........................................................................................................ 8
5 Electrical connection ............................................................................................. 10
5.1 Potential equalization ........................................................................................ 10
5.2 Connection and Fusing ..................................................................................... 11
5.2.1 Network interface / plug assignment (RJ45) ............................................................................ 12
5.2.2 Connection to a terminal box (alternatively) ............................................................................ 12
5.3 Example: external connection and fusing via the terminal box .......................... 15
5.3.1 Example: direct routing from the ExTB-3 to the safe area ...................................................... 15
5.3.2 Example: Routing via ExConnection Rail (optional accessories) ............................................ 16
5.3.3 Appropriate cables & cable entries .......................................................................................... 17
5.3.4 Cable kits - "plug and play" connection packages ................................................................... 18
5.3.5 Tests prior to switching on the voltage .................................................................................... 19
6 Hardware Reset ...................................................................................................... 20
6.1 Work preparation ............................................................................................... 20
6.2 Opening the pressure-resistant housing ............................................................ 20
6.3 Closing of the pressure-resistant housing ......................................................... 23
7 Network access and visualization ........................................................................ 23
7.1 Browser Support................................................................................................ 23
7.2 Assigning the IP address ................................................................................... 24
7.3 Password / identification .................................................................................... 24
8 Maintenance / Servicing / Alterations ................................................................... 25
9 Repairs and Maintenance ...................................................................................... 25
10 Disposal / Recycling ........................................................................................... 25
11 Drawings & 3D models ....................................................................................... 25
12 Certificates and further documentation ............................................................ 27
Rev.- Index
Date
Name
Remarks
Authorization of the EX Supervisor
0
Sep. 24, 2019
E. Schneider
Compilation of the document
1
Nov. 19, 2019
E. Schneider
Adjustment of certain values (temperature, wall mount)
Digital unterschrieben von Steffen Seibert DN: cn=Steffen Seibert, o=SAMCON, ou, email=s.seibert@samcon.eu, c=DE Datum: 2019.11.25 11:24:07 +01'00'
Table of Figures
Fig. 2-1 Sectional view of SKD04-T.flex ............................................................................ 5
Tab. 4-1 Mounting Accessories ......................................................................................... 9
Fig. 5-1 ExCam XF M3016 Equipotential Bonding .......................................................... 10
Tab. 5-1 Equipotential Bonding ....................................................................................... 11
Fig. 5-2 Cable gland (KLE) and supply line ..................................................................... 11
Fig. 5-3 ExCam XF M3016 T08-VA1.2.K1.BOR-N.N-005.N-P-090 ................................. 11
Tab. 5-2 Electrical connection ......................................................................................... 13
Fig. 5-4 Video Tutorial ExTB-3 ........................................................................................ 14
Fig 5-5 Connection to a terminal box ............................................................................... 14
Fig 5-6 ExTB-3 -> Safe area ............................................................................................ 15
Fig. 5-7 ExTB-3 -> ExConnection Rail ............................................................................. 16
Fig. 5-8 Barrier gland ....................................................................................................... 17
Fig. 5-9 Cable kit – plug & play connection package ....................................................... 18
Tab. 5-3 Available cable kits ............................................................................................ 19
Fig. 6-1 Opening the ExCam XF M3016 .......................................................................... 21
Fig. 6-2 Location of the control button ............................................................................. 21
Fig. 6-3 Disconnecting the mounting adapter .................................................................. 22
Fig. 8-1 Axis IP Utility ...................................................................................................... 24
Fig. 11-1 – Dimensions of the T08 ExCam XF M3016 .................................................... 27
Revision history
Product: ExCam® XF M3016 Title: User manual ExCam® XF M3016 Doc. -Id. 190917-PT08BA-ES-ExCam XF M3016_en_rev.01.docx Author: Eva Schneider Date: September 24, 2019 Latest update: November 19, 2019
1 Introduction
The ExCam XF M3016 is an ultra-compact and powerful IP-Megapixel-camera which can be used within hazardous areas. Despite its ultra-compact design, it offers Full HDTV resolution (1080p) in combination with a wide-angle lens.
The ExCam series is certified both in accordance with the European (ATEX) and interna­tional (IECEx) directive. The explosion-protected housing is approved for ATEX group II for zones 1, 2, 21 and 22 including the explosion groups IIC / IIIC. The T08 ExCam certi­fication allows not only stationary device installation but also mobile applications (hand­held use, etc.). To see other approvals, please visit our website at www.samcon.eu.
When designing the ExCam XF M3016, we focused very much on safety, mechanical precision and a high quality stainless steel.
2 Technical Data
2.1 Parameters of the explosion protection
Model key: T08-VA1.2.K1.BOR-N.N-005.N-P-090 Identification marks according to Directive RL 2014/34/EU: II 2G (Zone 1 and 2)
II 2D (Zone 21 and 22)
Explosion protection (gas): Ex db IIC T6 Gb Explosion protection (dust): Ex tb IIIC T80°C Db
Protection level: IP 68 (IEC/ EN 60529) Transportation / storage temperature: -5°C +50°C
Ambient temperature (EX): -5°C +50°C* (Type …N.N…) *intermitted (24/7 T
Noticed body: TÜV Rheinland (number 0035) EU Type Examination: TÜV 18 ATEX 8218 X (2018) IECEx certificate: IECEx TUR 18.0023X (2018) EAC-Ex TUR Report: TC RU C-DE.AБ.61.B.00381/19 Other certificates: siehe https://www.samcon.eu/en/products/network/excam-xf-m3016/
< 40°C)
amb
2.2 Electrical parameters of the camera
Power supply of the camera over Ethernet (PoE):
Voltage supply: PoE, IEEE 802.3af/802.3at type 1 class 1 Reference voltage: +48 V DC (44...54 V DC) Maximum power consumption: 3.8 W Typical power consumption: 2.9 W
2.3 System cable SKD04-T.flex
Description: Data transfer and power supply of the camera
module Jacket colour: Green (GN), similar to RAL 6018 Outside diameter: 8.7 ± 0.3 mm Bending radius: 8 x D
when installed and 4 x Da after installation
a
Temperature: -25°C … +80°C during installation
-60°C … +80°C fixed installed Data line: 4 x 2 x AWG24/7 blank, CAT.6 Shielding: Copper, tinned wire 0.10, optical cov. app. 80% Outer jacket/ Properties: PUR FHF, halogen-free, flame-retardant (EN
60332-1-2), EMV shielded, suitable for drag
chains,
(see www.samcon.eu)
Quicklink:
https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/SKD04-T.flex_Datasheett.pdf
Fig. 2-1 Sectional view of SKD04-T.flex
Kamera (Ex-d)
Permissible ambient temperature
-5°C … +50°C (intermitted; 24/7 T
amb
< 40°C)
Protection class as per EN 60529/IEC 529
IP68 (test conditions: 24h/3m water column 5°C) Housing material
Stainless steel, mat. no.: 1.4404
Weight
About. 3.0 kg
Dimensions
D79mm x 158mm
Attention! For wiring and connection of the camera, DIN/EN/IEC 60079-14 has to be observed. Especially for cross zone installation, measures against zone entrainment have to be taken.
2.4 Technical specification of the camera module
We use the AXIS M3016 network camera in a pressure-resistant enclosure. For details, please refer to the Product Documentation, video-technical data of AXIS®:
https://www.axis.com/products/axis-m3016/
2.5 Other technical data
3 Safety Instructions
Please absolutely observe the safety directions stated in the Ex-installation instructions of the T08 ExCam series!
Quick link:
https://www.samcon.eu/fileadmin/documents/en/22-Ex-Network-Cameras/ExCam-Series-T08-EX-Installation-Manual-2018.pdf
It is absolutely mandatory to observe the national safety regulations and regula­tions for prevention of accidents, as well as the safety instructions given below in this User Manual!
Attention! Cameras of the type T08 ExCam are not suitable for use in zone 0 and zone 20. The ambient temperature, temperature class and explosion group as stated on type plate must be observed! Alterations are not permitted! The camera is to be operated in sound conditions and in the intended way.
Attention! Only original parts of SAMCON Prozessleittechnik GmbH may be used for repairs. Repairs concerning the explosion protection may only be carried out in accordance with the nationally applied regulations and by SAMCON Prozessleittechnik GmbH.
Attention! Prior to installation, take external sources of heat or cold into account! The temperature ranges prescribed for storage, transportation, and operating must be adhered to!
Attention! Observe the warnings given on the type plate:
“WARNING – DO NOT OPEN IN HAZARD AREAS“
“WARNING – DO NOT OPEN WHILE ENERGIZED“
The use in hazardous areas with regard to temperature and dust lay­ers is defined in the respective national regulations.
When installing the ExCam, adhere to the requirements of the EN/IEC 60079-14.
4 Commissioning
For the camera’s installation and operation, the relevant national regulations, as well as
the generally accepted rules of technology shall prevail. Before mounting the camera, thoroughly check it for any transportation damages, especially at the housing and cable. Installation, electrical connection, and the first commissioning must only be carried out by qualified personnel.
Work preparation:
Attention! Prepare your work carefully and in accordance with the relevant regulations.
Attention! Depending on classification of hazard areas, a work approval has to be obtained! When you open the pressure-resistant enclosure under voltage, it is absolutely necessary to prevent potentially explosive atmosphere!
To ensure the best image quality delivered by the network camera, plan the installation site carefully (consider light conditions, object distance or size, angle and minimum object distance to the focus).
Use appropriate tools and aids. When working, ensure a safe stand. Make sure that any static charge is avoided
Attention! Please observe the national regulations regarding security, installa­tion, and accident prevention (e.g. DIN EN 60079-14) and the safety guidelines described in the user and in the EX installation manual!
Attention! Adhere to the provisions of the IECEx, ATEX and EX installation in­structions for mounting and commissioning!
The ExCam® XF M3016 is manufactured with a 5 m cable pigtail. The ending of the cam­era’s cable connection is furnished with a plug. Install the ExCam® XF M3016 at the de- sired location. Mounting options and conditions, accessories, as well as safety guidelines are described in the EX installation manual of the T08 ExCam® Series.
Wall mount bracket WMB-...
WALL MOUNT EXCAM XF M30 (02028-001)
Wall bracket for devices of T08-VA1.2-series Suitable for hanging the camera on walls. Material: stainless steel 1.4404 Weight: 0.68 kg Dimensions: 80 x 100 x 205 mm
Pole mount adapter PMB-
POLE MOUNT EXCAM VA1.x (-)
Pole apter for VA wall mount Material: stainless steel 1.4404 Suitable for pole diameters between 50 and 105 mm Load-bearing capacity: 45 kg Dimensions:120 x 180 (x 130 at masts of Ø 60 mm)
Weather Protec­tion Roof WPR­
WEATHERSHIELD EXCAM XF M30 (02033-001)
Weather shield for devices of the T08-VA1.2­series
Attention! Prior to the camera installation, take external sources of heat or cold into account! Observe the permissible temperature range!
Attention! Please pay attention to the national and local regulations for mounting heavy loads. If in doubt, take appropriate security measures.
Drawings for drill hole patterns and further information can be viewed on our product page:
Quick link:
https://www.samcon.eu/en/products/network/excam-xf-m3016/
Option mounting accessories
Tab. 4-1 Mounting Accessories
Loading...
+ 19 hidden pages