Axis D101-A XF P3807 Explosion-Protected Network Camera Installation Guide

SPECTRUM D101-(X)-P3807-BD Series

Explosion Proof Network Camera Installation Manual
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
1
This pageintentionallyleftblank
SERIES INSTALLATION MANUAL REV-1
2D101-A-P3807-PVE-BD REV 0 105607312018 D
07/23/2020
mentioned in this manual that are known to be trademarks have been appropriately capitalized. Spectrum Camera Solutions LLC acknowledges all trademark(s) and the rights of the trademark(s) owned by the company referred to herein.
Release Date:02/05/2020
Document Name D101-A-P3807-PVE-BD
© Copyright 2019 by Spectrum Camera Solutions LLC All rights
reserved

Revision Record

Rev. Description Date
0 Initial Release
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
3
Copyright Notice:
This document contains information proprietary to Spectrum Camera Solutions LLC with all rights reserved worldwide. Any reproduction or disclosure of this publication, or any part thereof, to persons other than Spectrum Camera Solutions, Inc. personnel or customers is strictly prohibited, except by written permission of Spectrum Camera Solutions, Inc. Unauthorized use, disclosure, reproduction, or translation of this publication will result in Spectrum Camera Solutions, Inc. exercising maximum possible legal action against all persons and / or organizations involved.
Disclaimer:
Spectrum Camera Solutions LLC makes no representations or warranties with respect to the contents hereof. Further, Spectrum Camera Solutions LLC reserves the right to revise this publication and to make changes in the content hereof, without obligation to notify any person or organization of such revision or changes.
Patent Notice:
Manufactured under United States US Patent 9917428 & US Patent D858611
Trademark Information:
Spectrum Camera Solutions LLC and its logo(s) are trademark(s) of Spectrum Camera Solutions LLC.
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
4

Table of Contents

Legal Notices and Revision History Inside front cover
DESCRIPTION 6
MODEL MATRIX 7
LABELS 8
STANDARDS AND CERTIFICATIONS 9
DOCUMENT SYMBOLS 10
HOW TO USE THIS MANUAL 11
Page
GENERAL SAFETY AND OPERATING INFORMATION 12
SPECIFICATIONS 15
UNBOXING 17
HARDWARE BOM 18
WIRING ENTRIES 19
INSTALLATION 20
DIMENTIONAL GENERAL ASSEMBLY 25
DISMANTLING & MAINTENANCE 26
MOUNTING OPTIONS 28
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
5
DESCRIPTION
The “D” Series includes a full range of Stainless Steel or Anodized Aluminum camera stations specifically designed for Hazardous Area Applications.
Spectrum’s D Series is the first Class I II III Division 1 rated dome style explosion proof housings and utilizes the most robust and advanced camera technologies available. The D Series was designed with the integrator in mind and offers features not available in competing EX camera systems available in the market. The solution is Patented with features including a uniform constructed enclosure consisting of an integrated junction box milled directly to the camera housing. This eliminates the need for extra equipment, reduces installation time, reduces labor expenses, and increases safety by lessening the potential for mismatched hazardous rated components. Additionally, the D Series are constructed with a proprietary explosion resistant polymer blend offering maximum clarity and enhance optical performance. To enhance optical performance, the explosion proof lens is equipped with our Virtual Wiper Nano Technology. The series are available in anodized aluminum or 316L Stainless steel ensuring protection against rain, dust and corrosion within a wide temperature range between ­20°C to 55°C. This feature ensures operation under extreme weather conditions and hazardous environments. It is suitable for monitoring wide open indoor/outdoor spaces such as refineries, wellheads, pipelines, offshore installations, remote and harsh locations where high-level reliability and precision are always required.
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
6

Option A- Model Matrix- D100-D500*

CODE “XX”
01
D(N)(XX)-(1)-(CCCCCC)-BD
N=(1) HOUSING LENGTH=3.32 in N=(2) HOUSING LENGTH=7.75 in N=(3) HOUSING LENGTH=4.5 in N=(4) HOUSING LENGTH=5 in N=(5) HOUSING LENGTH= 5.5 in XX= Internal Equipment Manufacturer Code** 1= (A) Aluminum Housing with SS 316L Dome Ring 1= (S) Stainless Steel 316L Housing C= Internal Equipment Part Number from Manufacturer*** BD= Optional Breather drain model**** *Internal components and D Series must be approved by Spectrum **Internal Equipment Manufacturer Code below ***Must be approved and verified by Spectrum ****Models supplied with Breather Drains will have IP66 ingress protection level
Manufacture AXIS COMMUNICATIONS
D101-A-P3807-PVE-BD REV 0 105607312018 D
SERIES INSTALLATION MANUAL REV-1
7

Labels Option A

BREATHER DRAIN MODEL
BREATHER DRAIN MODEL
SERIES INSTALLATION MANUAL REV-1
8D101-A-P3807-PVE-BD REV 0 105607312018 D

STANDARDS & CERTIFICATIONS

STANDARDS-
The equipment is manufactured in accordance with the IECEX scheme, the ATEX Directive 94/9CE and with the following standards : IEC 60079-0:2011 IEC 60079-1:2014 IEC 60079-31:2013 IEC 60529:2013 EN 60079-0:2012 + A11:2013 EN 60079-1:2014 EN 60079-31:2014 EN 60529:1991 + A1:2000 + A2:2013 ANSI/ISA 60079-0:2013 ANSI/UL 60079-1:2015 ANSI/ISA 60079-31:2015 ANSI/IEC 60529:2004 CAN/CSA-C22.2 No. 60079-0:2015 CAN/CSA-C22.2 No. 60079-1:2016 CAN/CSA-C22.2 No. 60079-31:2015 CAN/CSA-C22.2 No. 60529:2016
Specific Conditions of Use:
-The flameproof joints of the equipment are not intended to be repaired. Consult the manufacturer if dimensional information on the flameproof joints is necessary.
-Follow the manufacturer’s instructions to reduce the potential of an electrostatic charging hazard on the surface of the equipment in Group II and III environments.
-The equipment meets the requirements according to the low-level risk of mechanical danger. Therefore, the equipment shall be located and installed such that the risk of impact or other mechanical damage is reduced or avoided.
CERTIFICATIONS-
CERT NO. FM17US0156X & FM18CA0103X Class I Division 1 Groups B,C,D T6, Ta = -20°C to +55°CType 4X, IP66 Class II/III, Division 1, Groups E,F,G T6 Type 4X, IP66 Ta = -20°C to +55°C Class I, Zone 1, AEx/Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, Type 4X, IP66 Zone 21, AEx/Ex tb IIIC T85°C Db Ta = -20°C to +55°C, Type 4X, IP66 CERT NO. FM18ATEX0057X & IECEx FMG 18.0020X II 2 G Ex db IIB+H2 T6 Gb Ta = -20°C to +55°C, IP66 II 2 D Ex tb IIIC T85°C Db Ta = -20°C to +55°C, IP66
SERIES INSTALLATION MANUAL REV-1
9D101-A-P3807-PVE-BD REV 0 105607312018 D

DOCUMENT SYMBOLS

The following symbols are used throughout this manual to alert users to potential hazards or important information. Failure to heed the warnings and cautions listed
herein can lead to injury and equipment damage.
Symbol Label Description
WARNING:
CAUTION:
Consists of conditions, practices, or procedures that must be observed to prevent personal injury and/or equipment damage.
Risk of electric shock or high temperature parts may result in injury if proper precautions are not taken.
NOTE:
Emphasizes important or essential information.
Locating Information:
NOTE: In the interest of completeness, manuals and drawings included with the
system may provide information pertaining to options not included with your equipment. Information in application notes supersedes general information in these documents. Information can be in this manual using any of the following aids.
SERIES INSTALLATION MANUAL REV-1
10D101-A-P3807-PVE-BD REV 0 105607312018 D