Axis A1001 Installation Guide

AXISA1001NetworkDoorController
InstallationGuide
English
EN
France:Français
Italia:Italiano
España:Español
FR
DE
IT
ES
Liability
Everycarehasbeentakeninthepreparationofthis document.PleaseinformyourlocalAxisofceofany inaccuraciesoromissions.AxisCommunicationsABcannot beheldresponsibleforanytechnicalortypographicalerrors andreservestherighttomakechangestotheproductand manualswithoutpriornotice.AxisCommunicationsAB makesnowarrantyofanykindwithregardtothematerial containedwithinthisdocument,including,butnotlimited to,theimpliedwarrantiesofmerchantabilityandtnessfor aparticularpurpose.AxisCommunicationsABshallnot beliablenorresponsibleforincidentalorconsequential damagesinconnectionwiththefurnishing,performance oruseofthismaterial.Thisproductisonlytobeusedfor itsintendedpurpose.
Intellectualpropertyrights
AxisABhasintellectualpropertyrightsrelatingto technologyembodiedintheproductdescribedinthis document.Inparticular,andwithoutlimitation,these intellectualpropertyrightsmayincludeoneormoreof thepatentslistedataxis.com/patentandoneormore additionalpatentsorpendingpatentapplicationsinthe USandothercountries.
ThisproductcontainssourcecodecopyrightApple Computer,Inc.,underthetermsofApplePublicSource License2.0(seeopensource.apple.com/apsl).Thesource codeisavailablefromdeveloper.apple.com/bonjour/
Equipmentmodications
Thisequipmentmustbeinstalledandusedin strictaccordancewiththeinstructionsgiveninthe userdocumentation.Thisequipmentcontainsno user-serviceablecomponents.Unauthorizedequipment changesormodicationswillinvalidateallapplicable regulatorycerticationsandapprovals.
Trademarkacknowledgements
AXISCOMMUNICATIONS,AXISandVAPIXareregistered trademarksortrademarkapplicationsofAxisABinvarious jurisdictions.Allothercompanynamesandproductsare trademarksorregisteredtrademarksoftheirrespective companies.
AssaandAperioaretrademarksorregisteredtrademarksof ASSAABLOYAB.
SimonsVossandSmartIntegoaretrademarksorregistered trademarksbelongingSimonsVossTechnologiesGmbH
HID,HIDGlobal,theHIDBlueBricklogo,HIDMobileAccess, iCLASSSE,Seos,Prox,andSecureIdentityServicesare trademarksorregisteredtrademarksofHIDGlobalinthe U.S.and/orothercountries.
NetworkTimeProtocolVersion4Distributioniscopyright ofUniversityofDelaware–©UniversityofDelaware 1992–201 1.Thefollowingcopyrightnoticeappliestoall lescollectivelycalledtheNetworkTimeProtocolVersion 4Distribution.Unlessspecicallydeclaredotherwisein anindividualle,thisnoticeappliesasifthetextwas explicitlyincludedinthele.Permissiontouse,copy, modify,anddistributethissoftwareanditsdocumentation foranypurposewithorwithoutfeeisherebygranted, providedthattheabovecopyrightnoticeappearsin allcopiesandthatboththecopyrightnoticeandthis permissionnoticeappearinsupportingdocumentation, andthatthenameUniversityofDelawarenotbeusedin advertisingorpertainingtodistributionofthesoftware withoutspecic,writtenpriorpermission.TheUniversity ofDelawaremakesnorepresentationsaboutthesuitability
thissoftwareforanypurpose.Itisprovided"asis"without expressorimpliedwarranty.
Support
Shouldyourequireanytechnicalassistance,pleasecontact yourAxisreseller.Ifyourquestionscannotbeanswered immediately,yourresellerwillforwardyourqueriesthrough theappropriatechannelstoensurearapidresponse.Ifyou areconnectedtotheInternet,youcan:
downloaduserdocumentationandsoftwareupdates
ndanswerstoresolvedproblemsintheFAQdatabase,
searchbyproduct,category,orphrase
reportproblemstoAxissupportstaffbylogginginto
yourprivatesupportarea
chatwithAxissupportstaff
visitAxisSupportataxis.com/support
Learnmore!
VisitAxislearningcenteraxis.com/academyforuseful trainings,webinars,tutorialsandguides.
Regulatoryinformation
Europe
ThisproductcomplieswiththeapplicableCEmarking directivesandharmonizedstandards:
ElectromagneticCompatibility(EMC)Directive
2014/30/EU.SeeElectromagneticcompatibility(EMC) onpage4.
LowVoltageDirective(LVD)2014/35/EU.SeeSafety
onpage5.
RestrictionofHazardousSubstances(RoHS)Directive
201 1/65/EU,includinganyamendments,updatesor
replacements.SeeDisposalandrecyclingonpage5. Acopyoftheoriginaldeclarationofconformitymaybe obtainedfromAxisCommunicationsAB.SeeContact informationonpage5.
Electromagneticcompatibility(EMC)
Thisequipmenthasbeendesignedandtestedtofulll applicablestandardsfor:
Radiofrequencyemissionwheninstalledaccordingto
theinstructionsandusedinitsintendedenvironment.
Immunitytoelectricalandelectromagneticphenomena
wheninstalledaccordingtotheinstructionsandused
initsintendedenvironment.
USA
Thisequipmenthasbeentestedusingashieldednetwork cable(STP)andfoundtocomplywiththelimitsfora ClassBdigitaldevice,pursuanttopart15oftheFCC Rules.Theselimitsaredesignedtoprovidereasonable protectionagainstharmfulinterferenceinaresidential installation.Thisequipmentgenerates,usesandcan radiateradiofrequencyenergyand,ifnotinstalledand usedinaccordancewiththeinstructions,maycause harmfulinterferencetoradiocommunications.However, thereisnoguaranteethatinterferencewillnotoccurin aparticularinstallation.Ifthisequipmentdoescause harmfulinterferencetoradioortelevisionreception,which canbedeterminedbyturningtheequipmentoffandon, theuserisencouragedtotrytocorrecttheinterferenceby oneormoreofthefollowingmeasures:
Reorientorrelocatethereceivingantenna.
Increasetheseparationbetweentheequipmentand
receiver.
Connecttheequipmentintoanoutletonacircuit
differentfromthattowhichthereceiverisconnected.
Consultthedealeroranexperiencedradio/TV
technicianforhelp. Theproductshallbeconnectedusingashieldednetwork cable(STP)thatisproperlygrounded.
Canada
ThisdigitalapparatuscomplieswithCANICES-3(ClassB). Theproductshallbeconnectedusingashieldednetwork cable(STP)thatisproperlygrounded.Cetappareil numériqueestconformeàlanormeCANNMB-3(classeB). Leproduitdoitêtreconnectéàl'aided'uncâbleréseau blindé(STP)quiestcorrectementmisàlaterre.
Europe
ThisdigitalequipmentfulllstherequirementsforRF emissionaccordingtotheClassBlimitofEN55022.The productshallbeconnectedusingashieldednetworkcable (STP)thatisproperlygrounded.
Australia/NewZealand
ThisdigitalequipmentfulllstherequirementsforRF emissionaccordingtotheClassBlimitofAS/NZSCISPR22. Theproductshallbeconnectedusingashieldednetwork cable(STP)thatisproperlygrounded.
Japan
この装置は、クラスB情報技術装置です。この装置 は、家庭環境で使⽤することを⽬的としています が、この装置がラジオやテレビジョン受信機に近 接して使⽤されると、受信障害を引き起こすこと があります。取扱説明書に従って正しい取り扱い をして下さい。本製品は、シールドネットワーク ケーブル(STP)を使⽤して接続してください。また 適切に接地してください。
Safety
ThisproductcomplieswithIEC/EN60950-1,Safetyof InformationTechnologyEquipment.
Ifitsconnectingcablesareroutedoutdoors,theproduct shallbegroundedeitherthroughashieldednetworkcable (STP)orotherappropriatemethod.
Thepowersupplyusedwiththisproductshallfullloneof thefollowingrequirements:
SafetyExtraLowVoltage(SELV)accordingtoclause
2.2ofIEC/EN/UL60950-1andLimitedPowerSource
(LPS)accordingtoclause2.5ofIEC/EN/UL60950-1or
CEC/NECClass2sourceofsupplyasdenedinthe
CanadianElectricalCode,CSAC22.1andNational
ElectricalCode,ANSI/NFPA70
Class1electricalenergysource(ES1)andClass2power
source(PS2)ratedoutputpowerlimitedto
≤100WaccordingtoIEC/EN/UL62368-1
Disposalandrecycling
Whenthisproducthasreachedtheendofitsusefullife, disposeofitaccordingtolocallawsandregulations.For informationaboutyournearestdesignatedcollectionpoint, contactyourlocalauthorityresponsibleforwastedisposal. Inaccordancewithlocallegislation,penaltiesmaybe applicableforincorrectdisposalofthiswaste.
Europe
Thissymbolmeansthattheproductshallnotbe disposedoftogetherwithhouseholdorcommercialwaste. Directive2012/19/EUonwasteelectricalandelectronic equipment(WEEE)isapplicableintheEuropeanUnion memberstates.Topreventpotentialharmtohumanhealth andtheenvironment,theproductmustbedisposedofin anapprovedandenvironmentallysaferecyclingprocess. Forinformationaboutyournearestdesignatedcollection
point,contactyourlocalauthorityresponsibleforwaste disposal.Businessesshouldcontacttheproductsupplierfor informationabouthowtodisposeofthisproductcorrectly.
Thisproductcomplieswiththerequirementsof Directive201 1/65/EUontherestrictionoftheuseof certainhazardoussubstancesinelectricalandelectronic equipment(RoHS).
China
Thisproductcomplieswiththerequirementsof SJ/T1 1364-2014,Markingfortherestrictionofhazardous substancesinelectricalandelectronicproducts.
有毒有害物质或元素
部 件 名 称
电 气 实 装 部 分
0:表示该有毒有害物质在该部件所有均质材料中 的含量均在GB/T26572标准规定的限量要求以下。
X:表示该有毒有害物质至少在该部件的某一均质 材料中的含量超出GB/T26572标准规定的限量要 求。
Contactinformation
AxisCommunicationsAB Emdalavägen14 22369Lund Sweden
Tel:+46462721800 Fax:+4646136130
axis.com
SupportedReaders
Thislistofsupportedreadersissubjecttochangewithout notice.ContactyourAxisresellerforinformationabout supportedreaders.
ThisproductiscompatiblewithULListedWiegandaccess controlreaders
ThisproductiscompatiblewiththefollowingRS485access controlreaders:
AXISA4011-EReader
HIDiCLASS®RW100:6101CG40000,6101CGM0000, 6101CK40000,6101CK40002,6101CK40100, 6101CK403C0,6101CKM0000,6101CKM0002, 6101CKM0203;RW300:611 1CG40000,611 1CG400C0, 61 11CGM0000,6111CK40000,6111CK4000Z, 61 11CKM0000;RW400:6121CG40000,6121CGM0000, 6121CK40000,6121CK40003,6121CK40007-G3.0, 6121CK4000D-G3.0,6121CKM0000;R40: 6122CKP00P0,6122CKP05P0,6122CKP06P0;RWK400: 6131CG4020000,6131CK4000000,6131CK4000014,
(Pb)
X
(Hg)
(Cd)
00000
六价
多溴
(Cr­(VI))
多溴
联苯
二苯
(PB-
B)
(PB­DE)
6131CK4000300,6131CK4020000,6131CKM000000, 6131CKM000214;RK40:6132BKP00Q709-G3.0, 6132CKP000009,6132CKP000011,6132CKP000700-G3.0, 6132CKP000709-G3.0,6132CKP001009,6132CKP00101 1, 6132CKP00P000,6132CKP00P009,6132CKP00P709-G3.0, 6132CKP00Q709-G3.0,6132CKP030014,6132CKP060514, 6132CKP06P009,6132CKP06P609,6132CKP070209; RW150:6141CG40000,6141CGM0000,6141CK40000, 6141CKM0000;R15:6142CKP000Z,6142CKP00P0, 6142CKP0100;RWKL550:6171BK4000000, 6171BK4000009,6171BK4000014,6171BK4000214, 6171BK4000500,6171BK4040Z14,6171BK4060000, 6171BK4060209,6171BK4060Z09,6171BK4061000, 6171BKM000000,6171BKM000200,6171BKM000300, 6171BKM040400;RWKLB575:6181BK4000000, 6181BK4000009,6181BK4000014,6181BK4000022, 6181BK406C009;
HIDSmartid®:8031DSAP HIDpivClass®R10-H:900LHRNAK00000,
900LHRTAK00000,900NHRNAK00000,900NHRTAK00000, 900PHRNAK00000,900PHRTAK00000,910LHRNAK00000, 910LHRTAK00000,910NHRNAK00000,910NHRTAK00000, 910PHRNAK00000,910PHRTAK00000,920LHRNAK00000, 920LHRTAK00000,920NHRNAK00000,920NHRTAK00000, 920PHRNAK00000,920PHRTAK00000,921LHRNAK00000, 921LHRTAK00000,921NHRNAK00000,921NHRTAK00000, 921PHRNAK00000,921PHRTAK00000;RPKCL40-P: 923LPRNAK00000,923LPRTAK00000,923NPRTAK00000, 923PPRNAK00000,923PPRTAK00000
TM
Aptiq
:M1 1,MTK15,MTMSK15,MT15,MTMS15
ForinformationaboutwhichcompatibleRS485access controlreadershavebeenveriedbyUL,seeRequirements forCompliancewithUL2946thEditiononpage7.
AXISA1001NetworkDoorController
RequirementsforCompliancewithUL2946thEdition
ThissectioncontainsinformationandinstructionsrequiredforULcompliance.Tomakesurethe installationisULcompliant,followtheinstructionsbelowinadditiontothegeneralinformation andinstructionsprovidedthroughoutthisdocument.Incaseswherepiecesofinformation contradicteachother,therequirementsforULcompliancealwaysreplacegeneralinformation andinstructions.
Supportedreaders
•CompatibilitywiththefollowingRS485readershasbeenveriedbyUL:HIDiClassRK40, HIDSmartID8031DSHM,andAptiqQMTMSK15.
Safetyinstructions
•TheAxisproductshallbeinstalledandservicedbyafactorytrainedprofessional.
•TheAxisproductshallbeinstalledwithintheprotectedpremises(securedarea).
•TheAxisproductshallbemountedindoors.Outdoorusehasnotbeenevaluatedor approvedbyUL.
•AllinterconnectingdevicesshallbeULListedandClass2low-voltagepowerlimited.
•AllwiringmethodsshallbeperformedinaccordancewithNFPA70,localcodesand authoritieshavingjurisdiction.
•WhentheAxisproducthasreachedtheendofitsusefullife,disposeofitaccording tolocallawsandregulations.Theproductshouldnotbedisposedoftogetherwith householdorcommercialwaste.SeeDisposalandrecycling.
Battery
-The3.0VlithiumbatteryusedbytheAxisproductisaULRecognized component.(Type:BR2032,diameter:20mm(0.78in),manufacturers: Rayovac,Panasonic).ThefollowingbatterytypeisalsoaULRecognized component:TypeCR2032,manufacturers:Fuji,Maxell,Renata,Varta, Panasonic,JHIH
-Usersshallnotreplacethebattery.Ifthebatteryneedsreplacing, afactorytrainedserviceprofessionalshallcontactAxissupport atwww.axis.com/techsupforassistance.
-Usedbatteriesshallbedisposedofaccordingtolocallawsandregulations, whichmayvaryfromstatetostate.WasteBR/CRlithiumcellsareneither listednorexemptedfromtheUSEPAhazardouswasteregulations.Waste lithiumbatteriescanbeconsideredreactivehazardouswasteifthereisa signicantamountofunreacted,orunconsumedlithiumremaining.For informationabouthowtodisposeofusedlithiumbatteries,contactyourlocal authorityforwastedisposal.
Specications
Operatingconditions
-Temperatures0°Cto50°C(32°Fto122°F).
7
AXISA1001NetworkDoorController
Wirearea
-ULListedorR/CAWMwiresthathaveanconductorgaugerangeof AWG22–14shallbeused.
-Theminimumconductorgaugeforconnectionbetweenthepowersourcing equipment(PSE)orpowerinjectorandthepowereddevice(PD)is26AWG.
Connectors
-ThisproductisnotintendedforoutsidewiringascoveredbyArticle800inthe NationalElectricalCode,NFPA70.
-Powerconnector–ForULsecurityapplications,theproductshallbepowered byaUL294ListedorUL603ListedClass2low-voltagepowerlimitedpower supplythatiscapableof4hoursofstandbypower.
-Networkconnector–PoweroverEthernet(PoE)shallbesuppliedbyaUL294 ListedClass2powerlimitedinjectorthatprovides44–57VDC,15.4Wand4 hoursofstandbypower.CompliancewithIEEE802.3(atoraf)specications hasnotbeenveriedaspartofUL294/B.
-Tamperingalarmpinheader–TocomplywithUL294/7.2.1(Enclosure),the tamperingalarmshallbeconnectedtoasoundalarm.
Systemconsiderations
-TheAxisproduct,whetheritisastandalonedoorcontrollerorasystemof doorcontrollers,shallnotimpairtheintendedoperationofthepanichardware usedinconjunctionwithit.
Wallandceilingmount
-IfusingajunctionboxtomounttheAxisproduct,thejunctionboxshallbe ULListed.
AssignanIPaddress
-ThefunctionalityofAXISDeviceManager,seetheUserManual,hasnotbeen evaluatedbyUL.
Maintenanceinstructions
-Formaintenanceinstructions(somestepsrequireaccesstotheproduct’s webpages),seetheUserManual.Forinformationabouthowtocongure theAxisproductusingtheproduct’swebpages(AXISEntryManager),see theUserManual.
Furtherinformation
-Firmwareversion:DoorController,ModelA1001–1.20.2
8
AXISA1001NetworkDoorController
Safetyinformation
Hazardlevels
DANGER
Indicatesahazardoussituationwhich,ifnotavoided,willresultindeathorseriousinjury.
WARNING
Indicatesahazardoussituationwhich,ifnotavoided,couldresultindeathorseriousinjury.
CAUTION
Indicatesahazardoussituationwhich,ifnotavoided,couldresultinminorormoderate injury.
NO
TICE
NO NO
TICE TICE
Indicatesasituationwhich,ifnotavoided,couldresultindamagetoproperty.
Othermessagelevels
Important
Indicatessignicantinformationwhichisessentialfortheproducttofunctioncorrectly.
Note
Indicatesusefulinformationwhichhelpsingettingthemostoutoftheproduct.
EN
9
AXISA1001NetworkDoorController
Safetyinstructions
WARNING
TheAxisproductshallbeinstalledbyatrainedprofessional,andincompliancewithlocal lawsandregulations.
NO
TICE
NO NO
TICE TICE
•TheAxisproductshallbeusedincompliancewithlocallawsandregulations.
•Axisrecommendsusingashieldednetworkcable(STP)CAT5orhigher.
•TousetheAxisproductoutdoors,orinsimilarenvironments,itshallbeinstalledinan approvedoutdoorhousing.
•StoretheAxisproductinadryandventilatedenvironment.
•AvoidexposingtheAxisproducttoshocksorheavypressure.
•Donotinstalltheproductonunstablepoles,brackets,surfacesorwalls.
•UseonlyapplicabletoolswheninstallingtheAxisproduct.Usingexcessiveforcewith powertoolscouldcausedamagetotheproduct.
•Donotusechemicals,causticagents,oraerosolcleaners.
•Useacleanclothdampenedwithpurewaterforcleaning.
•Useonlyaccessoriesthatcomplywiththetechnicalspecicationofyourproduct.These canbeprovidedbyAxisorathirdparty.AxisrecommendsusingAxispowersource equipmentcompatiblewithyourproduct.
•UseonlysparepartsprovidedbyorrecommendedbyAxis.
•Donotattempttorepairtheproductyourself.ContactAxissupportoryourAxisreseller forservicematters.
•Thepowersupplyshallbepluggedintoasocketoutletinstalledneartheproductand shallbeeasilyaccessible.
•Usealimitedpowersource(LPS)witheitheraratedoutputpowerlimitedto≤100Wora ratedoutputcurrentlimitedto≤5A.
Transportation
NO
TICE
NO NO
TICE TICE
•WhentransportingtheAxisproduct,usetheoriginalpackagingorequivalenttoprevent damagetotheproduct.
Battery
TheAxisproductusesa3.0VCR2032lithiumbatteryasthepowersupplyforitsinternalreal-time clock(RTC).Undernormalconditionsthisbatterywilllastforaminimumofveyears.
10
AXISA1001NetworkDoorController
LowbatterypoweraffectstheoperationoftheRTC,causingittoresetateverypower-up.When thebatteryneedsreplacing,alogmessagewillappearintheproduct’sserverreport.Formore informationabouttheserverreport,seetheproduct´swebpageorcontactAxissupport.
Lithiumcoincell3.0Vbatteriescontain1,2-dimethoxyethane;ethyleneglycoldimethylether (EGDME),CASno.110-71-4.
WARNING
•Riskofexplosionifthebatteryisincorrectlyreplaced.
•Thebatteryshouldbereplacedwithanidenticalbatteryonly.
•Usedbatteriesshouldbedisposedofaccordingtolocalregulationsorthebattery manufacturer'sinstructions.
EN
11
12
AXISA1001NetworkDoorController
InstallationGuide-FullReference
ThisfullreferenceinstallationguideprovidesinstructionsforhowtoinstallAXISA1001Network DoorControlleronyournetwork.
•Foraquickreferenceguide,seetheprintedAXISA1001InstallationGuide–Quick
Referencethatisincludedinthepackagecontents.Thequickreferenceguideisalso availableonwww.axis.com
•Forotheraspectsofusingtheproduct,seetheAXISA1001UserManualavailable
onwww.axis.com
InstallationSteps
1.Makesurethepackagecontents,toolsandothermaterialsnecessaryfortheinstallation
areinorder.Seepage13.
2.Studythehardwareoverview.Seepage15.
3.Studythespecications.Seepage20.
4.Installthehardware.Seepage30.
5.Accesstheproduct.SeeAccesstheProductonpage37.
Packagecontents
•AXISA1001NetworkDoorController
•Cabletie(4x)
•Coverscrew
•6-pinplugconnector(5x)(pluggedintoterminalconnectors)
-ReaderI/O(blue)
-ReaderI/O(red)
-Readerdata(white)
-Readerdata(yellow)
-Power&Relay(orange)
•4-pinplugconnector(5x)(pluggedintoterminalconnectors)
-Audio(white)
-Auxiliary(yellow)
-Doorin(blue)
-Doorin(red)
-Powerlock(orange)
•2-pinplugconnector(pluggedintoterminalconnector)
-Power(black)
EN
13
AXISA1001NetworkDoorController
•Printedmaterials
-AXISA1001InstallationGuide–QuickReference
-Extraserialnumberlabel(2x)
-AVHSAuthenticationkey
RecommendedTools
•Drill–ifmountingonwallorceiling
•Screwdriver–ifmountingonwallorceiling
•Slottedscrewdriver–foropeningthecover
•Torxscrewdriver(T10)–fortighteningthecoverscrew
•Wirestrippingtool
14
Hardwareoverview
AXISA1001NetworkDoorController
EN
Frontandback:
1
Cover
2
Coverscrew
3
Coverremovalslot
4
Base
5
DINclip–upper
6
Tamperingalarmswitch–back
7
DINclip–lower
8
Partnumber(P/N)&Serialnumber(S/N)
15
AXISA1001NetworkDoorController
I/Ointerface:
1
Readerdataconnector(READERDATA1)
10
Readerdataconnector(READERDATA2)
3
ReaderI/Oconnector(READERI/O1)
8
ReaderI/Oconnector(READERI/O2)
4
Doorconnector(DOORIN1)
7
Doorconnector(DOORIN2)
6
Auxiliaryconnector(AUX)
5
Audioconnector(AUDIO)(notused)
Externalpowerinputs:
2
Powerconnector(DCIN)
12
Networkconnector(PoE)
Poweroutputs:
9
Powerlockconnector(LOCK)
11
Power&Relayconnector(PWR,RELAY)
16
AXISA1001NetworkDoorController
LEDindicators,buttonsandotherhardware:
1
PowerLEDindicator
2
StatusLEDindicator
3
NetworkLEDindicator
4
Reader2LEDindicator(notused)
5
Reader1LEDindicator(notused)
6
Tamperingalarmpinheader–front(TF)
7
Tamperingalarmpinheader–back(TB)
8
LockLEDindicator
9
LockLEDindicator
10
Tamperingalarmsensor–front
11
SDcardslot(microSDHC)(notused)
12
Controlbutton
13
Partnumber(P/N)&Serialnumber(S/N)
EN
17
AXISA1001NetworkDoorController
LEDIndicators
LED
Network
Status
Power
Lock
Note
•TheStatusLEDcanbeconguredtoashwhileaneventisactive.
•TheStatusLEDcanbeconguredtoashforidentifyingtheunit.GotoSetup>
Color
Green
Amber
UnlitNonetworkconnection. GreenSteadygreenfornormaloperation. Amber Red
Green Amber
GreenSteadywhennotenergized. Red UnlitFloating.
AdditionalControllerConguration>SystemOptions>Maintenance.
Indication
Steadyforconnectiontoa100MBit/snetwork.Flashesfor networkactivity.
Steadyforconnectiontoa10MBit/snetwork.Flashesfornetwork activity.
Steadyduringstartupandwhenrestoringsettings. Slowashforfailedupgrade. Normaloperation.
Flashesgreen/amberduringrmwareupgrade.
Steadywhenenergized.
ConnectorsandButtons
Forspecicationsandoperatingconditions,seepage20.
I/OInterface
ReaderDataConnectors Two6-pinterminalblockssupportingRS485andWiegandprotocolsforcommunicationwiththe reader.Forspecications,seepage22.
ReaderI/OConnectors Two6-pinterminalblocksforreaderinputandoutput.Inadditiontothe0VDCreferencepoint andpower(DCoutput),thereaderI/Oconnectorprovidestheinterfaceto:
•Digitalinput–Forconnecting,forexample,readertamperingalarms.
•Digitaloutput–Forconnecting,forexample,readerbeepersandreaderLEDs.
Forspecications,seepage23.
18
AXISA1001NetworkDoorController
DoorConnectors Two4-pinterminalblocksforconnectingdoormonitoringdevicesandrequesttoexit(REX)devices. Forspecications,seepage24.
AuxiliaryConnector 4-pincongurableI/Oterminalblock.Usewithexternaldevices,incombinationwith,forexample tamperingalarms,eventtriggeringandalarmnotications.Inadditiontothe0VDCreference pointandpower(DCoutput),theauxiliaryconnectorprovidestheinterfaceto:
•Digitalinput–Analarminputforconnectingdevicesthatcantogglebetweenanopen
andclosedcircuit,forexamplePIRsensorsorglassbreakdetectors.
•Digitaloutput–Forconnectingexternaldevicessuchasburglaralarms,sirensorlights.
ConnecteddevicescanbeactivatedbytheVAPIX®applicationprogramminginterfaceor byanactionrule.
Forspecications,seepage25.
ExternalPowerInputs
NO
TICE
NO NO
TICE TICE
Theproductshallbeconnectedusingashieldednetworkcable(STP).Allcablesconnecting theproducttothenetworkshallbeintendedfortheirspecicuse.Makesurethatthe networkdevicesareinstalledinaccordancewiththemanufacturer’sinstructions.For informationaboutregulatoryrequirements,seeElectromagneticcompatibility(EMC)on page4.
PowerConnector 2-pinterminalblockforDCpowerinput.UseaSafetyExtraLowVoltage(SELV)compliantlimited powersource(LPS)witheitheraratedoutputpowerlimitedto≤100Woraratedoutputcurrent limitedto≤5A.Forspecications,seepage25.
EN
NetworkConnector RJ45Ethernetconnector.SupportsPoweroverEthernet(PoE).Forspecications,seepage26.
PowerOutputs
PowerLockConnector
4-pinterminalblockforconnectingoneortwolocks.Thelockconnectorcanalsobeusedtopower externaldevices.Forspecications,seepage26.
Power&RelayConnector
6-pinterminalblockforconnectingpowerandthedoorcontroller’srelaytoexternaldevicessuch aslocksandsensors.Forspecications,seepage27.
19
AXISA1001NetworkDoorController
ButtonsandOtherHardware
TamperingAlarmPinHeader Two2-pinheadersfordisconnectingthefrontandbacktamperingalarms.Forspecications, seepage27.
ControlButton Thecontrolbuttonisusedfor:
•Resettingtheproducttofactorydefaultsettings.Seepage45.
•ConnectingtoanAXISVideoHostingSystemserviceorAXISInternetDynamicDNS Service.Formoreinformationabouttheseservices,seetheUserManual.
Specications
OperatingConditions
TheAxisproductisintendedforindooruse.
Classication
IEC60721-4-3Class3K3, 3M3
TemperatureHumidity
0°Cto50°C (32°Fto122°F)
20–85%RH(non-condensing)
PowerConsumption
NO
TICE
NO NO
TICE TICE
UseaSafetyExtraLowVoltage(SELV)compliantlimitedpowersource(LPS)witheithera ratedoutputpowerlimitedto100Woraratedoutputcurrentlimitedto≤5A.
PowersupplyMaximumloadonoutputs
PoweroverEthernetIEEE802.3af/802.3atType1Class3, 44–57VDC
10–30VDC,max26W
PowerOutputConversion(WtoA)
IfthedeviceconnectingtotheAxisproductonlyhasanampere(A)rating,thefollowingmethod canbeusedforconversiontowatts(W).
ThetotalmaximumoutputloadoftheAxisproductdependsonthepowersource:
7.5W
14W
20
AXISA1001NetworkDoorController
PowersourceTotalmaximumloadonoutputs
PoweroverEthernetIEEE802.3af/802.3atType1Class3 10–30VDC
ThevoltageontheAxisproduct’spoweroutputsis12VDC(exceptfortheAuxiliaryConnector whichhasavoltageof3.3VDC).Ifyourconnectingdevicehasamaximumampereratingoffor example0.3A,thefollowingconversiongivesthepowerinwatts(W):
Power(W)=Voltage(V)xCurrent(I)
Power=12x0.3=3.6W
Thefollowingtableshowstheavailablepowerafterconnectionofthe0.3Adeviceintheexample.
PowersourceAvailablepower
PoweroverEthernetIEEE802.3af/802.3atType1Class3 10–30VDC
TheDCoutputonthefollowingconnectorsareconsideredaspoweroutputs:‘
7.5W
14W
7.5–3.6=3.9W
14–3.6=10.4W
EN
•PowerLockConnector
•Power&RelayConnector
•ReaderI/OConnector
•AuxiliaryConnector
NO
TICE
NO NO
TICE TICE
Thepoweroutputoftheauxiliaryconnectorhasa3.3VDCvoltagerating.
Forconnectorspecications,seePowerConnectoronpage25andNetworkConnectoronpage26.
PerformanceLevelsforAccessControl
ThissectioncontainsperformancelevelinformationrequiredforUL294compliance.
FeatureLevel
DestructiveAttackTestI LineSecurity
I
21
AXISA1001NetworkDoorController
EnduranceIV StandbyPower
WireArea
NO
TICE
NO NO
TICE TICE
Eachwireshallhaveanconductorcross-sectionalareathatcorrespondstoanconductor gaugerangeofAWG28–16(CSA)orAWG22–14(cUL/UL).Selectcablesincompliance withyourlocalregulations.
I
AWG
28–16
22–14
Diametermm(in)
0.321–1.29(0.0126–0.0508)
0.644–1.63(0.0253–0.0641)
Areamm
0.0810–1.31
0.326–2.08
2
Connectors
Forinformationabouttheconnectors’positions,seeHardwareoverviewonpage15.
Forconnectiondiagramsandinformationaboutthehardwarepinchartgeneratedthroughthe hardwareconguration,seeConnectionDiagramsonpage28andCongurethehardwareon page42.
Thefollowingsectiondescribestheconnectors’technicalspecications.
ReaderDataConnector
6-pinterminalblocksupportingRS485andWiegandprotocolsforcommunicationwiththereader.
TheRS485portssupport:
•Two-wireRS485halfduplex
•Four-wireRS485fullduplex
TheWiegandportssupport:
•Two-wireWiegand
22
AXISA1001NetworkDoorController
FunctionPinNotes
RS485
RS485
Wiegand
Important
TheRS485portshaveaxedbaudrateof9600Bit/s.
Important
Therecommendedmaximumcablelengthis30m(98.4ft).
Important
TheoutputcircuitsinthissectionareClass2powerlimited.
ReaderI/OConnector
6-pinterminalblockfor:
•Auxiliarypower(DCoutput)
•DigitalInput
•DigitalOutput
•0VDC(-)
Pin3onthereaderI/Oconnectorscanbesupervised.Iftheconnectionisinterrupted,aneventis activated.Tousesupervisedinputs,installendoflineresistors.Usetheconnectiondiagram forsupervisedinputs.Seepage29.
A­B+ A­B+
D0(Data0)
D1(Data1)
1
2 3 4 5
6
ForfullduplexRS485 ForhalfduplexRS485
ForfullduplexRS485 ForhalfduplexRS485
ForWiegand
EN
FunctionPinNotes
0VDC(-) DCoutput
1
2
Forpoweringauxiliaryequipment. Note:Thispincanonlybeusedas powerout.
23
Specications
0VDC
12VDC Maxload=300mA
AXISA1001NetworkDoorController
Congurable (Inputor Output)
Important
Therecommendedmaximumcablelengthis30m(98.4ft).
Important
TheoutputcircuitsinthissectionareClass2powerlimited.
DoorConnector
Two4-pinterminalblocksfordoormonitoringdevices(digitalinput).
Alldoorinputpinscanbesupervised.Iftheconnectionisinterrupted,analarmistriggered.To usesupervisedinputs,installendoflineresistors.Usetheconnectiondiagramforsupervised inputs.Seepage29.
3–6
Digitalinput—Connecttopin1to activate,orleaveoating(unconnected) todeactivate.
Digitaloutput—Connecttopin1to activate,orleaveoating(unconnected) todeactivate.Ifusedwithaninductive load,e.g.arelay,adiodemustbe connectedinparallelwiththeload,for protectionagainstvoltagetransients.
0tomax40VDC
0tomax40VDC,open drain,100mA
FunctionPinNotes
0VDC(-) Input
Important
Therecommendedmaximumcablelengthis30m(98.4ft).
1,3
2,4
Forcommunicatingwithdoormonitor. Digitalinput—Connectto pin1or3respectivelytoactivate, orleaveoating(unconnected)to deactivate. Note:Thispincanonlybeusedfor input.
Specications
0VDC
0tomax40VDC
24
AXISA1001NetworkDoorController
AuxiliaryConnector
4-pincongurableI/Oterminalblockfor:
•Auxiliarypower(DCoutput)
•DigitalInput
•DigitalOutput
•0VDC(-)
Foranexampleconnectiondiagram,seeConnectionDiagramsonpage28.
FunctionPinNotes
0VDC(-) DCoutput
Congurable (Inputor Output)
1
2
3–4
Forpoweringauxiliaryequipment. Note:Thispincanonlybeusedas powerout.
Digitalinput—Connecttopin1to activate,orleaveoating(unconnected) todeactivate.
Digitaloutput—Connecttopin1to activate,orleaveoating(unconnected) todeactivate.Ifusedwithaninductive load,e.g.arelay,adiodemustbe connectedinparallelwiththeload,for protectionagainstvoltagetransients.
EN
Specications
0VDC
3.3VDC Maxload=100mA
0tomax40VDC
0tomax40VDC,open drain,100mA
Important
Therecommendedmaximumcablelengthis30m(98.4ft).
Important
TheoutputcircuitsinthissectionareClass2powerlimited.
PowerConnector
2-pinterminalblockforDCpowerinput.UseaSafetyExtraLowVoltage(SELV)compliantlimited powersource(LPS)witheitheraratedoutputpowerlimitedto≤100Woraratedoutputcurrent limitedto≤5A.
25
AXISA1001NetworkDoorController
FunctionPinNotes
0VDC(-) DCinput
NetworkConnector
RJ45Ethernetconnector.UseCategory5ecablesorhigher.
Function
PowerandEthernet
Powerlockconnector
4-pinterminalblockforpoweringoneortwolocks(DCoutput).Thelockconnectorcanalso beusedtopowerexternaldevices.
Connectlocksandloadstothepinsaccordingtothehardwarepinchartgeneratedthroughthe hardwareconguration.
1
2
Forpoweringcontrollerwhennotusing PoweroverEthernet. Note:Thispincanonlybeusedas powerin.
Specications
PoweroverEthernetIEEE802.3af/802.3atType1Class3, 44–57VDC
Maxloadonoutputs=7.5W
Specications
0VDC
10–30VDC,max26W Maxloadonoutputs= 14W
FunctionPinNotes
0VDC(-) 0VDC,
oating,or 12VDC
1,3
2,4
Forcontrollinguptotwo12Vlocks.Use thehardwarepinchart.SeeCongure thehardwareonpage42.
26
Specications
0VDC
12VDC Maxtotalload=500mA
AXISA1001NetworkDoorController
NO
TICE
NO NO
TICE TICE
Ifthelockisnon-polarized,werecommendyoutoaddanexternalybackdiode.
Important
TheoutputcircuitsinthissectionareClass2powerlimited.
Power&relayconnector
6-pinterminalblockwithbuilt-inrelayfor:
•Externaldevices
•Auxiliarypower(DCoutput)
•0VDC(-)
Connectlocksandloadstothepinsaccordingtothehardwarepinchartgeneratedthroughthe hardwareconguration.
EN
FunctionPinNotes
0VDC(-) Relay
12VDC
24VDC
NO
TICE
NO NO
TICE TICE
Ifthelockisnon-polarized,werecommendyoutoaddanexternalybackdiode.
Important
TheoutputcircuitsinthissectionareClass2powerlimited.
TamperingAlarmPinHeader
Two2-pinheadersforbypassing:
1,4
2–3
5
6
Forconnectingrelaydevices.Usethe hardwarepinchart.SeeCongurethe hardwareonpage42. Thetworelaypinsaregalvanically separatedfromtherestofthecircuitry.
Forpoweringauxiliaryequipment. Note:Thispincanonlybeusedas powerout.
Notused
27
Specications
0VDC
Maxcurrent=700mA Maxvoltage=+30VDC
Maxvoltage=+12VDC Maxload=500mA
AXISA1001NetworkDoorController
•Backtamperingalarm(TB)
•Fronttamperingalarm(TF)
FunctionPinNotes
Backtamperingalarm Fronttampering
alarm
Note
Boththefrontandbacktamperingalarmsareconnectedbydefault.Thecasingopen triggercanbeconguredtoperformanactionifthedoorcontrollerisopenedorifthe doorcontrollerisremovedfromthewallorceiling.Forinformationabouthowtocongure alarmsandevents,seetheUserManual.
1–2 1–2
ConnectionDiagrams
Connectdevicesaccordingtothehardwarepinchartgeneratedthroughthehardware conguration.Formoreinformationabouthardwarecongurationandthehardwarepinchart,see Congurethehardwareonpage42.
Tobypassthefrontandbacktamperingalarm simultaneously,connectjumpersbetweenTB1,TB2and TF1,TF2respectively.Bypassingthetamperingalarms meansthatthesystemwillnotidentifyanytampering attempts.
28
AXISA1001NetworkDoorController
AuxiliaryConnector
EN
1
0VDC(-)
2
DCoutput:3.3V,max100mA
A
I/Oconguredasinput
B
I/Oconguredasoutput
SupervisedInputs
Tousesupervisedinputs,installendoflineresistorsaccordingtothediagrambelow.
iInput
ii
0VDC(-)
29
AXISA1001NetworkDoorController
Note
Itisrecommendedtousetwistedandshieldedcables.Connectshieldingto0VDC.
Installthehardware
CAUTION
NevermounttheAxisproductwhilepowerisappliedtotheproduct.Alwaysapplypower attheendoftheinstallation.
NO
TICE
NO NO
TICE TICE
Toprotectthecircuitsagainstelectrostaticdischarge(ESD),useESDprotectionwhen handlingtheproductwhilethecomponentsandcontactsareexposed.
Readalltheinstructionsbeforeinstallingtheproduct.
•Tocongurethehardware,seepage42.
•Toinstalltheproductonawall(preferred)orceiling,seepage31.
•ToinstalltheproductonaDINrail,seepage32.
•Toconnectthecables,seepage33.
SystemConsiderations
TheAxisproductshallbeinstalledwithinthesecuredarea.
TheAxisproduct,whetheritisinstalledasasingledoorcontrollerorinasystemofdoorcontrollers, shallnotlimitorweakentheintendeduseofthedevicesconnectedtoit.
TheAxisproductshouldbeinstalledonawall(preferred)oraceiling,withorwithoutajunction box.ItcanalsobeinstalledonaDINrail.
Systemsize
TheAxisproductcanbeconnectedtootherAxisNetworkDoorControllersinacontrollercluster thatcanhandleupto66doorsorwirelessdevices(withinthecluster).EachAxisproductcan connectuptotwowireddoorsoronewireddoortogetherwithonewirelessgateway.Theamount ofwirelesslocksconguredtoeachgatewayisdependentonthemanufacturer.
Note
•WirelesslocksarenotsoldanddistributedbyAxisCommunications.Forsupportand
trainingrelatedtowirelesssystems,contactrelevantmanufacturers'partner.
•TheAxisproductisconsideredstandalone,anddoesnotrequireconstantconnectiontoa
computerforproperoperation.Theuseofaconnectedcomputerisforlocalprogramming, downloading,andsupplementalmonitoringpurposesonly.
30
Loading...
+ 184 hidden pages