AXIS A1001 installation with
24 volt lock
Application
>
One-door solution with 24 V lock
READER DATA 1
A- B+ A- B+ D0 D1
READER I/O 1
12
IO
-
V
3IO4IO5IO6
DC IN
- +
AUDIO
+MIC- +SPK-
DOOR IN 1 DOOR IN 2
- IN1 - IN2 - IN3 - IN4
AUX
- 3V
IO1IO
2
READER I/O 2
IO7IO8IO9IO
12
-
V
LOCK
- H1 - H2
10
READER DATA 2
A- B+ A- B+ D0 D1
RELAY | PWR
*REL*- -
12
V24V
High PoE Switch (802.3at)
AXIS T8127 60 W Splitter
12/24 V DC
+
-
AXIS Entry Manager
Programming
1. Congure Lock 1 for Relay
Lock 1:
12 V
Relay
2. Depending on your lock type, congure
Lock 1 Relay for
Relay open = Locked for a fail-secure lock
Relay open = Unlocked for a fail-safe lock
Relay
3. Wire the RELAY|PWR connector according
to the drawing
Relay open = Locked
Relay open = Locked
Relay open = Unlocked
24 volt lock
Lock 1
Adhere to local life safety code in all installations.
Ensure that your power supplies and relays are rated for the intended purposes.
Illustration does not depict cabling for reader, REX, Door monitor, battery backup and UPS.

AXIS A1001 installation with
dual electric strikes
Application
>
Simple two-door solution with one door
using external power
READER DATA 1
A- B+ A- B+ D0 D1
READER I/O 1
12
IO
-
V
3IO4IO5IO6
DC IN
- +
AUDIO
+MIC- +SPK-
DOOR IN 1 DOOR IN 2
- IN1 - IN2 - IN3 - IN4
AUX
- 3V
IO1IO
2
READER I/O 2
IO7IO8IO9IO
12
-
V
LOCK
- H1 - H2
10
READER DATA 2
A- B+ A- B+ D0 D1
RELAY | PWR
*REL*- -
12
V24V
PoE Switch
Door Power Supply
12/24-
12/24+
AXIS Entry Manager
Programming
1. Congure Lock 1 for 12 V and Fail-secure
Lock 1:
12 V
2. Congure Lock 2 for Relay
Lock 2:
12 V
Relay
3. Depending on your lock type, congure
Lock 2 Relay for
Relay open = Locked for a fail-secure lock
Relay open = Unlocked for a fail-safe lock
Relay
Fail-secure
Relay open = Locked
Relay open = Locked
Relay open = Unlocked
12 volt DC
Electric Strike
Lock 1 Lock 2
Adhere to local life safety code in all installations.
Ensure that your power supplies and relays are rated for the intended purposes.
Illustration does not depict cabling for reader, REX, Door monitor, battery backup and UPS.
12/24 volt DC
Electric Strike
Voltage is determined by the power supply voltage out.
4. Wire the LOCK connector and the
RELAY|PWR connector according to
the drawing

AXIS A1001 installation with dual
locks and external power supply
Application
>
Two-door solution with high current locks
>
Suggested for use with existing power and
relay
READER DATA 1
A- B+ A- B+ D0 D1
POS+
NEG-
C
NC
NO
Relay
READER I/O 1
12
IO
-
V
3IO4IO5IO6
DC IN
- +
C
NC
NO
AUDIO
+MIC- +SPK-
DOOR IN 1 DOOR IN 2
- IN1 - IN2 - IN3 - IN4
AUX
- 3V
IO1IO
2
READER I/O 2
IO7IO8IO9IO
12
-
V
LOCK
- H1 - H2
10
READER DATA 2
A- B+ A- B+ D0 D1
RELAY | PWR
*REL*- -
12
V24V
PoE Switch
Door Power Supply
12/24-
12/24+
12/24+
12/24-
AXIS Entry Manager
Programming
1. Congure Lock 1 for 12 V and Fail-secure
Lock 1:
12 V
2. Congure Lock 2 for Relay
Lock 2:
12 V
Relay
3. Depending on your lock type, congure
Lock 2 Relay for
Relay open = Locked for a fail-secure lock
Relay open = Unlocked for a fail-safe lock
Relay
Fail-secure
Relay open = Locked
Relay open = Locked
Relay open = Unlocked
Electric Strike
Lock 1 Lock 2
Adhere to local life safety code in all installations.
Ensure that your power supplies and relays are rated for the intended purposes.
Illustration does not depict cabling for reader, REX, Door monitor, battery backup and UPS.
12/24 volt DC12/24 volt DC
Electric Strike
The AXIS A1001 lock output connects to the separate auxiliary
relay power input. 12/24 volts DC+ from a separate door power
supply connects to the C terminal of the slave relay. This transfers
to the NO terminal, pushing power to the lock.
4. Wire the LOCK connector and the
RELAY|PWR connector according to
the drawing