Installation and removal of the PoE Midspan must be carried out
by qualified personnel only.
AC Power Cord Set:
• The power cord must have regulatory agency approval for the
specific country in which it is used (i.e., UL, CSA, VDE, etc.).
• The power cord must be a three-conductor type (two current
carrying conductors; one ground conductor) terminated on
one end by an IEC 60320 appliance coupler (for connection to
the PoE Midspan), and on the other end by a plug containing a
ground (earthing) contact.
• The power cord must be rated for a minimum of 250Vac RMS
operation, with a minimum rated current capacity of 5 amps
(or a minimum wire gauge of 18 AWG (0.75mm
Note: PoE Midspan units installed in Australia require power
cords with a minimum wire gauge of 16 AWG (1.0 mm
• The AC wall socket-outlet must be near the PoE Midspan and
easily accessible. You can remove AC power from the PoE
Midspan by disconnecting the AC power cord from either the
wall socket-outlet or the PoE Midspan appliance coupler.
• The PoE Midspan data and data/power interfaces are qualified
as SELV (Safety Extra-Low Voltage) circuits according to IEC
60950. These interfaces can only be connected to SELV
interfaces on other equipment.
2
)).
2
).
WARNINGS!
• Read the installation instructions before connecting the PoE
Midspan to its power source.
• Follow basic electricity safety measures whenever connecting
the PoE Midspan to its power source.
• This product relies on the building installation for short-circuit
(over current) protection. Ensure that a fuse or circuit breaker
no larger than 120 VAC, 3A. U.S. (240 VAC, 1.5A international)
is used on the phase conductor.
• A voltage mismatch can cause equipment damage and may
pose a fire hazard. If the voltage indicated on the label is
different from the power outlet voltage, do not connect the
PoE Midspan to this power outlet.
The PoE Midspan "Data In" and "Data & Power Out" ports are
shielded RJ-45 data sockets. They cannot be used as Plain Old
Telephone Service (POTS) telephone sockets. Only RJ-45 data
connectors may be connected to these sockets.
Information de Seguridad
La instalación y desinstalación del Midspan POE debe ser llevada
a cabo solamente por personal técnico calificado.
Colocación de cables de alimentación AC:
• El cabe de alimentación debe estar aprobado por la autoridad
reguladora correspondiente, en país en el cual es usado (por
ejemplo UL, CSA, VDE, etc.).
• El cabe de alimentación debe ser del tipo triple conductor (dos
conductores de corriente y conductor de tierra) terminado en
un dispositivo para acoplado IEC 60320 (para la conexión al
Midspan POE), y otro que contiene contacto de conexión a
tierra.
• El cabe de alimentación debe ser de un mínimo de 250V AC
operación RMS, con una certificación de mínimo de 5 Amper
(o mínimo un cable de18 AWG (0.75mm2)).
• Nota: Las unidades Midspan POE instaladas en Australia
requieren de un cable de alimentación con un mínimo de 16
AWG (1.0 mm2).
• El enchufe de pared para cable de alimentación AC debe estar
cerca del Midspan POE para un fácil acceso. La alimentación
AC puede ser cortada del Midspan POE bien desconectado el
enchufe de la pared o desconectando el cable del Midspan
POE.
• Las interfaces de data y data/alimentación están homologadas
como circuitos SELV (Safety Extra-Low Voltage) de acuerdo a
IEC 60950. Estas interfaces solamente pueden ser conectadas
a SELV interfaces en otros dispositivos.
AVISOS!
• Lea las instrucciones de instalación antes de conectar la
alimentación al Midspan POE.
• Siga las medidas básicas de seguridad siempre que este
manipulando la alimentación eléctrica del Midspan POE.
• Este producto esta basado en la generación cortacircuitos de
protección. Asegúrese de usar fusibles o cortacircuitos no
mayores a 120 V CA, 3A. U.S (240 VCA, 1.5A internacional)
usados como conductores fases.
• Un voltaje equivocado puede causa el daño del dispositivo y
acarrar peligro de incendio. Si el voltaje indicado en la
etiqueta es diferente al voltaje en el enchufe eléctrico, no
conecte el PoE Midspan
Los puertos de entrada data y salida data/alimentación son
conectores RJ-45. Los antiguos cables de teléfono (POTS) no
pueden ser usados. Solamente conectores de red RJ-45 pueden
ser contactados a estos puertos de entrada de entrada data y
salida data/alimentación.
EMC Compliance
A Category 5 foiled twisted-pair cable must be used to ensure
compliance with requirements of FCC Part 15, subpart B, Class B.
The use of unshielded cables (Category 5 for 10BASE T ports or
for 100BASE Tx ports) complies with Class A requirements.
Notice
Axis’ policy is to improve its products as new technology,
components, software, and firmware become available. Axis,
therefore, reserves the right to change specifications without
prior notice.
Trademarks
The product described in this guide is a licensed product of
PowerDsine.
Support
Should you require any technical assistance, please contact your
Axis reseller. If your questions cannot be answered immediately,
your reseller will forward your queries through the appropriate
channels to ensure a rapid response. If you are connected to the
Internet, you can:
• download user documentation
• find answers to resolved problems in the FAQ database. Search
by product, category, or phrases
• report problems to Axis support by logging in to your private
support area.
AXIS AX-3001 PoE Midspan 1-PortPage 3
AXIS AX-3001 Installation Guide
The Power over Ethernet (PoE) Midspan adds 48V DC to unused (non-data) wires (Mode B) in a
standard Category 5 Ethernet cable. As a result, the PoE Midspan delivers both data and power to
the terminal. The device is designed to meet the IEEE802.3af standard.
Preliminary Steps
• Ensure AC power is applied to the PoE Midspan using an operational AC cable with an
appropriate ground connection.
• Ensure that output Ethernet cable is connected to the Data & Power Out port.
• Verify that a power ready Ethernet compatible device is connected.
Note:
Do not use a cross over cable between the PoE Midspan output port and the load device.
Installation
Note the following before mounting the PoE Midspan to a fixed location:
• The PoE Midspan may be wall or bench mounted using the rear side holes.
• Do not to cover the PoE Midspan or block the airflow to the PoE with any foreign objects.
Keep the PoE Midspan away from excessive heat and humidity, and keep it free from vibration and dust
• Ensure that the cable length from the Ethernet network source to the terminal does not
exceed 100 meters (333 Feet). The PoE is not a repeater and does not amplify the Ethernet
data signal
• Use a splitter if desired; ensure that the splitter is connected close to the terminal and not
on the Midspan
• There is no "on-off" switch, simply plug the PoE Midspan to an AC power source
ENGLISH
Installing the Unit
1. Connect the PoE Midspan to an AC outlet (100-240 VAC), using a standard power cable.
2. Connect the unit Data In jack (input) to the remote Ethernet network switch Patch panel.
3. Connect the Data & Power Out jack (output) to the terminal.
Page 4AXIS AX-3001 PoE Midspan 1-Port
Data in
AC Input connectivity
Output Port Input port
CAT 5 Cable
Data & Power out
indicator
Port connectivity
indicator
Terminal Ethernet
Hardware overview
Indicators
LEDAC (Main)Port
Green
Green (blinking)
Indicates that the power is on
(Power is active)
Output voltage is out of rangeOverload or short circuit
Indicates that a remote terminal is
connected
Specifications
Environmental specifications
Electrical specifications
Ethernet Interface
ModeTemperatureHumidity
Operating
Storage
Input voltage90 to 264V AC (47-63 Hz)
Input current0.5A (max)
Minimum Available Output Power15.4W
Nominal Output Voltage45 to 56V DC
Input (Data In):
Ethernet 10/100Base-T
Output (Data & Power Out):
Ethernet 10/100Base-T, plus 48 VDC
0 - 40°C
32 to 104°F10 to 90%
-20 to 70°C
-4 to 158°F
RJ 45 female socket
RJ 45 female socket, with DC voltage on wire pairs 7-8 and 4-5.
(no condensation allowed)
AXIS AX-3001 PoE Midspan 1-PortPage 5
Troubleshooting
SymptomCorrective Steps
Midspan does not
power up
A port indicator is
not lit and the PD
does not operate
The end device
operates, but there
is no data link
1. Verify that an approved power cord is used.
2. Verify that the voltage at the power inlet is between 100 and 240V AC.
3. Remove and re-apply power to the device and check the indicators during power up
sequence.
1. The Midspan did not detect a PD and therefore the port is not enabled.
2. Verify that the PD is designed for PoE operation
3. Verify that you are using a standard Category 5/5e/6, straight-wired cable, with
four pairs
4. If there is a connected external power splitter, replace it to verify that it is
functioning properly
5. Ensure that the input Ethernet cable is connected to the Data In port
6. Verify that the PD is connected to the Data & Power port.
7. Try to reconnect the same PD into a different Midspan. If it works, there is probably
a faulty port or RJ-45 connection.
8. Verify that there is no short over any of the twisted pair cables or over the RJ45
connectors.
1. Verify that the port indicator on the front panel is continuously lit.
2. If an external power splitter is in use, replace it with a known-good splitter.
3. Verify that for this link, you are using standard UTP/FTP Category 5 straight (noncrossover) cabling, with all four pairs.
4. Verify that the Ethernet cable length is less than 100 meters from the Ethernet
source to the load/remote terminal.
5. Try to reconnect the same PD into a different Midspan. If it works, there is probably
a faulty port or RJ-45 connection.
ENGLISH
AXIS AX-3001 PoE Midspan 1-PortPage 7
AXIS AX-3001 Guide d’installation
L’injecteur Power over Ethernet (PoE) ajoute 48 V CC aux fils (ne servant pas à la transmission des
données) non utilisés (en Mode B) d’un câble Ethernet standard de catégorie 5. L’injecteur PoE peut
donc alimenter le terminal aussi bien en données qu’en électricité. Il est conforme à la norme
IEEE802.3af.
Étapes préliminaires
• Vérifiez que l’injecteur PoE est raccordé à un câble CA en bon état de fonctionnement et
correctement mis à la terre.
• Vérifiez que le câble Ethernet de sortie est branché sur le port de données et d’alimentation
(sortie).
• Vérifiez qu’un périphérique compatible Ethernet prêt à être branché est connecté.
Note:
N’utilisez pas de câble simulateur de modem entre le port de sortie de l’injecteur PoE et le
périphérique de charge.
Installation
Veuillez prendre note de ce qui suit avant de poser l’injecteur PoE à un endroit fixe :
FRAN
Ç
AIS
• L’injecteur PoE peut être fixé au mur ou sur une surface plate à l’aide des trous situés au
dos de l’appareil.
• Ne recouvrez pas l’injecteur PoE et ne bloquez pas son système d’aération par des corps
étrangers. Conservez l’injecteur PoE à l’abri des excès de la chaleur et de l’humidité, des
vibrations et de la poussière.
• Veillez à ce que la longueur de câble entre la source du réseau Ethernet et le terminal ne
dépasse pas 100 mètres. Le PoE n’est pas un répéteur et il n’amplifie pas le signal des données Ethernet.
• Utilisez un diviseur si vous le souhaitez, en veillant à ce qu’il soit branché à proximité du
terminal et non sur l’injecteur.
• Il n’y a pas d’interrupteur Marche/Arrêt. Il suffit donc de brancher l’injecteur PoE sur une
prise de courant CA pour le mettre en marche.
Installation de l’injecteur
1. Branchez l’injecteur PoE sur une prise CA (100-240 V CA), à l’aide d’un câble ordinaire.
2. Branchez le connecteur Données d’entrée (entrée) de l’appareil sur le tableau de connexions du
commutateur réseau Ethernet distant.
3. Branchez le connecteur Données et alimentation de sortie (sortie) sur le terminal.
Page 8AXIS AX-3001 PoE Midspan 1-Port
Données d’entrée
Indicateur de
Port de sortie
Port d’entrée
Câble de cat. 5
Données et
Indicateur de
Terminal Ethernet
connexion d’entrée CA
connexion du port
alimentation de sortie
Vue d’ensemble du matériel
Indicateurs
DELCA (secteur)Port
Vert
Vert
clignotant
Indique que l’appareil est sous tension
(alimenté en courant).
La tension de sortie est hors limites.Surcharge ou court-circuit
Indique qu’un terminal distant est
connecté.
Caractéristiques techniques
Caractéristiques environnementales
ModeTempératureHumidité
En fonctionnement
En stockage
0 à 40 °C
32 à 104 °F10 à 90 %
-20 à 70 °C
-4 à 158 °F
(condensation non autorisée)
Caractéristiques électriques
Tension d’entrée90 à 264 V CA (47-63 Hz)
Courant d’entrée0,5 A (max.)
Puissance de sortie disponible minimum15,4 W
Tension de sortie nominale45 à 56 V CC
Interface Ethernet
Entrée (données d’entrée) :
Ethernet 10/100Base-T
Sortie (données et alimentation de sortie) :
Ethernet 10/100Base-T, plus 48 V CC
Connecteur femelle RJ45
Connecteur femelle RJ45, avec tension
CC sur les paires de fils 7-8 et 4-5.